Stability of mercury-coated platinum microelectrodes upon touching a solid surface in scanning electrochemical microscopy (SECM) experiments

被引:17
作者
Ciani, I [1 ]
Daniele, S [1 ]
Bragato, C [1 ]
Baldo, MA [1 ]
机构
[1] Univ Venice, Dept Chem Phys, I-30123 Venice, Italy
关键词
sphere-caps; mercury microelectrodes; SECM; approach curves; contact voltammetry;
D O I
10.1016/S1388-2481(03)00068-7
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The features of experimental approach curves, recorded in scanning electrochemical microscopy measurements, and acquired with a series of sphere-cap tips while approaching a solid insulating substrate, are examined in detail. Sphere-caps are prepared by electrodeposition of liquid mercury onto a platinum microdisk substrate 10 mum radius, and having RG=R/a=10 (R is total tip dimension, which includes the shield thickness and the electrode radius a). From the data obtained, it is established that sphere caps with aspect ratio h/a>0.3 (h is the sphere cap height) are able to touch, or even be squeezed against the surface of the solid substrate. Under these latter conditions, for the sphere caps, the negative feedback process at low tip-substrate distances, is more pronounced than that of the corresponding naked microdisk. A good tip stability and no mercury loss is observed upon touching the substrate for sphere caps with h/a<1.3. This circumstance allows one to perform "contact" voltammetric measurements of lead ions adsorbed onto a thin layer chromatography plate. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:354 / 358
页数:5
相关论文
共 32 条
[1]   Steady-state currents at sphere-cap microelectrodes and electrodes of related geometry [J].
Alfred, LCR ;
Oldham, KB .
JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (06) :2170-2177
[2]  
BAKER AL, 1999, ANAL CHIM ACTA, V385, P223
[3]   PERFORMANCE OF PLATINUM-BASED SPHERICAL MERCURY MICROELECTRODES IN CYCLIC VOLTAMMETRY AND STRIPPING ANALYSIS [J].
BALDO, MA ;
DANIELE, S ;
CORBETTA, M ;
MAZZOCCHIN, GA .
ELECTROANALYSIS, 1995, 7 (10) :980-986
[4]   RAPID ANODIC-STRIPPING ANALYSIS WITH ULTRAMICROELECTRODES [J].
BARANSKI, AS .
ANALYTICAL CHEMISTRY, 1987, 59 (04) :662-666
[5]  
Bard A.J., 1994, ELECTROANAL CHEM, V18, A., P243
[6]   THEORETICAL AND EXPERIMENTAL INVESTIGATION OF STEADY-STATE VOLTAMMETRY FOR QUASI-REVERSIBLE HETEROGENEOUS ELECTRON-TRANSFER ON A MERCURY OBLATE SPHEROIDAL MICROELECTRODE [J].
BIRKE, RL ;
HUANG, ZP .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1513-1520
[8]   GROWTH OF MERCURY ELECTRODEPOSITS ON AN INLAID DISK - VOLTAMMETRIC THEORY AND EXPERIMENTS [J].
COLYER, CL ;
LUSCOMBE, D ;
OLDHAM, KB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 283 (1-2) :379-387
[9]  
Corbetta M, 1996, ANN CHIM-ROME, V86, P77
[10]   LINEAR SWEEP AND CYCLIC VOLTAMMETRY FOR METAL-DEPOSITION AT SOLID AND MERCURY MICROELECTRODES FROM SOLUTIONS WITH AND WITHOUT SUPPORTING ELECTROLYTE [J].
DANIELE, S ;
BALDO, MA ;
CORBETTA, M ;
MAZZOCCHIN, GA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 379 (1-2) :261-270