Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
[41]   Simultaneous determination of capsid proteins in nine-valent human papilloma virus vaccines by liquid chromatography tandem mass spectrometry [J].
Long, Zhen ;
Nie, Jianhui ;
Li, Xiuling ;
Li, Xiaoyu ;
Huang, Weijin ;
Li, Changkun ;
Li, Yueqi ;
Huang, Taohong .
JOURNAL OF SEPARATION SCIENCE, 2021, 44 (02) :557-564
[42]   A simultaneous quantitative method for vitamins A, D and E in human serum using liquid chromatography-tandem mass spectrometry [J].
Albahrani, Ali A. ;
Rotarou, Victor ;
Roche, Peter J. ;
Greaves, Ronda F. .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2016, 159 :41-53
[43]   Simultaneous Measurement of Sex Steroid Hormones in Largemouth Bass (Micropterus salmoides) Plasma by Application of Liquid Chromatography-Tandem Mass Spectrometry [J].
Dang, Viet D. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2021, 59 (01) :7-14
[44]   Vortex-assisted liquid-liquid microextraction combined with liquid chromatography tandem mass spectrometry for simultaneous determination of cardiovascular drugs in human plasma [J].
Castro e Souza, Mateus Araujo ;
Araujo Reis, Naialy Fernandes ;
Placido de Oliveira Pacheco, Isabella Cristina ;
Parreiras Martins, Maria Auxiliadora ;
Gloria, Maria Beatriz A. ;
Pianetti, Gerson Antonio ;
Fernandes, Christian .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 217
[45]   Simultaneous determination of 14 sulfonamides and tetracyclines in biogas plants by liquid-liquid-extraction and liquid chromatography tandem mass spectrometry [J].
Spielmeyer, Astrid ;
Ahlborn, Jenny ;
Hamscher, Gerd .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (11) :2513-2524
[46]   Determination of sulfonamides in beeswax by liquid chromatography coupled to tandem mass spectrometry [J].
Mitrowska, Kamila ;
Antczak, Maja .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1006 :179-186
[47]   Simultaneous determination of 14 sulfonamides and tetracyclines in biogas plants by liquid-liquid-extraction and liquid chromatography tandem mass spectrometry [J].
Astrid Spielmeyer ;
Jenny Ahlborn ;
Gerd Hamscher .
Analytical and Bioanalytical Chemistry, 2014, 406 :2513-2524
[48]   Determination of glucosamine in horse plasma by liquid chromatography tandem mass spectrometry [J].
Beaudry, Francis ;
Vachon, Pascal .
BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (01) :1-4
[49]   Determination of cortisol and cortisone in human saliva by a liquid chromatography-tandem mass spectrometry method [J].
Henriques Vieira, Jose Gilberto ;
Nakamura, Odete Hirata ;
Carvalho, Valdemir Melechko .
ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2014, 58 (08) :844-850
[50]   Serum steroid profiling for Congenital Adrenal Hyperplasia using liquid chromatography-tandem mass spectrometry [J].
Rossi, Claudia ;
Calton, Lisa ;
Hammond, Gareth ;
Brown, Heather A. ;
Wallace, A. Michael ;
Sacchetta, Paolo ;
Morris, Michael .
CLINICA CHIMICA ACTA, 2010, 411 (3-4) :222-228