Impact of stent malapposition on intracoronary flow dynamics: An optical coherence tomography-based patient-specific study

被引:8
作者
Wei, Lingling [1 ]
Wang, Jiaqiu [2 ]
Chen, Qiang [1 ]
Li, Zhiyong [1 ,2 ]
机构
[1] Southeast Univ, Sch Biol Sci Med Engn, Biomech Lab, Nanjing 210096, PR, Peoples R China
[2] Queensland Univ Technol, Sch Mech, Med & Proc Engn, Brisbane, Qld 4001, Australia
基金
中国国家自然科学基金;
关键词
Percutaneous coronary intervention; Stent malapposition; Computational fluid dynamics (CFD); Coronary artery; Hemodynamics; SHEAR-STRESS; FLUID-DYNAMICS; THROMBOSIS; APPOSITION; HEMODYNAMICS; BIFURCATIONS; PREDICTORS; MECHANISMS; GEOMETRY; DESIGN;
D O I
10.1016/j.medengphy.2021.06.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Percutaneous coronary intervention with stent implantation has emerged as a popular approach to treat coronary artery stenosis. Stent malapposition (SM), also referred as incomplete stent apposition, could reduce stent tissue coverage and hence increase the risk of late stent thrombosis. The objective of this study was to investigate the impact of SM on intracoronary flow dynamics by combining optical coherence tomography (OCT) image-based model reconstruction and computational analysis. Firstly, a stenosed coronary artery model was reconstructed from OCT and angiography imaging data of a patient. Two structural analyses were carried out to simulate two types of coronary artery stent implantations: a fully-apposed (FA) case and a SM case. Then, based on the two deformed coronary geometries, two computational fluid dynamics (CFD) analyses were performed to evaluate the differences of hemodynamic metrics between the FA and the SM cases, including wall shear stress (WSS), time-averaged WSS (TWSS), oscillatory shear index (OSI), WSS gradient (WSSG), time-averaged WSSG (TWSSG), and relative residence time (RRT). The results indicated that maximum flow velocity was higher in the SM case than that of the FA case, due to the incomplete expansion of the stent and artery. Moreover, the SM case had a lower percentage of areas of adverse WSS (< 0.5 Pa) and RRT (> 10/Pa) but a higher percentage of areas of adverse OSI (> 0.1) and WSSG (> 5000 Pa/m). Specifically, the differences of OSI, WSSG, and RRT between the two cases were relatively small. It was suggested that SM might not be responsible for negative hemodynamic metrics which would further result in stent thrombosis on the basis of the present specific model.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 44 条
[1]   Mechanisms, Pathophysiology, and Clinical Aspects of Incomplete Stent Apposition [J].
Attizzani, Guilherme F. ;
Capodanno, Davide ;
Ohno, Yohei ;
Tamburino, Corrado .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (14) :1355-1367
[2]   Physiological flow simulation in residual human stenoses after coronary angioplasty [J].
Banerjee, RK ;
Back, LH ;
Back, MR ;
Cho, YI .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (04) :310-320
[3]   Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations [J].
Beier, Susann ;
Ormiston, John ;
Webster, Mark ;
Cater, John ;
Norris, Stuart ;
Medrano-Gracia, Pau ;
Young, Alistair ;
Cowan, Brett .
ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (02) :315-329
[4]  
Bernad Sandor I, 2012, J Clin Med Res, V4, P177, DOI 10.4021/jocmr843w
[5]   COMPRESSIBILITY OF ARTERIAL WALL [J].
CAREW, TE ;
VAISHNAV, RN ;
PATEL, DJ .
CIRCULATION RESEARCH, 1968, 23 (01) :61-&
[6]   Haemodynamic effects of incomplete stent apposition in curved coronary arteries [J].
Chen, Winson X. ;
Poon, Eric K. W. ;
Thondapu, Vikas ;
Hutchins, Nicholas ;
Barlis, Peter ;
Ooi, Andrew .
JOURNAL OF BIOMECHANICS, 2017, 63 :164-173
[7]   Computational fluid dynamics study of common stent models inside idealised curved coronary arteries [J].
Chen, Winson X. ;
Poon, Eric K. W. ;
Hutchins, Nicholas ;
Thondapu, Vikas ;
Barlis, Peter ;
Ooi, Andrew .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (06) :671-681
[8]   Computational simulation of platelet interactions in the initiation of stent thrombosis due to stent malapposition [J].
Chesnutt, Jennifer K. W. ;
Han, Hai-Chao .
PHYSICAL BIOLOGY, 2016, 13 (01)
[9]   Computational replication of the patient-specific stenting procedure for coronary artery bifurcations: From OCT and CT imaging to structural and hemodynamics analyses [J].
Chiastra, Claudio ;
Wu, Wei ;
Dickerhoff, Benjamin ;
Aleiou, Ali ;
Dubini, Gabriele ;
Otake, Hiromasa ;
Migliavacca, Francesco ;
LaDisa, John F., Jr. .
JOURNAL OF BIOMECHANICS, 2016, 49 (11) :2102-2111
[10]   On the necessity of modelling fluid-structure interaction for stented coronary arteries [J].
Chiastra, Claudio ;
Migliavacca, Francesco ;
Martinez, Miguel Angel ;
Malve, Mauro .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 34 :217-230