Determination of optimal blowing-to-suction flow ratio in mechanized excavation face with wall-mounted swirling ventilation using numerical simulations

被引:13
作者
Gao, Runze [1 ]
Wang, Pengfei [2 ,3 ]
Li, Yongjun [2 ]
Liu, Ronghua [1 ,3 ]
机构
[1] Hunan Univ Sci & Technol, Sch Resource Environm & Safety Engn, Xiangtan 411201, Peoples R China
[2] Hunan Univ Sci Technol, Work Safety Key Lab Prevent & Control Gas & Roof, Xiangtan 411201, Peoples R China
[3] Hunan Univ Sci Technol, Hunan Prov Key Lab Safe Min Tech Coal Mines, Xiangtan 411201, Peoples R China
基金
中国国家自然科学基金;
关键词
Mechanized excavation face; Wall-mounted swirling ventilation; Blowing-to-suction flow ratio; Airflow field; Dust; DUST-SUPPRESSION; AIR-CURTAIN; ATOMIZATION CHARACTERISTICS; STRUCTURAL PARAMETERS; INSTALLATION POSITION; PRESSURE; CFD; PERFORMANCE; SPRAY; EFFICIENCY;
D O I
10.1007/s40789-020-00384-3
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wall-mounted swirling ventilation is a new type of system in mechanized excavation faces with a dust suppression performance that is closely related to the blowing-to-suction flow ratio. Physical and simulation models were developed according to the No. C103 mechanized excavation face in the Nahe Coal Mine of the Baise Mining Bureau, Guangxi Province to optimize the blowing-to-suction flow ratio for wall-mounted swirling ventilation. Both the k-epsilon turbulence model and the discrete phase model were utilized to simulate airflow field structures and dust concentration distribution patterns at various blowing-to-suction flow ratios. The results suggest that higher blowing-to-suction flow ratios increase the airflow field disturbance around the working face and weaken the intensity of the axial air curtain. On the other hand, both the intensity of the radial air curtain and the dust suppression effect are enhanced. At a blowing-to-suction flow ratio of 0.8, the wall-mounted swirling ventilation system achieved the most favorable dust suppression performance. Both the total dust and respirable dust had their lowest concentrations with maximum efficiencies of reducing both types at 90.33% and 87.16%, respectively.
引用
收藏
页码:248 / 264
页数:17
相关论文
共 52 条
[1]  
Aminossadati S.M., 2008, 12 USNORTH AM MINE V, P253
[2]   Application of inherent safety principles to dust explosion prevention and mitigation [J].
Amyotte, Paul R. ;
Pegg, Michael J. ;
Khan, Faisal I. .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2009, 87 (01) :35-39
[3]   Modeling subway air flow using CFD [J].
Camelli, Fernando E. ;
Byrne, Greg ;
Loehner, Rainald .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2014, 43 :20-31
[4]   The diffusion and pollution mechanisms of airborne dusts in fully-mechanized excavation face at mesoscopic scale based on CFD-DEM [J].
Cheng, Weimin ;
Yu, Haiming ;
Zhou, Gang ;
Nie, Wen .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2016, 104 :240-253
[5]   Modular ventilation with twin air curtains for reducing dispersed pollution [J].
Ciocanea, Adrian ;
Dragomirescu, Andrei .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2013, 37 :180-198
[6]  
Fu J., 2008, J XIANGTAN NORMAL U, V30, P50
[7]   Monte Carlo simulation of micron size spherical particle removal and resuspension from substrate under fluid flows [J].
Goldasteh, Iman ;
Ahmadi, Goodarz ;
Ferro, Andrea R. .
JOURNAL OF AEROSOL SCIENCE, 2013, 66 :62-71
[8]   Pattern characterization concerning spatial and temporal evolution of dust pollution associated with two typical ventilation methods at fully mechanized excavation faces in rock tunnels [J].
Hua, Yun ;
Nie, Wen ;
Cai, Peng ;
Liu, Yanghao ;
Peng, Huitian ;
Liu, Qiang .
POWDER TECHNOLOGY, 2018, 334 :117-131
[9]  
Jiang Z., 2015, Coal Sci Technol, V43, P54
[10]  
Kim SE, 1997, ANSYS FLUENT MODELIN, P259, DOI [10.1007/978-94-011, DOI 10.1007/978-94-011]