Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
[21]   Noninvasive determination of human cortisol and dehydroepiandrosterone sulfate using liquid chromatography-tandem mass spectrometry [J].
Cao, Zhimin ;
Wemm, Stephanie E. ;
Han, Liqiao ;
Spink, David C. ;
Wulfert, Edelgard .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (06) :1203-1210
[22]   Simultaneous quantification of four native estrogen hormones at trace levels in human cerebrospinal fluid using liquid chromatography-tandem mass spectrometry [J].
Nguyen, Hien P. ;
Li, Li ;
Gatson, Joshua W. ;
Maass, David ;
Wigginton, Jane G. ;
Simpkins, James W. ;
Schug, Kevin A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) :830-837
[23]   Determination of fluspirilene in human plasma by liquid chromatography tandem mass spectrometry with electrospray ionisation [J].
Swart, KJ ;
Sutherland, FCH ;
van Essen, GH ;
Hundt, HKL ;
Hundt, AF .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :219-227
[24]   Sensitive Liquid Chromatography–Tandem Mass Spectrometry Method for the Determination of Olanzapine in Human Urine [J].
Anil Kumar Rangachar Urdigere ;
Bhasakra Laxmaiah Besagarahally ;
Kanakapura Basavaiah .
Arabian Journal for Science and Engineering, 2012, 37 :1381-1387
[25]   Determination of mepitiostane metabolites in human urine by liquid chromatography/tandem mass spectrometry for sports drug testing [J].
Okano, Masato ;
Sato, Mitsuhiko ;
Kojima, Asami ;
Kageyama, Shinji .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 115 :236-244
[26]   Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry [J].
Zhou, Hui ;
Wang, Yuesong ;
Gatcombe, Matthew ;
Farris, Jacob ;
Botelho, Julianne C. ;
Caudill, Samuel P. ;
Vesper, Hubert W. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (25) :5943-5954
[27]   Simultaneous measurement of total estradiol and testosterone in human serum by isotope dilution liquid chromatography tandem mass spectrometry [J].
Hui Zhou ;
Yuesong Wang ;
Matthew Gatcombe ;
Jacob Farris ;
Julianne C. Botelho ;
Samuel P. Caudill ;
Hubert W. Vesper .
Analytical and Bioanalytical Chemistry, 2017, 409 :5943-5954
[28]   Simultaneous Quantification of Erlotinib, Gefitinib, and Imatinib in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry [J].
Chahbouni, A. ;
den Burger, J. C. G. ;
Vos, R. M. ;
Sinjewel, A. ;
Wilhelm, A. J. .
THERAPEUTIC DRUG MONITORING, 2009, 31 (06) :683-687
[29]   Determination of anabolic androgenic steroids as imidazole carbamate derivatives in human urine using liquid chromatography-tandem mass spectrometry [J].
Fragkaki, Argyro G. ;
Petropoulou, Georgia ;
Athanasiadou, Ioanna ;
Kiousi, Polyxeni ;
Kioukia-Fougia, Nassia ;
Archontaki, Helen ;
Bakeas, Evangelos ;
Angelis, Yiannis S. .
JOURNAL OF SEPARATION SCIENCE, 2020, 43 (11) :2154-2161
[30]   Determination of 17α-methyltestosterone in Bovine Serum Using Liquid Chromatography Tandem Mass Spectrometry [J].
Regal, Patricia ;
Nebot, Carolina ;
Vazquez, Beatriz I. ;
Cepeda, Alberto ;
Fente, Cristina A. .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2010, 18 (01) :51-57