Functionalized Fe3O4/graphene oxide nanocomposites with hairpin aptamers for the separation and preconcentration of trace Pb2+ from biological samples prior to determination by ICP MS

被引:55
|
作者
Shamsipur, Mojtaba [1 ]
Farzin, Leila [2 ,3 ]
Tabrizi, Mahmoud Amouzadeh [4 ]
Sheibani, Shahab [2 ]
机构
[1] Razi Univ, Dept Chem, POB 67149-67346, Kermanshah, Iran
[2] Nucl Sci & Technol Res Inst, Radiat Applicat Res Sch, POB 11365-3486, Tehran, Iran
[3] Univ Tehran, Coll Sci, Sch Chem, Dept Analyt Chem, POB 14174-66191, Tehran, Iran
[4] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, POB 14197-33131, Tehran, Iran
关键词
Hairpin aptamer; Magnetic graphene oxide; Lead (II) ion; ICP MS; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; CLOUD POINT EXTRACTION; HEAVY-METAL IONS; GRAPHENE OXIDE; BIMETALLIC NANOPARTICLES; COLUMN PRECONCENTRATION; ENVIRONMENTAL WATER; SENSITIVE DETECTION; GOLD NANOPARTICLES;
D O I
10.1016/j.msec.2017.03.262
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Lead (Pb) as a topically poisonous metal represents a serious threat to the ecological environment and especially to human beings. Therefore, it is urgent to develop a rapid and reliable monitoring technique for this heavy metal in the environmental samples. In the present study, we have designed a selective and sensitive method for the determination of ultratrace contents of Pb2+ in biological samples, based on the guanine (G)-quadruplex formed by the aptamer with hairpin structure and Pb2+. For this purpose, Pb2+ specific aptamer serving as affinity probe to capture and separate trace amounts of the analyte, was covalently linked to Fe3O4/graphene oxide (GO) surface by using a suitable cross-linking agent. Then, the G-quadruplex complex was formed by the opening of the "neck-ring" of the hairpin structure of aptamer in the presence of Pb2+. Inductively coupled plasma mass spectrometry (ICP-MS) was used for determination of Pb2+ in biological matrices. The analysis conditions were optimized and the performance of the proposed method was investigated. Under optimum conditions, the calibration curve was linear over the range of 03-867.5 mu g L-1 and an enrichment factor (EF) of 50 was obtained. The limit of detection (LOD) was 0.05 mu g L-1 and the relative standard deviation (RSD) for single-sorbent repeatability and sorbent-to-sorbent reproducibility were <4.7% and 8.8% (n = 5), respectively. The accuracy of aptamer-based affinity purification method was confirmed by the analysis of quality control materials (QCMs, Seronorm (TM) Blood REF NO 201505 and Urine REF NO 2525). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:459 / 469
页数:11
相关论文
共 50 条
  • [41] Magnetic Nanocomposites Graphene Oxide/Magnetite + Cobalt Ferrite (GrO/Fe3O4 + CoFe2O4) for Magnetic Hyperthermia
    A. S. Kamzin
    I. M. Obaidat
    V. S. Kozlov
    E. V. Voronina
    V. Narayanaswamy
    I. A. Al-Omari
    Physics of the Solid State, 2021, 63 : 998 - 1008
  • [42] A bucky gel consisting of Fe3O4 nanoparticles, graphene oxide and ionic liquid as an efficient sorbent for extraction of heavy metal ions from water prior to their determination by ICP-OES
    Mohammad Kazem Rofouei
    Sarah Jamshidi
    Shahram Seidi
    Abolfazl Saleh
    Microchimica Acta, 2017, 184 : 3425 - 3432
  • [43] A bucky gel consisting of Fe3O4 nanoparticles, graphene oxide and ionic liquid as an efficient sorbent for extraction of heavy metal ions from water prior to their determination by ICP-OES
    Rofouei, Mohammad Kazem
    Jamshidi, Sarah
    Seidi, Shahram
    Saleh, Abolfazl
    MICROCHIMICA ACTA, 2017, 184 (09) : 3425 - 3432
  • [44] Preparation of magnetic Fe3O4 nanocomposites modified with MnO2, Al2O3, Au and their application for preconcentration of arsenic in river water samples
    Munonde, Tshimangadzo S.
    Maxakato, Nobanathi W.
    Nomngongo, Philiswa N.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2018, 6 (02): : 1673 - 1681
  • [45] A sensitive electrochemical sensor based on Fe3O4 magnetic nanoparticles/chitosan/graphene composite for detection of Pb2+ in aqueous solutions
    Pham, Huyen Ngoc Khanh
    Tran, Luyen Thi
    Vu, Tuan Anh
    Tran, Hoang Vinh
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (11) : 2595 - 2605
  • [46] Application of Fe3O4/graphene oxide composite for the separation of Cs(I) and Sr(II) from aqueous solution
    Wang, Xu
    Yu, Jitao
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (01) : 807 - 813
  • [47] Application of Fe3O4/graphene oxide composite for the separation of Cs(I) and Sr(II) from aqueous solution
    Xu Wang
    Jitao Yu
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 807 - 813
  • [48] Individual and Simultaneous Stripping Voltammetric and Mutual Interference Analysis of Cd2+, Pb2+ and Hg2+ with Reduced Graphene Oxide-Fe3O4 Nanocomposites
    Xiong, Shiquan
    Yang, Bingyi
    Cai, Dongqing
    Qiu, Guannan
    Wu, Zhengyan
    ELECTROCHIMICA ACTA, 2015, 185 : 52 - 61
  • [49] Electrochemical sensor for determination of hydroxylamine using functionalized Fe3O4 nanoparticles and graphene oxide modified screen-printed electrode
    Tashakkorian, Hamed
    Aflatoonian, Behnaz
    Jahani, Peyman Mohammadzadeh
    Aflatoonian, Mohammad Reza
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, 12 (01): : 71 - 79
  • [50] Magnetic Nanocomposites Graphene Oxide/Magnetite plus Cobalt Ferrite (GrO/Fe3O4 + CoFe2O4) for Magnetic Hyperthermia
    Kamzin, A. S.
    Obaidat, I. M.
    Kozlov, V. S.
    Voronina, E. V.
    Narayanaswamy, V
    Al-Omari, I. A.
    PHYSICS OF THE SOLID STATE, 2021, 63 (07) : 998 - 1008