Volar locking plate versus external fixation for unstable distal radius fractures: a systematic review and meta-analysis based on randomized controlled trials

被引:14
作者
Gou, Qi [1 ]
Xiong, Xiong [1 ]
Cao, Dan [2 ]
He, Yuanliang [1 ]
Li, Xu [1 ]
机构
[1] First Peoples Hosp Longquanyi Dist, Dept Orthoped, Chengdu 610100, Peoples R China
[2] First Peoples Hosp Longquanyi Dist, Dept Anesthesiol, Chengdu 610100, Peoples R China
关键词
Volar locking plates; External fixation; Putcome; Distal radius fractures; Meta-analysis; RCTs; DORSALLY DISPLACED FRACTURES; INTERNAL-FIXATION; K-WIRES; COMPLICATIONS; OUTCOMES;
D O I
10.1186/s12891-021-04312-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The outcomes for volar locking plate (VLP) and external fixation (EF) in distal radius fracture cases remain controversial. The current study of randomized controlled trials (RCTs) aimed to assess VLP and EF, which might benefit distal radius fracture cases. Methods RCTs comparing VLP and EF in distal radius fracture cases, until 18 March 2020, were systematically reviewed and summarized. The functional and radiographic outcomes, together with complications, for distal radius fracture cases, were evaluated. Results In total, 12 studies comprising 1205 distal radius fracture cases were included. The VLP group had observed lower disability in the arm shoulder and hand score (DASH) at 3rd, 6th, and 12th -month post-operation, with the mean differences (MDs) of - 10.43 (95 % CI = - 15.77 to - 5.08, P < 0.01), - 3.48 (95 % CI = - 6.37 to - 0.59, P = 0.02), and - 4.13 (95 % CI = - 6.94 to - 1.33, P < 0.01), respectively. The VLP group also had lower visual analog scale scores (VAS) compared to the EF group, with MDs of - 0.10 (95 % CI = - 0.18 to - 0.03, P < 0.01) for the former at 6th -month post-operation. Also, the EF group exhibited better grip strength than that in the VLP group, with MD of 12.48 (95 % CI = 7.00-17.95, P < 0.01) at the 3rd month and 4.54 (95 % CI = 0.31-8.76, P = 0.04) at 6th month. No significant differences in radiographic outcomes were observed between the VLP and EF groups (P > 0.05). The VLP group had a lower complication rate than that in the EF group. Conclusions VLP had a lower DASH score and VAS score but with lower grip strength. No significant differences in radiographic outcomes were observed. VLP had a lower complication rate than that of EF.
引用
收藏
页数:14
相关论文
共 38 条
[1]   Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures A randomized study of 50 patients [J].
Abramo, Antonio ;
Kopylov, Philippe ;
Geijer, Mats ;
Tagil, Magnus .
ACTA ORTHOPAEDICA, 2009, 80 (04) :478-485
[2]   OPERATING CHARACTERISTICS OF A BANK CORRELATION TEST FOR PUBLICATION BIAS [J].
BEGG, CB ;
MAZUMDAR, M .
BIOMETRICS, 1994, 50 (04) :1088-1101
[3]   Management of Severely Comminuted Distal Radius Fractures [J].
Brogan, David M. ;
Richard, Marc J. ;
Ruch, David ;
Kakar, Sanjeev .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (09) :1905-1914
[4]  
Chung KC, 2019, JAMA NETW OPEN, V2, DOI [10.1001/jamanetworkopen.2019.19433, 10.1001/jamanetworkopen.2018.7053]
[5]  
Cooper Ellis O, 2007, Am J Orthop (Belle Mead NJ), V36, pE46
[6]   A Systematic Review of Outcomes and Complications of Treating Unstable Distal Radius Fractures in the Elderly [J].
Diaz-Garcia, Rafael J. ;
Oda, Takashi ;
Shauver, Melissa J. ;
Chung, Kevin C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (05) :824-835
[7]   A revolution in the management of the distal radius? [J].
Downing, N. D. ;
Karantana, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1271-1275
[8]   Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization [J].
Duprat, Andre ;
Diaz, Juan Jose Hidalgo ;
Vernet, Paul ;
Gouzou, Stephanie ;
Facca, Sybille ;
Igeta, Yuka ;
Liverneaux, Philippe .
JOURNAL OF WRIST SURGERY, 2018, 7 (03) :237-242
[9]   Bias in meta-analysis detected by a simple, graphical test [J].
Egger, M ;
Smith, GD ;
Schneider, M ;
Minder, C .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109) :629-634
[10]   Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius -: A randomised, prospective trial [J].
Egol, K. ;
Walsh, M. ;
Tejwani, N. ;
McLaurin, T. ;
Wynn, C. ;
Paksima, N. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (09) :1214-1221