Molecularly imprinted polymer films for reflectometric interference spectroscopic sensors

被引:58
作者
Belmont, Anne-Sophie
Jaeger, Stefanie
Knopp, Dietmar
Niessner, Reinhard
Gauglitz, Guenter
Haupt, Karsten [1 ]
机构
[1] Lund Univ, Lund, Sweden
[2] Univ Tubingen, Inst Phys & Theoret Chem, D-7400 Tubingen, Germany
[3] Tech Univ Munich, Inst Water Chem & Chem Balneol, D-8000 Munich, Germany
[4] CNRS, UMR 6022, Univ Technol Compiegne, F-60205 Compiegne, France
关键词
synthetic receptor; chemical sensor; molecularly imprinted polymer; reflectometric interference spectroscopy; thin film;
D O I
10.1016/j.bios.2007.01.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Reflectometric interference spectroscopic measurements were performed on molecularly imprinted polymer (MIP) films with the herbicide atrazine as the template molecule. A conventional imprinting protocol was used relying on non-covalent interactions between the functional monomers and the template. The MIPs were deposited on glass transducers by two different methods: spin-coating followed by in situ polymerization of thin films of monomers containing a sacrificial polymeric porogen, and autoassembly of MIP nanoparticles with the aid of an associative linear polymer. Reproducible results were obtained upon measurements of atrazine solutions in toluene with both films. Atrazine concentrations as low as 1.7 pprn could be detected with the autoassembled particle film. No or very little analyte adsorption was observed onto non-imprinted control films made by spin-coating and by particle assembly, respectively. We believe that these MIP layers in combination with the general reflectrometric transduction scheme could be a versatile sensing tool for the detection of environmentally important and other analytes. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:3267 / 3272
页数:6
相关论文
共 23 条
[1]   PROOF OF MULTILAYER STRUCTURAL ORGANIZATION IN SELF-ASSEMBLED POLYCATION POLYANION MOLECULAR FILMS [J].
DECHER, G ;
LVOV, Y ;
SCHMITT, J .
THIN SOLID FILMS, 1994, 244 (1-2) :772-777
[2]   Biomimetic properties and surface studies of a piezoelectric caffeine sensor based on electro synthesized polypyrrole [J].
Ebarvia, BS ;
Cabanilla, S ;
Sevilla, F .
TALANTA, 2005, 66 (01) :145-152
[3]   Multiple reflectance interference spectroscopy measurements made in parallel for binding studies [J].
Gauglitz, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06)
[4]   Paracetamol voltammetric microsensors based on electrocopolymerized-molecularly imprinted film modified carbon fiber microelectrodes [J].
Gómez-Caballero, A ;
Goicolea, MA ;
Barrio, RJ .
ANALYST, 2005, 130 (07) :1012-1018
[5]   Comparison of reflectometric interference spectroscopy with other instruments for label-free optical detection [J].
Hänel, C ;
Gauglitz, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) :91-100
[6]   Surface plasmon resonance sensors: review [J].
Homola, J ;
Yee, SS ;
Gauglitz, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :3-15
[7]   Surface plasmon resonance sensor using molecularly imprinted polymer for detection of sialic acid [J].
Kugimiya, A ;
Takeuchi, T .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :1059-1062
[8]   Selective separations and hydrodynamic studies: a new approach using molecularly imprinted nanosphere composite membranes [J].
Lehmam, M ;
Brunner, H ;
Tovar, GEM .
DESALINATION, 2002, 149 (1-3) :315-321
[9]   Surface plasmon resonance sensor for domoic acid based on grafted imprinted polymer [J].
Lotierzo, M ;
Henry, OYF ;
Piletsky, S ;
Tothill, I ;
Cullen, D ;
Kania, M ;
Hock, B ;
Turner, APF .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (02) :145-152
[10]   Scanning force microscopy study of the morphology of spin-cast molecular-imprinted nylon thin films [J].
Maier, P ;
Werner-Allen, J ;
Gibson, UJ ;
Richter, A ;
BelBruno, JJ .
SURFACE AND INTERFACE ANALYSIS, 2004, 36 (09) :1340-1343