Sequential determination of titratable acidity and tartaric acid in wines by flow injection spectrophotometry

被引:24
作者
Rangel, AOSS [1 ]
Tóth, IV [1 ]
机构
[1] Univ Catolica Portuguesa, Escola Super Biotecnol, P-4200 Porto, Portugal
关键词
flow injection; total acidity; tartaric acid; wine; spectrophotometry;
D O I
10.1039/a707477h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection manifold is proposed for the sequential determination of titratable (total) acidity based on a pseudotitration and of tartaric acid based on the formation of a coloured vanadate complex. The method involves in-line dialysis prior to injection to avoid interference from the sample background absorption in the spectrophotometric detection. The changes in the colour of both reactions were monitored using two flow cells aligned in the optical path of a single spectrophotometer. Wine samples were analysed without any sample pre-treatment; table wines in the range 1-10 g l(-1) (total acidity) and 0.5-4 g l(-1) (tartaric acid) and port mines in the range 1-8 g l(-1) (total acidity) and 0.5-5 g l(-1) (tartaric acid). Sixteen samples can be measured per hour, and the results were comparable to those obtained by reference procedures for both determinations. RSDs (n = 10) generally lower than 3% were obtained.
引用
收藏
页码:661 / 664
页数:4
相关论文
共 50 条
  • [41] Determination of the total acidity in soft drinks using potentiometric sequential injection titration
    van Staden, JF
    Mashamba, MM
    Stefan, RI
    [J]. TALANTA, 2002, 58 (06) : 1109 - 1114
  • [42] Determination of ethanol in liquor by near-infrared spectrophotometry with flow injection
    Tipparat, P
    Lapanantnoppakhun, S
    Jakmunee, J
    Grudpan, K
    [J]. TALANTA, 2001, 53 (06) : 1199 - 1204
  • [43] DETERMINATION OF FREE AND COMBINED RESIDUAL CHLORINE BY FLOW-INJECTION SPECTROPHOTOMETRY
    VERMA, KK
    JAIN, A
    TOWNSHEND, A
    [J]. ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 233 - 240
  • [44] A new approach to dialysis in sequential injection systems: Spectrophotometric determination of L(+)-lactate in wines
    Araujo, AN
    Lima, JLFC
    Saraiva, MLMFS
    Zagatto, EAG
    [J]. AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 1997, 48 (04): : 428 - 432
  • [45] Determination of Chromium(VI) in waste water by Reversed Flow Injection Spectrophotometry
    Su, Ling
    Xie, Hengshen
    [J]. PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING (ICEESD2011), PTS 1-5, 2012, 356-360 : 939 - 942
  • [46] Determination of diphenhydramine hydrochloride in some single tertiary alkylamine pharmaceutical preparations by flow injection spectrophotometry
    Tipparat, P
    Lapanantnoppakhun, S
    Jakmunee, J
    Grudpan, K
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (01) : 105 - 112
  • [47] Voltammetric determination of tartaric acid in wines by electrocatalytic oxidation on a cobalt(II)-phthalocyanine-modified electrode associated with multiway calibration
    Lourenco, Anabel S.
    Nascimento, Raphael F.
    Silva, Amanda C.
    Ribeiro, Williame F.
    Araujo, Mario C. U.
    Oliveira, Severino C. B.
    Nascimento, Valberes B.
    [J]. ANALYTICA CHIMICA ACTA, 2018, 1008 : 29 - 37
  • [48] Multisyringe flow injection analysis (MSFIA) for the automatic determination of total iron in wines
    Phansi, Piyawan
    Danchana, Kaewta
    Ferreira, Sergio L. C.
    Cerda, Victor
    [J]. FOOD CHEMISTRY, 2019, 277 : 261 - 266
  • [49] Facile and sensitive determination of selenium (IV) in pharmaceutical formulations by flow injection spectrophotometry
    Kumar, Kailasa Suresh
    Suvardhan, Kanchi
    Kang, Seong Ho
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 97 (05) : 1927 - 1933
  • [50] DETERMINATION OF CADMIUM IN FOODSTUFFS AND PLANT MATERIALS BY FLOW INJECTION-SPECTROPHOTOMETRY INCLUDING ION-EXCHANGE
    NETO, JAG
    BERGAMIN, H
    SARTINI, RP
    ZAGATTO, EAG
    [J]. ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) : 343 - 349