Simultaneous determination of steroid composition of human testicular fluid using liquid chromatography tandem mass spectrometry

被引:44
|
作者
Zhao, M
Baker, SD
Yan, XH
Zhao, YY
Wright, WW
Zirkin, BR
Jarow, JP
机构
[1] Johns Hopkins Univ, Sch Med, Dept Urol, Baltimore, MD 21287 USA
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Biochem & Mol Biol, Div Reprod Biol, Baltimore, MD 21209 USA
[3] Johns Hopkins Univ, Sch Med, Sidney Kimmel Comprehens Canc Ctr, Div Expt Therapeut, Baltimore, MD 21287 USA
关键词
testes; testosterone; dihydrotestosterone; estradiol; mass spectrometry;
D O I
10.1016/j.steroids.2004.05.020
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra(TM) C-18 (150 mm x 2.1 mm i.d., 3.5 mum) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 mul, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 12.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [1] Determination of steroid profile in hair by liquid chromatography tandem mass spectrometry
    Gomez-Gomez, Alex
    Pozo, Oscar J.
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1624 (1624)
  • [2] Simultaneous determination of hydrochlorothiazide and valsartan in human plasma by liquid chromatography/tandem mass spectrometry
    Liu, Fei
    Zhang, Jundong
    Xu, Yu
    Gao, Shu
    Guo, Qingxiang
    ANALYTICAL LETTERS, 2008, 41 (08) : 1348 - 1365
  • [3] Determination of 19 Steroid Hormones in Human Serum and Urine Using Liquid Chromatography-Tandem Mass Spectrometry
    Li, Zhong-Min
    Kannan, Kurunthachalam
    TOXICS, 2022, 10 (11)
  • [4] Simultaneous determination of endogenous steroid hormones in human and animal plasma and serum by liquid or gas chromatography coupled to tandem mass spectrometry
    Abdel-Khalik, Jonas
    Bjorklund, Erland
    Hansen, Martin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 928 : 58 - 77
  • [5] Determination of ribavirin in human serum using liquid chromatography tandem mass spectrometry
    van der Lijke, Henk
    Alffenaar, Jan-Willem C.
    Kok, Wim Th.
    Greijdanus, Ben
    Uges, Donald R. A.
    TALANTA, 2012, 88 : 385 - 390
  • [6] Determination of the steroid profile in alternative matrices by liquid chromatography tandem mass spectrometry
    Gomez-Gomez, Alex
    Miranda, Jezid
    Feixas, Georgina
    Arranz Betegon, Angela
    Crispi, Fatima
    Gratacos, Eduard
    Pozo, Oscar J.
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2020, 197
  • [7] Determination of captopril in human plasma by liquid chromatography/tandem mass spectrometry
    Du, Meiju
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3245 - 3255
  • [8] Determination of steroid estrogens in wastewater by high performance liquid chromatography - tandem mass spectrometry
    Koha, Y. K. K.
    Chiu, T. Y.
    Boobis, A.
    Cartmell, E.
    Lester, J. N.
    Scrimshaw, M. D.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1173 (1-2) : 81 - 87
  • [9] Determination of hydrochlorothiazide in human plasma by liquid chromatography/tandem mass spectrometry
    Liu, Fei
    Xu, Yu
    Gao, Shu
    Zhang, Jundong
    Guo, Qingxiang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (05) : 1187 - 1191
  • [10] Sex Steroid Hormone Analysis in Human Tear Fluid Using a Liquid Chromatography-Mass Spectrometry Method
    Robciuc, Alexandra
    Savolainen-Peltonen, Hanna
    Haanpaa, Mikko
    Moilanen, Jukka A. O.
    Mikkola, Tomi S.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (23)