Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
[31]   Tear Film Steroid Profiling in Dry Eye Disease by Liquid Chromatography Tandem Mass Spectrometry [J].
Pieragostino, Damiana ;
Agnifili, Luca ;
Cicalini, Ilaria ;
Calienno, Roberta ;
Zucchelli, Mirco ;
Mastropasqua, Leonardo ;
Sacchetta, Paolo ;
Del Boccio, Piero ;
Rossi, Claudia .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2017, 18 (07)
[32]   Simultaneous Determination of Seventeen Sulfonamide Residues in Chickens by Liquid Chromatography-Electrospray Tandem Mass Spectrometry [J].
Dong Dan ;
Shao Bing ;
Wu Yongning ;
Wu Guohua ;
Xue Ying ;
Xu Shukun ;
Tu Xiaoming ;
Zhang Yanfeng .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (04) :404-407
[33]   Simultaneous determination of bisphenol A and estrogens in hair samples by liquid chromatography-electrospray tandem mass spectrometry [J].
Lee, Chaelin ;
Kim, Chong Hyeak ;
Kim, Sunghwan ;
Cho, Sung-Hee .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1058 :8-13
[34]   Direct quantification of steroid glucuronides in human urine by liquid chromatography-electrospray tandem mass spectrometry [J].
Pozo, Oscar J. ;
Van Eenoo, Peter ;
Van Thuyne, Wim ;
Deventer, Koen ;
Delbeke, Frans T. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1183 (1-2) :108-118
[35]   Simultaneous determination of all aminobutyric acids by chiral derivatization and liquid chromatography-tandem mass spectrometry [J].
Eiji Sugiyama ;
Mao Nakamura ;
Hajime Mizuno ;
Aogu Furusho ;
Kenichiro Todoroki .
Analytical Sciences, 2023, 39 :463-472
[36]   Simultaneous determination of all aminobutyric acids by chiral derivatization and liquid chromatography-tandem mass spectrometry [J].
Sugiyama, Eiji ;
Nakamura, Mao ;
Mizuno, Hajime ;
Furusho, Aogu ;
Todoroki, Kenichiro .
ANALYTICAL SCIENCES, 2023, 39 (04) :463-472
[37]   Simultaneous determination of 3-mercaptopyruvate and cobinamide in plasma by liquid chromatography-tandem mass spectrometry [J].
Stutelberg, Michael W. ;
Dzisam, Joseph K. ;
Monteil, Alexandre R. ;
Petrikovics, Ilona ;
Boss, Gerry R. ;
Patterson, Steven E. ;
Rockwood, Gary A. ;
Logue, Brian A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1008 :181-188
[38]   Electrospray ionization mass spectrometry of tetrodotoxin and its analogs: Liquid chromatography/mass spectrometry, tandem mass spectrometry, and liquid chromatography/tandem mass spectrometry [J].
Shoji, Y ;
Yotsu-Yamashita, M ;
Miyazawa, T ;
Yasumoto, T .
ANALYTICAL BIOCHEMISTRY, 2001, 290 (01) :10-17
[39]   Determination of intact oxaliplatin in human plasma using high performance liquid chromatography-tandem mass spectrometry [J].
Zhang, Wenjiang ;
Seymour, Lesley ;
Chen, Eric X. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (02) :277-282
[40]   Simultaneous determination of rivaroxaban and dabigatran levels in human plasma by high-performance liquid chromatography-tandem mass spectrometry [J].
Korostelev, Marie ;
Bihan, Kevin ;
Ferreol, Lison ;
Tissot, Nadine ;
Hulot, Jean-Sebastien ;
Funck-Brentano, Christian ;
Zahra, Noel .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 100 :230-235