A Generalized Delayed Signal Cancellation Method for Detecting Fundamental-Frequency Positive-Sequence Three-Phase Signals

被引:139
作者
Neves, Francisco A. S. [1 ]
Cavalcanti, Marcelo Cabral [1 ]
Paz de Souza, Helber Elias [2 ]
Bradaschia, Fabricio [1 ]
Bueno, Emilio J. [3 ]
Rizo, Mario [3 ]
机构
[1] Univ Fed Pernambuco, Dept Elect Engn & Power Syst, BR-50740530 Recife, PE, Brazil
[2] Fed Inst Educ, Dept Ind, BR-55200000 Pesqueira, Brazil
[3] Univ Alcala de Henares, Dept Elect, Madrid 28870, Spain
关键词
Converters; power quality (PQ); voltage control; POWER; HARMONICS; SYSTEM; SYNCHRONIZATION; INTEGRATORS; CONVERTERS;
D O I
10.1109/TPWRD.2010.2044196
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel scheme for obtaining the fundamental-frequency positive-sequence grid voltage vector based on a generalization of the delayed signal cancellation method is proposed in this paper. The technique is implemented by sampling and storing the instantaneous voltage vector. A mathematical transformation is then proposed through which the current and delayed voltage vectors are combined. It is shown that the proposed transformation has unity gain for the fundamental-frequency positive-sequence voltage vector, while its gain is equal to zero for some chosen components. Cascaded transformations can then be used for eliminating the fundamental-frequency negative-sequence vector, as well as chosen positive-and negative-sequence harmonic vector components and, thus, for accurately obtaining the fundamental-frequency positive-sequence voltage vector. The output of the last transformation block is input to a synchronous reference frame phase-locked loop for detecting frequency and position of the positive-sequence vector. A proposal for making the scheme frequency adaptive is also presented. The good performance of the proposed method is verified with simulations and experiments by using distorted and unbalanced signals, containing fundamental-frequency as well as positive-and negative-sequence harmonic components. The proposed method frequency adaptation capability is also verified.
引用
收藏
页码:1816 / 1825
页数:10
相关论文
共 30 条
[1]  
[Anonymous], P 31 ANN C IEEE IND
[2]  
[Anonymous], ADV POWER CONVERTERS
[3]  
[Anonymous], 61000434 IEC
[4]  
Arruda LN, 2001, IEEE IND APPLIC SOC, P2655, DOI 10.1109/IAS.2001.955993
[5]   Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame [J].
Bojoi, RI ;
Griva, G ;
Bostan, V ;
Guerriero, M ;
Farina, F ;
Profumo, F .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) :1402-1412
[6]   Effect of sampling frequency and harmonics on delay-based phase-sequence estimation method [J].
Bongiorno, Massimo ;
Svensson, Jan ;
Sannino, Ambra .
IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) :1664-1672
[7]   A phase tracking system for three phase utility interface inverters [J].
Chung, SK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :431-438
[8]  
CUTRI R, 2007, P BRAZ POW EL C COBE, P1
[9]   A Method for Extracting the Fundamental-Frequency Positive-Sequence Voltage Vector Based on Simple Mathematical Transformations [J].
de Souza, Helber E. P. ;
Bradaschia, Fabricio ;
Neves, Francisco A. S. ;
Cavalcanti, Marcelo C. ;
Azevedo, Gustavo M. S. ;
de Arruda, Josue P. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (05) :1539-1547
[10]   A novel three-phase magnitude-phase-locked loop system [J].
Karimi-Ghartemani, M. .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2006, 53 (08) :1792-1802