Optimization of ultrasound assisted dispersive liquid-liquid microextraction of six antidepressants in human plasma using experimental design

被引:52
作者
Fernandez, P. [1 ]
Taboada, V. [1 ]
Regenjo, M. [1 ]
Morales, L. [1 ]
Alvarez, I. [1 ]
Carro, A. M. [2 ]
Lorenzo, R. A. [2 ]
机构
[1] Univ Santiago de Compostela, Fac Med, Dpto Anat Patol & Ciencias Forenses, Santiago De Compostela 15782, Spain
[2] Univ Santiago de Compostela, Fac Quim, Dpto Quim Analit Nutr & Bromatol, Santiago De Compostela 15782, Spain
关键词
Dispersive-liquid-liquid microextraction; Second-generation antidepressants; Human plasma; Experimental design; CHROMATOGRAPHY-MASS SPECTROMETRY; HUMAN URINE; DRUGS; FLUOXETINE; SAMPLES; BENZODIAZEPINES; CITALOPRAM; ABUSE; WATER;
D O I
10.1016/j.jpba.2016.02.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple Ultrasounds Assisted-Dispersive Liquid Liquid Microextraction (UA-DLLME) method is presented for the simultaneous determination of six second-generation antidepressants in plasma by Ultra Performance Liquid Chromatography with Photodiode Array Detector (UPLC-PDA). The main factors that potentially affect to DLLME were optimized by a screening design followed by a response surface design and desirability functions. The optimal conditions were 2.5 mL of acetonitrile as dispersant solvent, 0.2 mL of chloroform as extractant solvent, 3 min of ultrasounds stirring and extraction pH 9.8. Under optimized conditions, the UPLC-PDA method showed good separation of antidepressants in 2.5 min and good linearity in the range of 0.02-4 mu g mL(-1), with determination coefficients higher than 0.998. The limits of detection were in the range 4-5 ng mL(-1). The method precision (n = 5) was evaluated showing relative standard deviations (RSD) lower than 8.1% for all compounds. The average recoveries ranged from 92.5% for fluoxetine to 110% for mirtazapine. The applicability of DLLME/UPLC-PDA was successfully tested in twenty nine plasma samples from antidepressant consumers. Real samples were analyzed by the proposed method and the results were successfully submitted to comparison with those obtained by a Liquid Liquid Extraction-Gas Chromatography - Mass Spectrometry (LLE-GC-MS) method. The results confirmed the presence of venlafaxine in most cases (19 cases), followed by sertraline (3 cases) and fluoxetine (3 cases) at concentrations below toxic levels. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 197
页数:9
相关论文
共 28 条
[1]  
Agenda Espanola de Medicamentos y Productos Sanitarios (Web), 2015, UADV114012015 AG ESP
[2]  
Akbar A., 2015, BIOMED CHROMATOGR, V29, P1094
[3]  
[Anonymous], 2001, Guidance for industry: bioanalytical method validation
[4]   Polypyrrole/magnetic nanoparticles composite as an efficient sorbent for dispersive micro-solid-phase extraction of antidepressant drugs from biological fluids [J].
Asgharinezhad, Ali Akbar ;
Karami, Sara ;
Ebrahimzadeh, Homeira ;
Shekari, Nafiseh ;
Jalilian, Niloofar .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 494 (01) :102-112
[5]   Prescribing patterns of antidepressants in europe: Results from the Factors Influencing Depression Endpoints Research (FINDER) study [J].
Bauer, Michael ;
Monz, Brigitta U. ;
Montejo, Angel L. ;
Quail, Deborah ;
Dantchev, Nicolas ;
Dernyttenaere, Koen ;
Garcia-Cebrian, Ana ;
Grassi, Luigi ;
Perahia, David G. S. ;
Reed, Catherine ;
Tylee, Andre .
EUROPEAN PSYCHIATRY, 2008, 23 (01) :66-73
[6]   Tandem dispersive liquid-liquid microextraction as an efficient method for determination of basic drugs in complicated matrices [J].
Bazregar, Mohammad ;
Rajabi, Maryam ;
Yamini, Yadollah ;
Saffarzadeh, Zahra ;
Asghari, Alireza .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1429 :13-21
[7]   Solid-phase microextraction using poly(pyrrole) film and liquid chromatography with UV detection for analysis of antidepressants in plasma samples [J].
Chaves, Andrea Rodrigues ;
Chiericato Junior, Glaico ;
Costa Queiroz, Maria Eugema .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (07) :587-593
[8]   Analysis of drugs of abuse in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography [J].
Fernandez, P. ;
Regenjo, M. ;
Bermejo, A. M. ;
Fernandez, A. M. ;
Lorenzo, R. A. ;
Carro, A. M. .
JOURNAL OF APPLIED TOXICOLOGY, 2015, 35 (04) :418-425
[9]  
Fernández P, 2014, ANAL METHODS-UK, V6, P8239, DOI [10.1039/c4ay01348d, 10.1039/C4AY01348D]
[10]   A rapid ultrasound-assisted dispersive liquid-liquid microextraction followed by ultra-performance liquid chromatography for the simultaneous determination of seven benzodiazepines in human plasma samples [J].
Fernandez, Purificacion ;
Gonzalez, Cristina ;
Teresa Pena, M. ;
Carro, Antonia M. ;
Lorenzo, Rosa A. .
ANALYTICA CHIMICA ACTA, 2013, 767 :88-96