Non-contact, automated cardiac pulse measurements using video imaging and blind source separation

被引:1156
作者
Poh, Ming-Zher [1 ,2 ]
McDuff, Daniel J. [2 ]
Picard, Rosalind W. [2 ]
机构
[1] Harvard Univ, MIT, Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[2] MIT, Media Lab, Cambridge, MA 02139 USA
关键词
INDEPENDENT COMPONENT ANALYSIS; FACE DETECTION; HEART-RATE; PHOTOPLETHYSMOGRAPHY; WAVELENGTH; ARTIFACTS; LIGHT;
D O I
10.1364/OE.18.010762
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Remote measurements of the cardiac pulse can provide comfortable physiological assessment without electrodes. However, attempts so far are non-automated, susceptible to motion artifacts and typically expensive. In this paper, we introduce a new methodology that overcomes these problems. This novel approach can be applied to color video recordings of the human face and is based on automatic face tracking along with blind source separation of the color channels into independent components. Using Bland-Altman and correlation analysis, we compared the cardiac pulse rate extracted from videos recorded by a basic webcam to an FDA-approved finger blood volume pulse (BVP) sensor and achieved high accuracy and correlation even in the presence of movement artifacts. Furthermore, we applied this technique to perform heart rate measurements from three participants simultaneously. This is the first demonstration of a low-cost accurate video-based method for contact-free heart rate measurements that is automated, motion-tolerant and capable of performing concomitant measurements on more than one person at a time. (C) 2010 Optical Society of America
引用
收藏
页码:10762 / 10774
页数:13
相关论文
共 33 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Cardoso JF, 1998, INT CONF ACOUST SPEE, P1941, DOI 10.1109/ICASSP.1998.681443
[4]   High-order contrasts for independent component analysis [J].
Cardoso, JF .
NEURAL COMPUTATION, 1999, 11 (01) :157-192
[5]   RETRACTED: Artifacts and noise removal in electrocardiograms using independent component analysis (Retracted Article) [J].
Chawla, M. P. S. ;
Verma, H. K. ;
Kumar, Vinod .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 129 (02) :278-281
[6]   Hybrid-boost learning for multi-pose face detection and facial expression recognition [J].
Chen, Hsiuao-Ying ;
Huang, Chung-Lin ;
Fu, Chih-Ming .
PATTERN RECOGNITION, 2008, 41 (03) :1173-1185
[7]   INDEPENDENT COMPONENT ANALYSIS, A NEW CONCEPT [J].
COMON, P .
SIGNAL PROCESSING, 1994, 36 (03) :287-314
[8]   High heart rate: a cardiovascular risk factor? [J].
Cook, Stephane ;
Togni, Mario ;
Schaub, Marcus C. ;
Wenaweser, Peter ;
Hess, Otto M. .
EUROPEAN HEART JOURNAL, 2006, 27 (20) :2387-2393
[9]   INVIVO REFLECTANCE OF BLOOD AND TISSUE AS A FUNCTION OF LIGHT WAVELENGTH [J].
CUI, W ;
OSTRANDER, LE ;
LEE, BY .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (06) :632-639
[10]   Thermistor at a Distance: Unobtrusive Measurement of Breathing [J].
Fei, Jin ;
Pavlidis, Ioannis .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (04) :988-998