Quantitative analysis of trace elements (vanadium, sodium, and calcium) in petroleum coke using laser-induced breakdown spectroscopy with binder

被引:7
作者
Lu, Peng [1 ,2 ]
Zhuo, Zhuang [1 ]
Zhang, Wenhao [3 ]
Sun, Tengfei [4 ]
Sun, Weilin [5 ]
Lu, Jingqi [1 ]
机构
[1] Shandong Univ, Key Lab Laser & Infrared Syst, Sch Informat Sci & Engn, Minist Educ, Qingdao, Peoples R China
[2] Shandong Univ, Natl Demonstrat Ctr Expt Phys Educ, Sch Phys, Jinan 250100, Peoples R China
[3] Qilu Univ Technol, Shandong Acad Sci, Int Sch Optoelect Engn, Jinan 250300, Shandong, Peoples R China
[4] Shandong Univ Technol, Ctr Adv Laser Mfg CALM, Sch Mech Engn, Zibo 255000, Shandong, Peoples R China
[5] Shandong Zhigu Res Inst Carbon Stock Co Ltd, Lijin Cty 257442, Shandong, Peoples R China
关键词
Petroleum coke analysis; Laser-induced breakdown spectroscopy; Vanadium; sodium and calcium; Binder; PHYSICAL-CHEMICAL PROPERTIES; FEATURE-SELECTION; LIBS ANALYSIS; COAL; NICKEL; QUANTIFICATION; SULFUR; CARBON; MODEL;
D O I
10.1016/j.sab.2022.106388
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The concentrations of Vanadium (V), Sodium (Na), and Calcium (Ca) have a great effect on the quality of petroleum coke. In this work, the trace elements of V, Na, and Ca in petroleum coke were determined by laserinduced breakdown spectroscopy (LIBS). First, petroleum coke powder was mixed with the stearic acid binder and pressed into pellets to achieve a high signal repeatability. Then, to optimize the percentage of the binder in the pressed pellets, the influence of stearic acid on LIBS signal was studied in detail. When the stearic accounted for 30 w% in the mixed-pressed pellets, the plasma morphology and spectral signal were more stable. Finally, the linear calibration curves were plotted by fitting the emission line intensities and the element concentrations. In addition, the results achieved through this method were compared with other conventional methods. The determination coefficients of calibration curves of V, Na, and Ca elements all exceed 0.99. The relative standard deviations of the predicted values of V, Na, and Ca concentrations were 3.65%, 4.38%, and 5.53%, respectively. We also calculated the limit of detection of the V, Na, and Ca elements, which were 1.19 mg/kg, 0.41 mg/kg, and 0.51 mg/kg, respectively. The experimental results demonstrate that LIBS detection is an accurate and precision method for the determination of trace elements in petroleum coke.
引用
收藏
页数:9
相关论文
共 37 条
  • [1] ASTM, 2010, D50562010 ASTM
  • [2] ASTM, D63762009 ASTM
  • [3] ASTM, 2009, D56002009 ASTM
  • [4] Birghila S, 2011, ROM J PHYS, V56, P976
  • [5] BolShakov A.A., SPECTROCHIM ACTA B S, V179
  • [6] UTILIZATION OF PETROLEUM COKE AND PETROLEUM COKE/COAL BLENDS AS A MEANS OF STEAM RAISING
    BRYERS, RW
    [J]. FUEL PROCESSING TECHNOLOGY, 1995, 44 (1-3) : 121 - 141
  • [7] Cai J., SPECTROCHIM ACTA B S, V180
  • [8] LABORATORY TECHNIQUES FOR EVALUATING ASH AGGLOMERATION POTENTIAL IN PETROLEUM COKE FIRED CIRCULATING FLUIDIZED-BED COMBUSTORS
    CONN, RE
    [J]. FUEL PROCESSING TECHNOLOGY, 1995, 44 (1-3) : 95 - 103
  • [9] Characterization of coal fly ash components by laser-induced breakdown spectroscopy
    Ctvrtnickova, Tereza
    Mateo, Mari-Paz
    Yanez, Armando
    Nicolas, Gines
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (10) : 1093 - 1097
  • [10] Quantification of Mn in glass matrices using laser induced breakdown spectroscopy (LIBS) combined with chemometric approaches
    Devangad, Praveen
    Unnikrishnan, V. K.
    Tamboli, M. M.
    Shameem, K. M. Muhammed
    Nayak, Rajesh
    Choudhari, K. S.
    Santhosh, C.
    [J]. ANALYTICAL METHODS, 2016, 8 (39) : 7177 - 7184