Thermal and fast neutron detection through high-purity single-crystal CVD diamonds

被引:6
作者
Lee, Chul-Yong [1 ]
Ban, Chae-Min [1 ]
Lee, Han-Rim [1 ]
Choo, Kee-Nam [1 ]
Jun, Byung-Hyuk [1 ]
机构
[1] KAERI, 111 Daedeok Daero,989 Beon Gil, Daejeon, South Korea
基金
新加坡国家研究基金会;
关键词
Diamond neutron detector; Fast neutron; Thermal neutron; Gd converting layer; RADIATION DETECTORS; NUCLEAR;
D O I
10.1016/j.apradiso.2019.06.025
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
We developed neutron detectors for detecting thermal and fast neutrons. The sensing element of the neutron detector uses a high-purity chemical-vapor-deposited (CVD) diamond plate, with a size of 3 mm x 3 mm x 0.5 mm, and the empty set5 mm detector is sealed for use in the reactor as a small tube by using laser micro welding. The electrodes of the fast and thermal neutron detectors are made up of Ag and Gd with approximately 100-nm and 5 mu m thicknesses, respectively. The deposition method of the electrode uses the RF plasma sputtering system. The developed neutron detectors were tested on a 30-MeV cyclotron, which generates fast neutrons and gamma rays. High-density polyethylene plates, Cd plates, and Pb bricks were used for the moderator and shielding. The Ag electrode detector measured the current generated by fast neutrons and gamma rays. Although the sensitivity of the Gd electrode detector is smaller than that of the Ag electrode detector, it measured the current generated by thermal neutrons as well as fast neutrons and gamma rays.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 23 条
[1]   Thermal neutron dosimeter by synthetic single crystal diamond devices [J].
Almaviva, S. ;
Marinelli, Marco ;
Milani, E. ;
Prestopino, G. ;
Tucciarone, A. ;
Verona, C. ;
Verona-Rinati, G. ;
Angelone, M. ;
Pillon, M. .
APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) :S183-S185
[2]   Thermal and fast neutron detection in chemical vapor deposition single-crystal diamond detectors [J].
Almaviva, S. ;
Marinelli, M. ;
Milani, E. ;
Prestopino, G. ;
Tucciarone, A. ;
Verona, C. ;
Verona-Rinati, G. ;
Angelone, M. ;
Lattanzi, D. ;
Pillon, M. ;
Montereali, R. M. ;
Vincenti, M. A. .
JOURNAL OF APPLIED PHYSICS, 2008, 103 (05)
[3]  
Brambilla, 2011, NUCL INSTRUM METH A, V458, P220
[4]   CVD diamonds in the BaBar radiation monitoring system [J].
Bruinsma, M ;
Burchat, B ;
Edwards, AJ ;
Kagan, H ;
Kass, R ;
Kirkby, D ;
Petersen, BA .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2006, 150 :164-167
[5]   Diamond dosimetry: Outcomes of the CANDIDO and CONRAD INFN projects [J].
Bucciolini, M ;
Borchi, E ;
Bruzzi, M ;
Casati, M ;
Cirrone, P ;
Cuttone, G ;
De Angelis, C ;
Lovik, I ;
Onori, S ;
Raffaele, L ;
Sciortino, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 552 (1-2) :189-196
[6]  
CiVidec material, 2017, B6 HT HIGH TEMP THER
[7]   Characterisation of CVD diamond detectors used for fast neutron flux monitoring [J].
Foulon, F ;
Bergonzo, P ;
Amosov, VN ;
Kaschuck, Y ;
Frunze, V ;
Tromson, D ;
Brambilla, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2) :495-499
[8]   Performance of Monocrystalline Diamond Radiation Detectors Fabricated Using TiW, Cr/Au and a Novel Ohmic DLC/Pt/Au Electrical Contact [J].
Galbiati, A. ;
Lynn, S. ;
Oliver, K. ;
Schirru, F. ;
Nowak, T. ;
Marczewska, B. ;
Duenas, J. A. ;
Berjillos, R. ;
Martel, I. ;
Lavergne, L. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (04) :1863-1874
[9]  
Ho, 2013, J RADIOL PROTECT, V38, P143
[10]   Response function measurement of layered type CVD single crystal diamond radiation detectors for 14 MeV neutrons [J].
Kaneko, JH ;
Teraji, T ;
Hirai, Y ;
Shiraishi, M ;
Kawamura, S ;
Yoshizaki, S ;
Ito, T ;
Ochiai, K ;
Nishitani, T ;
Sawamura, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :3581-3584