Accuracy of renal volume assessment in children by three-dimensional sonography

被引:19
作者
Fritz, GA
Riccabona, M
Bohdal, G
Quehenberger, F
机构
[1] Univ Klinikum Graz, Radiol Klin, Graz, Austria
[2] Univ Klinikum Graz, Inst Med Informat Stat & Dokumentat, Graz, Austria
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2003年 / 175卷 / 04期
关键词
tree-dimensional ultrasound; pediatric; volume; kidney; children;
D O I
10.1055/s-2003-38442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 +/- 4.6% versus a mean difference of -2.4 +/- 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 +/- 4.4% for 3DUS and -3.8 +/- 14.7 % for 2DUS. In hydronephrosis, the accuracy was +4.0 +/- 5.9% and +9.6 +/- 21.3 %, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were +/-7.3% and +/- 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI.
引用
收藏
页码:540 / 546
页数:7
相关论文
共 30 条
  • [11] Usability of semiautomatic segmentation algorithms for tumor volume determination
    Mahr, A
    Levegrün, S
    Bahner, ML
    Kress, J
    Zuna, I
    Schlegel, W
    [J]. INVESTIGATIVE RADIOLOGY, 1999, 34 (02) : 143 - 150
  • [12] Three-dimensional echocardiography in congenital heart disease: A continuum of unfulfilled promises? No. A presently clinically applicable technology with an important future? Yes
    Marx, GR
    Sherwood, MC
    [J]. PEDIATRIC CARDIOLOGY, 2002, 23 (03) : 266 - 285
  • [13] Matre K, 1999, Eur J Ultrasound, V10, P65, DOI 10.1016/S0929-8266(99)00044-0
  • [14] Three-dimensional transvaginal neurosonography of the fetal brain: 'navigating' in the volume scan
    Monteagudo, A
    Timor-Tritsch, IE
    Mayberry, P
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (04) : 307 - 313
  • [15] Accuracy of volume measurement using helical CT
    Nawaratne, S
    Fabiny, R
    Brien, JE
    Zalcberg, J
    Cosolo, W
    Whan, A
    Morgan, DJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) : 481 - 486
  • [16] COMPENSATORY HYPERTROPHY EFFECTIVELY ASSESSES THE DEGREE OF IMPAIRED RENAL-FUNCTION IN UNILATERAL RENAL-DISEASE
    OSULLIVAN, DC
    DEWAN, PA
    GUINEY, EJ
    [J]. BRITISH JOURNAL OF UROLOGY, 1992, 69 (04): : 346 - 350
  • [17] RICCABONA M, 1995, J ULTRAS MED, V14, P881
  • [18] Riccabona M, 1996, J ULTRAS MED, V15, P627
  • [19] Feasibility of MR urography in neonates and infants with anomalies of the upper urinary tract
    Riccabona, M
    Simbrunner, J
    Ring, E
    Ruppert-Kohlmayr, A
    Ebner, F
    Fotter, R
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (06) : 1442 - 1450
  • [20] ULTRASOUND SCREENING FOR FETAL URINARY-TRACT MALFORMATIONS - A PROSPECTIVE-STUDY IN GENERAL-POPULATION
    ROSENDAHL, H
    [J]. EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1990, 36 (1-2): : 27 - 33