Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [21] Noninvasive determination of human cortisol and dehydroepiandrosterone sulfate using liquid chromatography-tandem mass spectrometry
    Zhimin (Tim) Cao
    Stephanie E. Wemm
    Liqiao Han
    David C. Spink
    Edelgard Wulfert
    Analytical and Bioanalytical Chemistry, 2019, 411 : 1203 - 1210
  • [22] Determination of mepitiostane metabolites in human urine by liquid chromatography/tandem mass spectrometry for sports drug testing
    Okano, Masato
    Sato, Mitsuhiko
    Kojima, Asami
    Kageyama, Shinji
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 115 : 236 - 244
  • [23] Simultaneous quantification of four native estrogen hormones at trace levels in human cerebrospinal fluid using liquid chromatography-tandem mass spectrometry
    Nguyen, Hien P.
    Li, Li
    Gatson, Joshua W.
    Maass, David
    Wigginton, Jane G.
    Simpkins, James W.
    Schug, Kevin A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) : 830 - 837
  • [24] Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry
    Zhou, Hui
    Wang, Yuesong
    Gatcombe, Matthew
    Farris, Jacob
    Botelho, Julianne C.
    Caudill, Samuel P.
    Vesper, Hubert W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (25) : 5943 - 5954
  • [25] Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for the Determination of Olanzapine in Human Urine
    Anil Kumar Rangachar Urdigere
    Bhasakra Laxmaiah Besagarahally
    Kanakapura Basavaiah
    Arabian Journal for Science and Engineering, 2012, 37 : 1381 - 1387
  • [26] Determination of fluspirilene in human plasma by liquid chromatography tandem mass spectrometry with electrospray ionisation
    Swart, KJ
    Sutherland, FCH
    van Essen, GH
    Hundt, HKL
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) : 219 - 227
  • [27] Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry
    Hui Zhou
    Yuesong Wang
    Matthew Gatcombe
    Jacob Farris
    Julianne C. Botelho
    Samuel P. Caudill
    Hubert W. Vesper
    Analytical and Bioanalytical Chemistry, 2017, 409 : 5943 - 5954
  • [28] Simultaneous Quantification of Erlotinib, Gefitinib, and Imatinib in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry
    Chahbouni, A.
    den Burger, J. C. G.
    Vos, R. M.
    Sinjewel, A.
    Wilhelm, A. J.
    THERAPEUTIC DRUG MONITORING, 2009, 31 (06) : 683 - 687
  • [29] Determination of 17α-methyltestosterone in Bovine Serum Using Liquid Chromatography Tandem Mass Spectrometry
    Regal, Patricia
    Nebot, Carolina
    Vazquez, Beatriz I.
    Cepeda, Alberto
    Fente, Cristina A.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2010, 18 (01) : 51 - 57
  • [30] Direct quantification of steroid glucuronides in human urine by liquid chromatography-electrospray tandem mass spectrometry
    Pozo, Oscar J.
    Van Eenoo, Peter
    Van Thuyne, Wim
    Deventer, Koen
    Delbeke, Frans T.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1183 (1-2) : 108 - 118