Analytic Global Regularized Backscatter Quantitative Ultrasound

被引:21
作者
Jafarpisheh, Noushin [1 ]
Hall, Timothy J. [2 ]
Rivaz, Hassan [1 ,3 ]
Rosado-Mendez, Ivan M. [4 ]
机构
[1] Concordia Univ, Dept Elect & Comp Engn, Montreal, PQ H3G 1M8, Canada
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[3] Concordia Univ, PERFORM Ctr, Montreal, PQ H3G 1M8, Canada
[4] Univ Nacl Autonoma Mexico, Inst Fis, Dept Fis Expt, Coyoacan 04510, Mexico
基金
美国国家卫生研究院; 加拿大自然科学与工程研究理事会;
关键词
Attenuation; Backscatter; Algebra; Cost function; Ultrasonic imaging; Acoustics; Phantoms; backscatter coefficient; global quantitative ultrasound (QUS); regularization; ACOUSTIC SCATTERING SOURCES; NORMAL RENAL PARENCHYMA; COEFFICIENT MEASUREMENTS; REFERENCE PHANTOM; IN-VIVO; ATTENUATION; PARAMETERS; MICROSTRUCTURE; ANISOTROPY; FEATURES;
D O I
10.1109/TUFFC.2020.3042942
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Although a variety of techniques have been developed to reduce the appearance of B-mode speckle, quantitative ultrasound (QUS) aims at extracting the hidden properties of the tissue. Herein, we propose two novel techniques to accurately and precisely estimate two important QUS parameters, namely, the average attenuation coefficient and the backscatter coefficient. Both the techniques optimize a cost function that incorporates data and continuity constraint terms, which we call AnaLytical Global rEgularized BackscatteR quAntitative ultrasound (ALGEBRA). We propose two versions of ALGEBRA, namely, 1-D- and 2-D-ALGEBRA. In 1-D-ALGEBRA, the regularized cost function is formulated in the axial direction, and the QUS parameters are calculated for one line of radio frequency (RF) echo data. In 2-D-ALGEBRA, the regularized cost function is formulated for the entire image, and the QUS parameters throughout the image are estimated simultaneously. This simultaneous optimization allows 2-D-ALGEBRA to "see" all the data before estimating the QUS parameters. In both the methods, we efficiently optimize the cost functions by casting it as a sparse linear system of equations. As a result of this efficient optimization, 1-D-ALGEBRA and 2-D-ALGEBRA are, respectively, 600 and 300 times faster than optimization using the dynamic programming (DP) method previously proposed by our group. In addition, the proposed technique has fewer input parameters that require manual tuning. Our results demonstrate that the proposed ALGEBRA methods substantially outperform least-square and DP methods in estimating the QUS parameters in phantom experiments.
引用
收藏
页码:1605 / 1617
页数:13
相关论文
共 52 条
[1]  
[Anonymous], 2010, ULTRASONICS PULSE 2, P61391
[2]  
[Anonymous], 2014, Diagnostic Ultrasound Imaging: Inside out
[3]  
Chahuara H, 2020, IEEE INT ULTRA SYM, P1, DOI [DOI 10.1109/IUS46767.2020.9251584, DOI 10.1109/ius46767.2020.9251584]
[4]   TESTS OF BACKSCATTER COEFFICIENT MEASUREMENT USING BROAD-BAND PULSES [J].
CHEN, JF ;
ZAGZEBSKI, JA ;
MADSEN, EL .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (05) :603-607
[5]  
Coila Andres, 2017, 2017 IEEE International Ultrasonics Symposium (IUS), DOI 10.1109/ULTSYM.2017.8092846
[6]  
Coila A, 2018, I S BIOMED IMAGING, P1018, DOI 10.1109/ISBI.2018.8363744
[7]   Regularized Spectral Log Difference Technique for Ultrasonic Attenuation Imaging [J].
Coila, Andres L. ;
Lavarello, Roberto .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (03) :378-389
[8]   SWTV-ACE: Spatially Weighted Regularization Based Attenuation Coefficient Estimation Method for Hepatic Steatosis Detection [J].
Deeba, Farah ;
Schneider, Caitlin ;
Mohammed, Shahed ;
Honarvar, Mohammad ;
Tam, Edward ;
Salcudean, Septimiu ;
Rohling, Robert .
MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT V, 2019, 11768 :610-618
[9]  
Destrempes F, 2019, IEEE INT ULTRA SYM, P2027, DOI [10.1109/ultsym.2019.8925556, 10.1109/ULTSYM.2019.8925556]
[10]   Structure factor model for understanding the measured backscatter coefficients from concentrated cell pellet biophantoms [J].
Franceschini, Emilie ;
Guillermin, Regine ;
Tourniaire, Franck ;
Roffino, Sandrine ;
Lamy, Edouard ;
Landrier, Jean-Francois .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 135 (06) :3620-3631