Functionalized Fe3O4/graphene oxide nanocomposites with hairpin aptamers for the separation and preconcentration of trace Pb2+ from biological samples prior to determination by ICP MS

被引:55
|
作者
Shamsipur, Mojtaba [1 ]
Farzin, Leila [2 ,3 ]
Tabrizi, Mahmoud Amouzadeh [4 ]
Sheibani, Shahab [2 ]
机构
[1] Razi Univ, Dept Chem, POB 67149-67346, Kermanshah, Iran
[2] Nucl Sci & Technol Res Inst, Radiat Applicat Res Sch, POB 11365-3486, Tehran, Iran
[3] Univ Tehran, Coll Sci, Sch Chem, Dept Analyt Chem, POB 14174-66191, Tehran, Iran
[4] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, POB 14197-33131, Tehran, Iran
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2017年 / 77卷
关键词
Hairpin aptamer; Magnetic graphene oxide; Lead (II) ion; ICP MS; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT EXTRACTION; HEAVY-METAL IONS; GRAPHENE OXIDE; BIMETALLIC NANOPARTICLES; COLUMN PRECONCENTRATION; ENVIRONMENTAL WATER; SENSITIVE DETECTION; GOLD NANOPARTICLES;
D O I
10.1016/j.msec.2017.03.262
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Lead (Pb) as a topically poisonous metal represents a serious threat to the ecological environment and especially to human beings. Therefore, it is urgent to develop a rapid and reliable monitoring technique for this heavy metal in the environmental samples. In the present study, we have designed a selective and sensitive method for the determination of ultratrace contents of Pb2+ in biological samples, based on the guanine (G)-quadruplex formed by the aptamer with hairpin structure and Pb2+. For this purpose, Pb2+ specific aptamer serving as affinity probe to capture and separate trace amounts of the analyte, was covalently linked to Fe3O4/graphene oxide (GO) surface by using a suitable cross-linking agent. Then, the G-quadruplex complex was formed by the opening of the "neck-ring" of the hairpin structure of aptamer in the presence of Pb2+. Inductively coupled plasma mass spectrometry (ICP-MS) was used for determination of Pb2+ in biological matrices. The analysis conditions were optimized and the performance of the proposed method was investigated. Under optimum conditions, the calibration curve was linear over the range of 03-867.5 mu g L-1 and an enrichment factor (EF) of 50 was obtained. The limit of detection (LOD) was 0.05 mu g L-1 and the relative standard deviation (RSD) for single-sorbent repeatability and sorbent-to-sorbent reproducibility were <4.7% and 8.8% (n = 5), respectively. The accuracy of aptamer-based affinity purification method was confirmed by the analysis of quality control materials (QCMs, Seronorm (TM) Blood REF NO 201505 and Urine REF NO 2525). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:459 / 469
页数:11
相关论文
共 50 条
  • [41] Removal and Preconcentration of Pb(II) Heavy Metal Ion from Water and Waste-Water Samples onto Poly (vinyl alcohol)/polyethyleneimine/Fe3O4 Microfibers Nanocomposite
    Bavel, Elnaz
    Afkhami, Abbas
    Madrakian, Tayebeh
    JOURNAL OF POLYMERS AND THE ENVIRONMENT, 2020, 28 (02) : 614 - 623
  • [42] Diglycolamide-grafted Fe3O4/polydopamine nanomaterial as a novel magnetic adsorbent for preconcentration of rare earth elements in water samples prior to inductively coupled plasma optical emission spectrometry determination
    Li, Fukai
    Gong, Aijun
    Qiu, Lina
    Zhang, Weiwei
    Li, Jingrui
    Liu, Zhe
    CHEMICAL ENGINEERING JOURNAL, 2019, 361 : 1098 - 1109
  • [43] Extraction of Pb2+ from dilute solution by paramagnetic Fe3O4 @ SiO2 @ Clpr-silica @ dithizone solid-phase nanoextractant
    Ma, Jie
    Cheng, Guoliang
    Basov, Sergey
    Zhang, Shuping
    Ji, Tingting
    DESALINATION AND WATER TREATMENT, 2014, 52 (40-42) : 7898 - 7905
  • [44] A new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite film for simultaneous determination of catechol and hydroquinone
    Erogul, Seyma
    Bas, Salih Zeki
    Ozmen, Mustafa
    Yildiz, Salih
    ELECTROCHIMICA ACTA, 2015, 186 : 302 - 313
  • [45] Magnetic magnetite (Fe3O4) nanoparticle synthesis and applications for lead (Pb2+) and chromium (Cr6+) removal from water
    Rajput, Shalini
    Pittman, Charles U., Jr.
    Mohan, Dinesh
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 468 : 334 - 346
  • [46] A regenerable sorbent composed of a zeolite imidazolate framework (ZIF-8), Fe3O4 and graphene oxide for enrichment of atorvastatin and simvastatin prior to their determination by HPLC
    Peng, Jun
    Tian, Huairu
    Du, Qiuzheng
    Hui, Xuanhong
    He, Hua
    MICROCHIMICA ACTA, 2018, 185 (02)
  • [47] Ultrasound-assisted dispersive magnetic solid phase extraction for preconcentration and determination of trace amount of Hg (II) ions from food samples and aqueous solution by magnetic graphene oxide (Fe3O4@ GO/2-PTSC): Central composite design optimization
    Keramat, Akram
    Zare-Dorabei, Rouholah
    ULTRASONICS SONOCHEMISTRY, 2017, 38 : 421 - 429
  • [48] Preparation of Fe3O4@TiO2/graphene oxide magnetic microspheres for microchip-based preconcentration of estrogens in milk and milk powder samples
    Tian, Miaomiao
    Feng, Wei
    Ye, Juanjuan
    Jia, Qiong
    ANALYTICAL METHODS, 2013, 5 (16) : 3984 - 3991
  • [49] Fe3O4@SiO2@Bacillus pumilis: magnetised solid phase bio-extractor for preconcentration of Pb(II) and Cu(II) from water samples
    Erbas, Zeliha
    Soylak, Mustafa
    Ozdemir, Sadin
    Kilinc, Ersin
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2019, 99 (11) : 1112 - 1122
  • [50] Functionalized nano magnetic Fe3O4-SiO2 core-shell as efficient adsorbent for removal of Pb2+ from aqueous solutions
    Baghkumeh, A. Mokhtari
    Faghihian, H.
    Mokhtari, Sh.
    DESALINATION AND WATER TREATMENT, 2017, 78 : 166 - 171