Diagnostic Ability of Retinal Nerve Fiber Layer Imaging by Swept-Source Optical Coherence Tomography in Glaucoma

被引:51
作者
Yang, Zhiyong [1 ,2 ]
Tatham, Andrew J. [1 ,2 ]
Zangwill, Linda M. [1 ,2 ]
Weinreb, Robert N. [1 ,2 ]
Zhang, Chunwei [1 ,2 ,3 ]
Medeiros, Felipe A. [1 ,2 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, La Jolla, CA 92093 USA
[3] Harbin Med Univ, Affiliated Hosp 1, Dept Ophthalmol, Harbin, Peoples R China
关键词
OPERATING CHARACTERISTIC CURVES; OCULAR HYPERTENSION; CHOROIDAL THICKNESS; PROGRESSION; TESTS; DAMAGE; AREAS; DISC;
D O I
10.1016/j.ajo.2014.10.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the diagnostic accuracies of swept-source optical coherence tomography (OCT) wide-angle and peripapillary retinal nerve fiber layer (RNFL) thickness measurements for glaucoma detection. DESIGN: Cross-sectional case-control study. METHODS: In this study we enrolled 144 glaucomatous eyes of 106 subjects and 66 eyes of 42 healthy subjects from the Diagnostic Innovations in Glaucoma Study. Glaucoma was defined by the presence of repeatable abnormal standard automated perimetry results and/or progressive glaucomatous optic disc change on masked grading of stereophotographs. Wide-angle and peripapillary RNFL thicknesses were assessed using sweptsource OCT. Peripapillary RNFL thickness was also evaluated using spectral-domain OCT. Areas under the receiver operating characteristic (ROC) curves were calculated to evaluate the ability of the different sweptsource OCT and spectral-domain OCT parameters to discriminate between glaucomatous and healthy eyes. RESULTS: Mean (standard deviation) average spectral-domain OCT wide-angle RNFL thicknesses were 50.5 5.8 mu m and 35.0 9.6 mu m in healthy and glaucomatous eyes, respectively (P < 0.001). Corresponding values for swept-source OCT peripapillary RNFL thicknesses were 103.5 12.3 pm and 72.9 16.5 pm, respectively (P < 0.001). Areas under the ROC curves of swept-source OCT wide-angle and peripapillary RNFL thickness were 0.88 and 0.89, respectively. Swept-source OCT performed similar to average peripapillary RNFL thickness obtained by spectral-domain OCT (area under the ROC curve of 0.90). CONCLUSION: Swept-source OCT wide-angle and penpapillary RNFL thickness measurements performed well for detecting glaucomatous damage. The diagnostic accuracies of the swept-source OCT and spectral-domain OCT RNFL imaging protocols evaluated in this study were similar. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:193 / 201
页数:9
相关论文
共 29 条
[1]   Comparative Assessment for the Ability of Cirrus, RTVue, and 3D-OCT to Diagnose Glaucoma [J].
Akashi, Azusa ;
Kanamori, Akiyasu ;
Nakamura, Makoto ;
Fujihara, Masashi ;
Yamada, Yuko ;
Negi, Akira .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) :4478-4484
[2]   Staging functional damage in glaucoma: Review of different classification methods [J].
Brusini, Paolo ;
Johnson, Chris A. .
SURVEY OF OPHTHALMOLOGY, 2007, 52 (02) :156-179
[3]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[4]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[5]   Partial AUC estimation and regression [J].
Dodd, LE ;
Pepe, MS .
BIOMETRICS, 2003, 59 (03) :614-623
[6]   Diagnosis of glaucoma and detection of glaucoma progression using spectral domain optical coherence tomography [J].
Grewal, Dilraj S. ;
Tanna, Angelo P. .
CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (02) :150-161
[7]   Neural losses correlated with visual losses in clinical perimetry [J].
Harwerth, RS ;
Carter-Dawson, L ;
Smith, EL ;
Barnes, G ;
Holt, WF ;
Crawford, MLJ .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) :3152-3160
[8]   Glaucomatous damage of the macula [J].
Hood, Donald C. ;
Raza, Ali S. ;
de Moraes, Carlos Gustavo V. ;
Liebmann, Jeffrey M. ;
Ritch, Robert .
PROGRESS IN RETINAL AND EYE RESEARCH, 2013, 32 :1-21
[9]  
Kass MA, 2002, ARCH OPHTHALMOL-CHIC, V120, P701
[10]   Comparison of the Diagnostic Accuracies of the Spectralis, Cirrus, and RTVue Optical Coherence Tomography Devices in Glaucoma [J].
Leite, Mauro T. ;
Rao, Harsha L. ;
Zangwill, Linda M. ;
Weinreb, Robert N. ;
Medeiros, Felipe A. .
OPHTHALMOLOGY, 2011, 118 (07) :1334-1339