Concordance between 3 methods of measurement the ankle-brachial index to diagnose peripheral artery disease

被引:6
作者
Fores, Rosa [1 ,2 ]
Alzamora, Maria Teresa [1 ,2 ]
Pera, Guillem [2 ]
Toran, Pere [2 ]
Urrea, Magali [2 ]
Heras, Antonio [1 ,2 ]
机构
[1] Inst Catala Salut, Ctr Atencio Primaria Riu Nord Riu Sud, Barcelona, Spain
[2] Inst Univ Invest Atencio Primaria Jordi Gol IDIAP, Unitat Suport Recerca Metropolitana Nord, Barcelona, Spain
来源
MEDICINA CLINICA | 2014年 / 143卷 / 08期
关键词
Peripheral arterial disease; Ankle-brachial index; Automatic devices; Arterial calcification; Sensitivity; Specificity; OSCILLOMETRIC DEVICE; OCCLUSIVE DISEASE; PRESSURE INDEX; BLOOD-PRESSURE; DOPPLER; VALIDATION; MORTALITY; METAANALYSIS; PREVALENCE;
D O I
10.1016/j.medcli.2013.10.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: To determine the concordance of the ankle-brachial index (ABI) determiried by automatic measurements (sphygmomanometer Omron and the triple cuff device) using doppler as the gold-standard, computing as well as sensitivity and specificity. Patients and methods: ARTPER population cohort subjects, classified as peripheral arterial disease (PAD) if ABI < 0.9, calcified if ABI >= 1.4 and healthy otherwise. To asses concordance we used kappa index using the 3 categories and the intraclass correlation coefficient (ICC) for ABI continuous values. Results: Eighty-eight participants, 52% women, 57-87 years. It was possible to calculate the ABI using doppler for 100%, 97% using Omron and 95% using triple. ABI means (standard deviation) were: doppler 1.089 (0.236), Omron 1.082 (0.110), triple 1.146 (0.134), with poor agreement (ICC doppler/Omron = 0.27, doppler/ triple = 0.13, and triple/Omron = 0.39). Categorizing ABI as PAD-healthy-calcified 13.6% (doppler), 6.8% (Omron) and 3.4% (triple) were PAD and 9.1% (doppler), 1.1% (Omron) and 9.1% (triple) were calcified. Kappa indexes were weak (doppler/Omron = 0.22, doppler/triple = 0.01, triple/Omron = 0.17). Both triple and Omron were highly specific (97%) but had very low sensitivity (8 and 33%, respectively) compared to doppler. Conclusions: Concordance of ABI automatic measurements as Omron,and triple with doppler was poor, and they do not seem suitable for screening for PAD in primary care consultations. (C) 2013 Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:335 / 340
页数:6
相关论文
共 22 条
[1]   Peripheral arterial disease study (PERART): Prevalence and predictive values of asymptomatic peripheral arterial occlusive disease related to cardiovascular morbidity and mortality [J].
Alzamora, Maria Teresa ;
Baena-Diez, Jose Miguel ;
Sorribes, Marta ;
Fores, Rosa ;
Toran, Pere ;
Vicheto, Marisa ;
Pera, Guillem ;
Reina, Maria Dolores ;
Albaladejo, Carlos ;
Llussa, Judith ;
Bundo, Magda ;
Sancho, Amparo ;
Heras, Antonio ;
Rubies, Joan ;
Arenillas, Juan Francisco .
BMC PUBLIC HEALTH, 2007, 7 (1)
[2]  
Argimon JM, 2006, METODOS INVESTIGACIO, P343
[3]   Validation of a new method of detecting peripheral artery disease by determination of ankle-brachial index using an automatic blood pressure device [J].
Benchimol, A ;
Bernard, V ;
Pillois, X ;
Hong, NT ;
Benchimol, D ;
Bonnet, J .
ANGIOLOGY, 2004, 55 (02) :127-134
[4]  
British Hypertension Society, AUT BLOOD PRESS MEAS
[5]   Correlation between toe-brachial index and ankle-brachial index in patients with diabetes mellitus type 2 [J].
Bundo, Magdalena ;
Urrea, Magali ;
Munoz, Laura ;
Llussa, Judit ;
Fores, Rosa ;
Toran, Pere .
MEDICINA CLINICA, 2013, 140 (09) :390-394
[6]   Ankle-brachial index in patients with chest pain and suspected acute coronary syndrome [J].
Elduayen Gragera, Javier ;
Munoz Santos, Lorenzo ;
Nogales Asensio, Juan M. ;
Gimenez Saez, Fernando ;
Lopez Minguez, Jose R. ;
Merchan Herrera, Antonio .
MEDICINA CLINICA, 2010, 134 (05) :202-205
[7]   Underdiagnosis of peripheral arterial disease in the spanish population. ARTPER study [J].
Fores Raurell, Rosa ;
Alzamora Sas, M. Teresa ;
Baena Diez, Jose Miguel ;
Pera Blanco, Guillem ;
Toran Monserrat, Pere ;
Ingla Mas, Jordi .
MEDICINA CLINICA, 2010, 135 (07) :306-309
[8]  
Fowkes FGR, 2008, JAMA-J AM MED ASSOC, V300, P197, DOI 10.1001/jama.300.2.197
[9]   Comparison of the Automated Oscillometric Method With the Gold Standard Doppler Ultrasound Method to Access the Ankle-Brachial Pressure Index [J].
Hamel, Jean-Francois ;
Foucaud, David ;
Fanello, Serge .
ANGIOLOGY, 2010, 61 (05) :487-491
[10]   The correlation of ankle oscillometric blood pressures and segmental pulse volumes to Doppler systolic pressures in arterial occlusive disease [J].
Lee, BY ;
Campbell, JS ;
Berkowitz, P .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (01) :116-122