Meta-Analysis of Usefulness of Cerebral Embolic Protection During Transcatheter Aortic Valve Implantation

被引:21
作者
Ahmad, Yousif [1 ]
Howard, James P. [2 ]
机构
[1] Cedars Sinai Med Ctr, Smidt Heart Inst, Los Angeles, CA 90048 USA
[2] Imperial Coll London, Natl Heart & Lung Inst, London, England
基金
英国惠康基金;
关键词
REPLACEMENT; DEVICE;
D O I
10.1016/j.amjcard.2021.01.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
One of the most feared complications of transcatheter aortic valve implantation (TAVI) is stroke, with increased mortality and disability observed in patients suffering a stroke after TAVI. There has been no significant decline in stroke rates seen over the last 5 years; attention has therefore been given to strategies for cerebral embolic protection. With the emergence of new randomized trial data, we sought to perform an updated systematic review and meta-analysis to examine the effect of cerebral embolic protection during TAVI both on clinical outcomes and on neuroimaging parameters. We performed a ran-dom-effects meta-analysis of randomized clinical trials of cerebral embolic protection dur -ing TAVI. The primary end point was the risk of stroke. The risk of stroke was not significantly different with the use of cerebral embolic protection: relative risk (RR) 0.88, 95% confidence interval (CI) 0.57 to 1.36, p = 0.566. Nor was there a significant reduction in the risk of disabling stroke, non-disabling stroke or death. There was no significant dif-ference in total lesion volume on MRI with cerebral embolic protection: mean difference -74.94, 95% CI-174.31 to 24.4, p = 0.139. There was also not a significant difference in the number of new ischemic lesions on MRI: mean difference -2.15, 95%-5.25 to 0.96, p = 0.176, although there was significant heterogeneity for the neuroimaging outcomes. In con-clusion, cerebral embolic protection during TAVI is safe but there is no evidence of a sta-tistically significant benefit on clinical outcomes or neuroimaging parameters. (C) 2021 The Author(s). Published by Elsevier Inc.
引用
收藏
页码:69 / 73
页数:5
相关论文
共 21 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]   A new method of applying randomised control study data to the individual patient: A novel quantitative patient-centred approach to interpreting composite end points [J].
Ahmad, Yousif ;
Nijjer, Sukhjinder ;
Cook, Christopher M. ;
El-Harasis, Majd ;
Graby, John ;
Petraco, Ricardo ;
Kotecha, Tushar ;
Baker, Christopher S. ;
Malik, Iqbal S. ;
Bellamy, Michael F. ;
Sethi, Amarjit ;
Mikhail, Ghada W. ;
Al-Bustami, Mahmud ;
Khan, Masood ;
Kaprielian, Raffi ;
Foale, Rodney A. ;
Mayet, Jamil ;
Davies, Justin E. ;
Francis, Darrel P. ;
Sen, Sayan .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 195 :216-224
[3]  
[Anonymous], 2017, J STAT SOFTWARE, P1
[4]  
[Anonymous], 2011, COCHRANE HDB SYSTEMA, P24
[5]  
Cohen DJ, 2020, TCT 2020
[6]   5-Year Outcomes of Self-Expanding Transcatheter Versus Surgical Aortic Valve Replacement in High-Risk Patients [J].
Gleason, Thomas G. ;
Reardon, Michael J. ;
Popma, Jeffrey J. ;
Deeb, Michael ;
Yakubov, Steven J. ;
Lee, Joon S. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Hermiller, James B., Jr. ;
Heiser, John ;
Merhi, William ;
Zorn, George L., III ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John V. ;
Mumtaz, Mubashir ;
Oh, Jae K. ;
Huang, Jian ;
Adams, David H. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) :2687-2696
[7]   Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis The CLEAN-TAVI Randomized Clinical Trial [J].
Haussig, Stephan ;
Mangner, Norman ;
Dwyer, Michael G. ;
Lehmkuhl, Lukas ;
Luecke, Christian ;
Woitek, Felix ;
Holzhey, David M. ;
Mohr, Friedrich W. ;
Gutberlet, Matthias ;
Zivadinov, Robert ;
Schuler, Gerhard ;
Linke, Axel .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (06) :592-601
[8]   Quantifying heterogeneity in a meta-analysis [J].
Higgins, JPT ;
Thompson, SG .
STATISTICS IN MEDICINE, 2002, 21 (11) :1539-1558
[9]   The Cochrane Collaboration's tool for assessing risk of bias in randomised trials [J].
Higgins, Julian P. T. ;
Altman, Douglas G. ;
Gotzsche, Peter C. ;
Jueni, Peter ;
Moher, David ;
Oxman, Andrew D. ;
Savovic, Jelena ;
Schulz, Kenneth F. ;
Weeks, Laura ;
Sterne, Jonathan A. C. .
BMJ-BRITISH MEDICAL JOURNAL, 2011, 343
[10]  
Hozo S. P., 2005, BMC Med Res Methodol, V5, P13, DOI [10/dt5pn6, DOI 10.1186/1471-2288-5-13]