Gravity-driven microfluidic assay for digital enumeration of bacteria and for antibiotic susceptibility testing

被引:41
作者
Kao, Yu-Ting [1 ,2 ]
Kaminski, Tomasz S. [1 ]
Postek, Witold [1 ]
Guzowski, Jan [1 ]
Makuch, Karol [1 ]
Ruszczak, Artur [1 ]
von Stetten, Felix [2 ,3 ]
Zengerle, Roland [2 ,3 ]
Garstecki, Piotr [1 ]
机构
[1] Polish Acad Sci, Inst Phys Chem, Kasprzaka 44-52, PL-01224 Warsaw, Poland
[2] Univ Freiburg, Lab MEMS Applicat, IMTEK Dept Microsyst Engn, Georges Koehler Allee 103, D-79110 Freiburg, Germany
[3] Hahn Schickard, Georges Koehler Allee 103, D-79110 Freiburg, Germany
关键词
MINIMUM INHIBITORY CONCENTRATION; ANTIMICROBIAL SUSCEPTIBILITY; STEP-EMULSIFICATION; HYDROCHLORIDE FORMS; QUANTIFICATION; TETRACYCLINE; SURFACTANTS; SOLUBILITY; VISCOSITY; LIBRARIES;
D O I
10.1039/c9lc00684b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The alarming dynamics of antibiotic-resistant infections calls for the development of rapid and point-of-care (POC) antibiotic susceptibility testing (AST) methods. Here, we demonstrated the first completely stand-alone microfluidic system that allowed the execution of digital enumeration of bacteria and digital antibiograms without any specialized microfluidic instrumentation. A four-chamber gravity-driven step emulsification device generated similar to 2000 monodisperse 2 nanoliter droplets with a coefficient of variation of 8.9% of volumes for 95% of droplets within less than 10 minutes. The manual workload required for droplet generation was limited to the sample preparation, the deposition into the sample inlet of the chip and subsequent orientation of the chip vertically without an additional pumping system. The use of shallow chambers imposing a 2D droplet arrangement provided superior stability of the droplets against coalescence and minimized the leakage of the reporter viability dye between adjacent droplets during long-term culture. By using resazurin as an indicator of the growth of bacteria, we were also able to reduce the assay time to similar to 5 hours compared to 20 hours using the standard culture-based test.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 49 条
  • [1] Colorimetric and Electrochemical Bacteria Detection Using Printed Paper- and Transparency-Based Analytic Devices
    Adkins, Jaclyn A.
    Boehle, Katherine
    Friend, Colin
    Chamberlain, Briana
    Bisha, Bledar
    Henry, Charles S.
    [J]. ANALYTICAL CHEMISTRY, 2017, 89 (06) : 3613 - 3621
  • [2] Universal microfluidic platform for bioassays in anchored droplets
    Amselem, Gabriel
    Guermonprez, Cyprien
    Drogue, Benoit
    Michelin, Sebastien
    Baroud, Charles N.
    [J]. LAB ON A CHIP, 2016, 16 (21) : 4200 - 4211
  • [3] Clinical and financial benefits of rapid bacterial identification and antimicrobial susceptibility testing
    Barenfanger, J
    Drake, C
    Kacich, G
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (05) : 1415 - 1418
  • [4] Growing microbes in millifluidic droplets
    Boitard, Laurent
    Cottinet, Denis
    Bremond, Nicolas
    Baudry, Jean
    Bibette, Jerome
    [J]. ENGINEERING IN LIFE SCIENCES, 2015, 15 (03): : 318 - 326
  • [5] Solubility of Antibiotics in Different Solvents. Part II. Non-Hydrochloride Forms of Tetracycline and Ciprofloxacin
    Caco, Ana I.
    Varanda, Fatima
    Pratas de Melo, Maria J.
    Dias, Ana M. A.
    Dohrn, Ralf
    Marrucho, Isabel M.
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (21) : 8083 - 8089
  • [6] Oxygen transfer effects on recombinant benzaldehyde lyase production
    Çalik, P
    Yilgör, P
    Ayhan, P
    Demir, AS
    [J]. CHEMICAL ENGINEERING SCIENCE, 2004, 59 (22-23) : 5075 - 5083
  • [7] Antimicrobial Susceptibility Testing Using High Surface-to-Volume Ratio Microchannels
    Chen, Chia Hsiang
    Lu, Yi
    Sin, Mandy L. Y.
    Mach, Kathleen E.
    Zhang, Donna D.
    Gau, Vincent
    Liao, Joseph C.
    Wong, Pak Kin
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (03) : 1012 - 1019
  • [8] Rapid screening of antibiotic toxicity in an automated microdroplet system
    Churski, Krzysztof
    Kaminski, Tomasz S.
    Jakiela, Slawomir
    Kamysz, Wojciech
    Baranska-Rybak, Wioletta
    Weibel, Douglas B.
    Garstecki, Piotr
    [J]. LAB ON A CHIP, 2012, 12 (09) : 1629 - 1637
  • [9] A self-loading microfluidic device for determining the minimum inhibitory concentration of antibiotics
    Cira, Nate J.
    Ho, Jack Y.
    Dueck, Megan E.
    Weibel, Douglas B.
    [J]. LAB ON A CHIP, 2012, 12 (06) : 1052 - 1059
  • [10] Cockerill F. R., 2016, M100S CLSI