Sinogram restoration of dual focal spot CT data

被引:0
作者
Forthmann, Peter [1 ]
Kohler, Thomas [1 ]
Begemann, Philipp [1 ]
Defrise, Michel [1 ]
机构
[1] Philips Res Europe Hamburg, Sector Med Imaging Syst, Rontgenstr 24-26, D-22335 Hamburg, Germany
来源
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2007年 / 6510卷
关键词
CT sinogram restoration; penalized maximum likelihood; noise; resolution;
D O I
10.1117/12.705374
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The raw data generated by a computed tomography (CT) machine are not readily usable for reconstruction. This is the result of various system non-idealities, and although the deterministic nature of corruption effects like crosstalk and afterglow permits removal through deconvolution, there is the drawback that deconvolution increases noise. Methods that perform raw data correction combined with noise suppression are commonly termed sinogram restoration methods. The need for smogram restoration arises, for example, when photon counts are low and non-statistical reconstruction algorithms like filtered backprojection are used. Many modern CT machines offer a so-called dual focal spot (DFS) mode, which serves the goal of increased radial sampling by switching the focal spot between two positions on the anode plate during the scan. Although the focal spot mode does not play a role with respect to how the data are affected by the above mentioned corruption effects, it needs to be taken into account, if regularized sinogram restoration is to be applied to the data. This work points out the subtle difference in processing that sinogram restoration for DFS requires, how it is correctly employed within the penalized maximum likelihood sinogram restoration algorithm, and what impact that has on image quality.
引用
收藏
页数:12
相关论文
共 17 条
[1]  
CARMI R, 2004, P IEEE MED IM C
[2]   Ordered subsets algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2835-2851
[3]  
Fessler J. A., 2000, Handb. Med. Imaging, V2, P1, DOI DOI 10.1117/3.831079
[4]  
FORTHMANN P, 2006, P SPIE MED IM C SAN, V6142
[5]   Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies [J].
Gies, M ;
Kalender, WA ;
Wolf, H ;
Suess, C ;
Madsen, MT .
MEDICAL PHYSICS, 1999, 26 (11) :2235-2247
[6]   Investigation of a solid-state detector for advanced computed tomography [J].
Hsieh, J ;
Gurmen, OE ;
King, KF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :930-940
[7]   Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise [J].
Hsieh, J .
MEDICAL PHYSICS, 1998, 25 (11) :2139-2147
[8]  
Hsieh J., 2003, Computed tomography: principles, design, artifacts, and recent advances
[9]  
Hutton BF, 1997, EUR J NUCL MED, V24, P797
[10]  
KACHELRIESS M, 2004, NUCL SCI S C REC IEE