Topography and longitudinal chromatic aberration characterizations of refractive-diffractive multifocal intraocular lenses

被引:41
作者
Loicq, Jerome [1 ]
Willet, Nicolas [2 ]
Gatinel, Damien [3 ]
机构
[1] Univ Liege, STAR Inst, Ctr Spatial Liege, Av Pre Aily, B-4031 Angleur, Belgium
[2] Univ Liege, Dept Chem, Liege, Belgium
[3] Fdn Rothschild Hosp, Paris, France
关键词
EXTENDED DEPTH; PERFORMANCE;
D O I
10.1016/j.jcrs.2019.06.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Most optical systems present chromatic aberration quantified along the optical axis by the longitudinal chromatic aberration (LCA). LCA is controlled by the biomaterial Abbe number combined with diffractive effects, driven by the intraocular lens (IOL) topography. This study experimentally aimed at describing the effect in vitro of LCA in diffractive multifocal IOLs, with the help of dedicated optical benches and topographic characterization. Setting: Centre Spatial de Liege, Belgium. Design: Optical and topology analysis of various multifocal diffractive IOLs. Methods: Seven diffractive multifocal IOLs, available on the market and exhibiting different diffractive profiles, made from various biomaterials, were characterized under different wavelengths. Results: Through-focus modulation transfer function (MTF) curves and IOL diffraction efficiency depends on the incident light wavelength. In this study, the topology properties of various multi-focal IOLs were investigated and their characteristics were correlated to their optical behavior for various wavelengths. Chromatic properties and their origins were then compared. As expected, diffractive and refractive effects were found to act in opposite ways, and could be partially or completely compensated. Conclusions: The LCA of each of the IOLs was evaluated in vitro. In most of the multifocal IOLs studied, some of the foci were found to be refractive, whereas others were diffractive. Although the results were not extrapolated to clinical relevance, it was shown, in some of the cases, that LCA could be fully compensated. (C) 2019 ASCRS and ESCRS
引用
收藏
页码:1650 / 1659
页数:10
相关论文
共 15 条
  • [1] Optical bench performance of 3 trifocal intraocular lenses
    Carson, Daniel
    Xu, Zaiwei
    Alexander, Elsinore
    Choi, Myoung
    Zhao, Zeyu
    Hong, Xin
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09) : 1361 - 1367
  • [2] SPECTRAL PROPERTIES OF MULTIORDER DIFFRACTIVE LENSES
    FAKLIS, D
    MORRIS, GM
    [J]. APPLIED OPTICS, 1995, 34 (14) : 2462 - 2468
  • [3] Clinically Relevant Optical Properties of Bifocal, Trifocal, and Extended Depth of Focus Intraocular Lenses
    Gatinel, Damien
    Loicq, Jerome
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (04) : 273 - +
  • [4] Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench
    Gatinel, Damien
    Houbrechts, Yvette
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07) : 1093 - 1099
  • [5] Design and qualification of a diffractive trifocal optical profile for intraocular lenses
    Gatinel, Damien
    Pagnoulle, Christophe
    Houbrechts, Yvette
    Gobin, Laure
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11) : 2060 - 2067
  • [6] International Organization for Standardization, 2003, 119792 ISO
  • [7] International Organization for Standardization (ISO), 2006, 119799 ISO
  • [8] Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline Lens
    Kohnen, Thomas
    Herzog, Michael
    Hemkeppler, Eva
    Schonbrunn, Sabrina
    De Lorenzo, Nina
    Petermann, Kerstin
    Bohm, Myriam
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 184 : 52 - 62
  • [9] Optical Quality Differences Between Three Multifocal Intraocular Lenses: Bifocal Low Add, Bifocal Moderate Add, and Trifocal
    Madrid-Costa, David
    Ruiz-Alcocer, Javier
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Montes-Mico, Robert
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (11) : 749 - +
  • [10] Extended depth of focus intraocular lens: chromatic performance
    Millan, Maria S.
    Vega, Fidel