An integrated sequential injection analysis system for ammonium determination in recycled hygiene and potable water samples for future use in manned space missions

被引:16
作者
Giakisikli, Georgia [1 ]
Trikas, Evangelos [1 ]
Petala, Maria [2 ]
Karapantsios, Theodoros [3 ]
Zachariadis, Georgios [1 ]
Anthemidis, Aristidis [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Lab Analyt Chem, Grp Automated & Multielemental Methods Anal AMG, Thessaloniki, Greece
[2] Aristotle Univ Thessaloniki, Dept Civil Engn, Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Dept Chem, Lab Gen & Inorgan Chem Technol, Multiphase Dynam Grp, Thessaloniki, Greece
关键词
Trade off methodology; Sequential injection analysis; Ammonium determination; Fluorimetiy; Microgravity; International space station; GAS-DIFFUSION; FLUORESCENCE DETECTION; SEAWATER; ESTUARINE; ANALYZER; COASTAL;
D O I
10.1016/j.microc.2017.04.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated method for on-line ammonium determination in recycled water produced on board the International Space Station was developed and optimized. A trade off methodology is presented to evaluate and select the most appropriate analytical system, adaptable to space flight requirements. A sequential injection system meets the specifications for on-line monitoring in space conditions as it is an integrated flow manifold with small dimensions operating in a totally closed loop preventing any contact or release of the fluids/gases inside the space environment. The method is based on the reaction between ammonia and o-phthaldialdehyde in the presence of sulfite in alkaline media (pH ca. 11). The fluorescent product (isoindol-1-sulfonate) is then quantified at 425 nm. The influence of chemical and flow variables as well as space adaptation characteristics which affect the performance of the system if placed on board the International Space Station have been studied, providing the appropriate conditions for the analysis of real samples. For a total analysis time of 174 s, a detection limit (3s) of 0.018 mg L-1 for NF4+ was obtained along with a sampling frequency of 20 h(-1). The working range was at values between 0.06 and 4.00 mg L-1 NH4+. The "antra-day precision" was 230% (at 0.50 mg L-1), while the "inter-day precision" was 2.40% (at 0.50 mg L-1). The accuracy of the proposed method was evaluated by analyzing standard reference materials as well as using the certified method (indophenol blue) for ammonium determination. The method was successfully applied for ammonium determination in water samples obtained by the Water Treatment Unit Breadboard (WTUB) located in Antarctica Concordia Research Station. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:490 / 495
页数:6
相关论文
共 28 条
[1]   A membraneless gas-diffusion unit - multisyringe flow injection spectrophotometric method for ammonium determination in untreated environmental samples [J].
Almeida, M. Ines G. S. ;
Manuel Estela, Jose ;
Segundo, Marcela A. ;
Cerda, Victor .
TALANTA, 2011, 84 (05) :1244-1252
[2]  
American Public Health Association American Water Works Association, 1999, STANDARD METHODS EXA
[3]   Shipboard fluorometric flow analyzer for high-resolution underway measurement of ammonium in Seawater [J].
Amornthammarong, Natchanon ;
Zhang, Jia-Zhong .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1019-1026
[4]   Rapid, low level determination of silver(I) in drinking water by colorimetric-solid-phase extraction [J].
Arena, MP ;
Porter, MD ;
Fritz, JS .
ANALYTICA CHIMICA ACTA, 2003, 482 (02) :197-207
[5]   Analytical chemistry in water quality monitoring during manned space missions [J].
Artemyeva, Anastasia A. .
ACTA ASTRONAUTICA, 2016, 126 :11-17
[6]   MANUAL DETERMINATION OF AMMONIA IN FRESH WATERS USING AN AMMONIA-SENSITIVE MEMBRANE-ELECTRODE [J].
BECKETT, MJ ;
WILSON, AL .
WATER RESEARCH, 1974, 8 (06) :333-340
[7]  
Bruzzonitia M. C., 2003, ANAL CHIM ACTA, V482, P197
[8]   Biparametric potentiometric analytical microsystem for nitrate and potassium monitoring in water recycling processes for manned space missions [J].
Calvo-Lopez, Antonio ;
Arasa-Puig, Eva ;
Puyol, Mar ;
Manel Casalta, Joan ;
Alonso-Chamarro, Julian .
ANALYTICA CHIMICA ACTA, 2013, 804 :190-196
[9]   A fast sequential injection analysis system for the simultaneous determination of ammonia and phosphate [J].
Frank, C ;
Schroeder, F ;
Ebinghaus, R ;
Ruck, W .
MICROCHIMICA ACTA, 2006, 154 (1-2) :31-38
[10]   Spectrophotometric determination of ammonia in estuarine waters by hybrid reagent-injection gas-diffusion flow analysis [J].
Gray, Sarah M. ;
Ellis, Peter S. ;
Grace, Michael R. ;
McKelvie, Ian D. .
SPECTROSCOPY LETTERS, 2006, 39 (06) :737-753