First clinical experiences with an endovascular clamping system for neuroprotection during carotid stenting

被引:27
作者
Diederich, KW
Scheinert, D
Schmidt, A
Scheinert, S
Reimers, B
Sievert, H
Rabe, K
Coppi, G
Moratto, R
Hoffmann, FJ
Schuler, GC
Biamino, G
机构
[1] Univ Leipzig, Ctr Heart, Clin Internal Med Cardiol, D-04289 Leipzig, Germany
[2] Hosp Mirano, Dept Cardiol, Mirano, Italy
[3] Ctr Cardiol & Vasc Intervent, Frankfurt, Germany
[4] Hosp Modena, Dept Vasc Surg, Modena, Italy
[5] Hosp Neunkirchen, Neunkirchen, Germany
关键词
carotid arteries; carotid artery stenting; cerebral protection device; endovascular clamping;
D O I
10.1016/j.ejvs.2004.08.012
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives. This report evaluates the feasibility and efficacy of an endovascular blood flow blockage technique to prevent intracerebral embolization of plaque debris during carotid artery stenting. Methods. Forty-two patients were enrolled in five clinical sites in Germany and Italy with either an asymptomatic internal carotid artery stenosis greater than or equal to75% (mean 87%) or a symptomatic stenosis >60% (mean 85%). Cerebral protection during the stenting procedure was achieved using an endovascular clamping technique, obtained by occlusion of the external and common carotid artery via two independently inflatable balloons integrated in the Mo.Ma((R)) system. Blood with particulate plaque debris was aspirated before flow was restored. The patient's clinical and the neurological status were assessed during intervention, at discharge, and at 3 months follow-up. Results. Stenting was performed in all but one patient. The mean flow occlusion time was 10.6 +/- 6.5 min. Transient clamping intolerance was observed in five patients (12%). In two patients, neurological deficits persisted for 2 and 12 h, respectively. Two minor strokes (4,7%) occurred at 5 and 72 h after the procedure. No major strokes or deaths were observed at 3 months follow-up. Conclusions. This first clinical experience with the Mo.Ma((R)) device substantiates the feasibility of endovascular clamping in preventing cerebral embolization during carotid artery stenting.
引用
收藏
页码:629 / 633
页数:5
相关论文
共 14 条
[1]  
Adami CA, 2002, J ENDOVASC THER, V9, P147, DOI 10.1583/1545-1550(2002)009<0147:UOTPAE>2.0.CO
[2]  
2
[3]   Multicenter evaluation of carotid artery stenting with a filter protection system [J].
Al-Mubarak, N ;
Colombo, A ;
Gaines, PA ;
Iyer, SS ;
Corvaja, N ;
Cleveland, TJ ;
Macdonald, S ;
Brennan, C ;
Vitek, JJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) :841-846
[4]  
Castriota F, 2002, J ENDOVASC THER, V9, P786, DOI 10.1583/1545-1550(2002)009<0786:IOCPDO>2.0.CO
[5]  
2
[6]   Protected carotid stenting - Clinical advantages and complications of embolic protection devices in 442 consecutive patients [J].
Cremonesi, A ;
Manetti, R ;
Setacci, F ;
Setacci, C ;
Castriota, F .
STROKE, 2003, 34 (08) :1936-1941
[7]  
Henry M, 1999, J ENDOVASC SURG, V6, P321, DOI 10.1583/1074-6218(1999)006<0321:CSWCPF>2.0.CO
[8]  
2
[9]  
Macdonald S, 2002, J ENDOVASC THER, V9, P777, DOI 10.1583/1545-1550(2002)009<0777:NOACSP>2.0.CO
[10]  
2