Assessing internal fouling during microfiltration using optical coherence tomography and evapoporometry

被引:18
作者
Han, Qi [1 ,2 ,3 ]
Thien An Trinh [1 ,2 ]
Tanis-Kanbur, Melike Begum [1 ,2 ,3 ]
Li, Weiyi [4 ]
Chew, Jia Wei [1 ,2 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore, Singapore
[2] Nanyang Technol Univ, Nanyang Environm & Water Res Inst, Singapore Membrane Technol Ctr, Singapore, Singapore
[3] Nanyang Technol Univ, Interdisciplinary Grad Sch, Singapore, Singapore
[4] Southern Univ Sci & Technol, Sch Environm Sci & Engn, Shenzhen, Guangdong, Peoples R China
关键词
Membrane fouling; Internal fouling; Microfiltration; Pore size distribution; Pore constriction; PORE-SIZE; IN-SITU; MEMBRANE FILTRATION; REVERSE-OSMOSIS; CAKE FILTRATION; PROTEIN; MODEL; ULTRAFILTRATION; SUSPENSIONS; EVOLUTION;
D O I
10.1016/j.memsci.2019.117588
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The internal fouling of membranes is typically presumed and inferred, but the direct characterization of representative samples is challenging. This study targeted to assess internal fouling using the Optical Coherence Tomography (OCT) and Evapoporometry (EP) techniques for real-time monitoring during filtration and off-line measurement of the pore size distributions (PSDs) of the fouled membranes, respectively. The results were validated by atomic force microscopy (AFM) measurements and also the three-mechanism fouling model. The foulant used was the well-studied bovine serum albumin (BSA), while the membranes were three commercially available polymeric microfiltration membranes with similar nominal pore sizes and porosities. Although the OCT affirmed the progressive worsening of internal fouling in real-time, the quantitative comparison of the extents of internal fouling among the three membranes was not possible. As for EP, it was able to quantitatively compare the pore size distributions and average pore diameters to ascertain the different extents of internal fouling. The phenomenological model available was effective in quantitatively comparing the extents of pore-constriction among the three membranes, while AFM tied the worst internal fouling to the most attractive BSA-membrane affinity. More in-depth understanding of internal fouling is warranted to not only recommend better membranes but also facilitate the advancement of models.
引用
收藏
页数:13
相关论文
共 39 条
[1]   Evapoporometry determination of pore-size distribution and pore fouling of hollow fiber membranes [J].
Akhondi, E. ;
Wicaksana, F. ;
Krantz, W. B. ;
Fane, A. G. .
JOURNAL OF MEMBRANE SCIENCE, 2014, 470 :334-345
[2]   Influence of backwashing on the pore size of hollow fiber ultrafiltration membranes [J].
Akhondi, Ebrahim ;
Zamani, Farhad ;
Law, Adrian W. K. ;
Krantz, William B. ;
Fane, Anthony G. ;
Chew, Jia Wei .
JOURNAL OF MEMBRANE SCIENCE, 2017, 521 :33-42
[3]   Improved design and protocol for evapoporometry determination of the pore-size distribution [J].
Akhondi, Ebrahim ;
Zamani, Farhad ;
Chew, Jia Wei ;
Krantz, William B. ;
Fane, Anthony G. .
JOURNAL OF MEMBRANE SCIENCE, 2015, 496 :334-343
[4]  
[Anonymous], 1989, ESSENTIAL STAT
[5]   THE BEHAVIOR OF SUSPENSIONS AND MACROMOLECULAR SOLUTIONS IN CROSS-FLOW MICROFILTRATION [J].
BELFORT, G ;
DAVIS, RH ;
ZYDNEY, AL .
JOURNAL OF MEMBRANE SCIENCE, 1994, 96 (1-2) :1-58
[6]  
Blatt W.F., 1970, CONSEQUENCES CONTROL, P47
[7]  
Bowen WR, 1999, J MEMBRANE SCI, V154, P205
[8]   Protein deposition during cross-flow membrane filtration: AFM studies and flux loss [J].
Bowen, WR ;
Doneva, TA ;
Stoton, JAG .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2003, 27 (2-3) :103-113
[9]   Evolution of Membrane Fouling Revealed by Label-Free Vibrational Spectroscopic Imaging [J].
Chen, Wei ;
Qian, Chen ;
Hong, Wei-Li ;
Cheng, Ji-Xin ;
Yu, Han-Qing .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (17) :9580-9587
[10]   A three mechanism model to describe fouling of microfiltration membranes [J].
Duclos-Orsello, Chase ;
Li, Weiyi ;
Ho, Chia-Chi .
JOURNAL OF MEMBRANE SCIENCE, 2006, 280 (1-2) :856-866