Assessment of airborne environmental bacteria and related factors in 25 underground railway stations in Seoul, Korea

被引:50
作者
Hwang, Sung Ho [2 ]
Yoon, Chung Sik [2 ]
Ryu, Kyong Nam [2 ]
Paik, Samuel Y. [3 ]
Cho, Jun Ho [1 ]
机构
[1] Hanyang Womens Coll, Seoul 133793, South Korea
[2] Seoul Natl Univ, Sch Publ Hlth, Inst Hlth & Environm Sci, Seoul 110799, South Korea
[3] Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
关键词
Total airborne bacteria; Underground railway stations; Platform screen door; Depth; Temperature; Environmental bacteria; EXPOSURE; INDOOR; FUNGI; BIOAEROSOLS; BUILDINGS; SYMPTOMS;
D O I
10.1016/j.atmosenv.2010.01.047
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study assessed bacterial concentrations in indoor air at 25 underground railway stations in Seoul, Korea, and investigated various related factors including the presence of platform screen doors (PSD), depth of the station, year of construction, temperature, relative humidity, and number of passengers. A total of 72 aerosol samples were collected from all the stations. Concentrations of total airborne bacteria (TAB) ranged from not detected (ND) to 4997 CFU m(-3), with an overall geometric mean (GM) of 191 CFU m(-3). Airborne bacteria were detected at 23 stations (92%) and Gram-negative bacteria (GNB) were detected at two stations (8%). TAB concentrations of four stations (16%) exceeded 800 CFU m(-3), the Korea indoor bio-aerosol guideline. The results of the study showed that TAB concentrations at the stations without PSD showed higher TAB concentrations than those with PSD, though not at statistically significant levels. TAB concentrations of deeper stations revealed significantly higher levels than those of shallower stations. Based on this study, it is recommended that mitigation measures be applied to improve the indoor air quality (IAQ) of underground railway stations in Seoul, with focused attention on deeper stations. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1658 / 1662
页数:5
相关论文
共 28 条
[1]   Environmental study in subway metro stations in Cairo, Egypt [J].
Awad, AHA .
JOURNAL OF OCCUPATIONAL HEALTH, 2002, 44 (02) :112-118
[2]   Airborne fungi in four stations of the St. Petersburg Underground railway system [J].
Bogomolova, Evgenia ;
Kirtsideli, Irina .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2009, 63 (02) :156-160
[3]   Temporal variation of airborne fungi concentrations and related factors in subway stations in Seoul, Korea [J].
Cho, Jun Ho ;
Min, Kyung Hee ;
Paik, Nam Won .
INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2006, 209 (03) :249-255
[4]  
Dillon HK, 1996, FIELD GUIDE DETERMIN, P119
[5]   Bioaerosol health effects and exposure assessment: Progress and prospects [J].
Douwes, J ;
Thorne, P ;
Pearce, N ;
Heederik, D .
ANNALS OF OCCUPATIONAL HYGIENE, 2003, 47 (03) :187-200
[6]   Quantitative relationship of sick building syndrome symptoms with ventilation rates [J].
Fisk, W. J. ;
Mirer, A. G. ;
Mendell, M. J. .
INDOOR AIR, 2009, 19 (02) :159-165
[7]   A preliminary survey of aerial biocontaminants at six London Underground stations [J].
Gilleberg, SB ;
Faull, JL ;
Graeme-Cook, KA .
INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 1998, 41 (02) :149-152
[8]  
*INCH RAP TRANS CO, 2008, INFORM MAT 0806
[9]  
Jensen PA., 1998, NIOSH manual of analytical methods, V1, P82, DOI [DOI 10.26616/nioshpub82100, DOI 10.26616/NIOSHPUB82100]
[10]   Workplace exposure to bioaerosols in pet shops, pet clinics, and flower gardens [J].
Jo, Wan-Kuen ;
Kang, Jung-Hwan .
CHEMOSPHERE, 2006, 65 (10) :1755-1761