Experimental Realisation of High-sensitivity Laboratory X-ray Grating-based Phase-contrast Computed Tomography

被引:61
作者
Birnbacher, Lorenz [1 ,2 ]
Willner, Marian [1 ,2 ]
Velroyen, Astrid [1 ,2 ]
Marschner, Mathias [1 ,2 ]
Hipp, Alexander [3 ]
Meiser, Jan [4 ]
Koch, Frieder [4 ]
Schroeter, Tobias [4 ]
Kunka, Danays [4 ]
Mohr, Juergen [4 ]
Pfeiffer, Franz [1 ,2 ]
Herzen, Julia [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, Lehrstuhl Biomed Phys, Garching, Germany
[2] Tech Univ Munich, Inst Med Tech, Garching, Germany
[3] Helmholtz Zentrum Geesthacht, Zentrum Mat & Kustenforsch, D-21502 Geesthacht, Germany
[4] Karlsruher Inst Technol, Inst Mikrostrukt Tech, Karlsruhe, Germany
基金
欧洲研究理事会;
关键词
SPATIAL-RESOLUTION; QUANTITATIVE PHASE; HUMAN CEREBELLUM; RECONSTRUCTION; ABSORPTION;
D O I
10.1038/srep24022
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The possibility to perform high-sensitivity X-ray phase-contrast imaging with laboratory grating-based phase-contrast computed tomography (gbPC-CT) setups is of great interest for a broad range of high-resolution biomedical applications. However, achieving high sensitivity with laboratory gbPC-CT setups still poses a challenge because several factors such as the reduced flux, the polychromaticity of the spectrum, and the limited coherence of the X-ray source reduce the performance of laboratory gbPC-CT in comparison to gbPC-CT at synchrotron facilities. In this work, we present our laboratory X-ray Talbot-Lau interferometry setup operating at 40 kVp and describe how we achieve the high sensitivity yet unrivalled by any other laboratory X-ray phase-contrast technique. We provide the angular sensitivity expressed via the minimum resolvable refraction angle both in theory and experiment, and compare our data with other differential phase-contrast setups. Furthermore, we show that the good stability of our high-sensitivity setup allows for tomographic scans, by which even the electron density can be retrieved quantitatively as has been demonstrated in several preclinical studies.
引用
收藏
页数:8
相关论文
共 43 条
[1]   X-ray imaging with the PILATUS 100k detector [J].
Bech, M. ;
Bunk, O. ;
David, C. ;
Kraft, P. ;
Broennimann, C. ;
Eikenberry, E. F. ;
Pfeiffer, F. .
APPLIED RADIATION AND ISOTOPES, 2008, 66 (04) :474-478
[2]   X-ray phase-contrast imaging: from pre-clinical applications towards clinics [J].
Bravin, Alberto ;
Coan, Paola ;
Suortti, Pekka .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) :R1-R35
[3]   Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography [J].
Chen, Guang-Hong ;
Zambelli, Joseph ;
Li, Ke ;
Bevins, Nicholas ;
Qi, Zhihua .
MEDICAL PHYSICS, 2011, 38 (02) :584-588
[4]   Edge illumination X-ray phase-contrast imaging: nanoradian sensitivity at synchrotrons and translation to conventional sources [J].
Diemoz, P. C. ;
Endrizzi, M. ;
Hagen, C. K. ;
Rau, C. ;
Bravin, A. ;
Speller, R. D. ;
Robinson, I. K. ;
Olivo, A. .
22ND INTERNATIONAL CONGRESS ON X-RAY OPTICS AND MICROANALYSIS, 2014, 499
[5]   Inverse geometry for grating-based x-ray phase-contrast imaging [J].
Donath, Tilman ;
Chabior, Michael ;
Pfeiffer, Franz ;
Bunk, Oliver ;
Reznikova, Elena ;
Mohr, Juergen ;
Hempel, Eckhard ;
Popescu, Stefan ;
Hoheisel, Martin ;
Schuster, Manfred ;
Baumann, Joachim ;
David, Christian .
JOURNAL OF APPLIED PHYSICS, 2009, 106 (05)
[6]   The fractional Talbot effect in differential x-ray phase-contrast imaging for extended and polychromatic x-ray sources [J].
Engelhardt, M. ;
Kottler, C. ;
Bunk, O. ;
David, C. ;
Schroer, C. ;
Baumann, J. ;
Schuster, M. ;
Pfeiffer, F. .
JOURNAL OF MICROSCOPY, 2008, 232 (01) :145-157
[7]   High-resolution differential phase contrast imaging using a magnifying projection geometry with a microfocus x-ray source [J].
Engelhardt, Martin ;
Baumann, Joachim ;
Schuster, Manfred ;
Kottler, Christian ;
Pfeiffer, Franz ;
Bunk, Oliver ;
David, Christian .
APPLIED PHYSICS LETTERS, 2007, 90 (22)
[8]   Simulated Cystic Renal Lesions: Quantitative X-ray Phase-Contrast CT-An in Vitro Phantom Study [J].
Fingerle, Alexander A. ;
Willner, Marian ;
Herzen, Julia ;
Muenzel, Daniela ;
Hahn, Dieter ;
Rummeny, Ernst J. ;
Noel, Peter B. ;
Pfeiffer, Franz .
RADIOLOGY, 2014, 272 (03) :739-748
[9]   Phase-sensitive x-ray imaging [J].
Fitzgerald, R .
PHYSICS TODAY, 2000, 53 (07) :23-26
[10]   Visualizing Typical Features of Breast Fibroadenomas Using Phase-Contrast CT: An Ex-Vivo Study [J].
Grandl, Susanne ;
Willner, Marian ;
Herzen, Julia ;
Sztrokay-Gaul, Aniko ;
Mayr, Doris ;
Auweter, Sigrid D. ;
Hipp, Alexander ;
Birnbacher, Lorenz ;
Marschner, Mathias ;
Chabior, Michael ;
Reiser, Maximilian ;
Pfeiffer, Franz ;
Bamberg, Fabian ;
Hellerhoff, Karin .
PLOS ONE, 2014, 9 (05)