Management of pediatric radiation dose using GE's Revolution digital radiography systems

被引:2
|
作者
Jabri, KN [1 ]
Uppaluri, R [1 ]
Xue, P [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
关键词
digital radiography; pediatric radiography; pediatric dose; low-dose processing; image quality;
D O I
10.1007/s00247-004-1272-y
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Digital flat-panel x-ray detectors offer excellent image quality and dose efficiency in addition to clinical productivity, connectivity, and adaptability to advanced clinical applications. GE's Revolution systems provide two modes of exposure control for setting the dose operating point, fixed time and automatic exposure control, the latter of which maintains high image signal-to-noise ratio for the given technique settings. In addition to enhancing detail contrast and compressing the dynamic range, postprocessing automatically determines the best window level and width for display, taking into account the dose at which the image was acquired. Several studies have examined the reduction in patient dose achievable with Revolution systems as compared to competing technologies, and results indicate significant dose savings with equivalent or superior image quality. For pediatric exams, pediatric default techniques provide for a lower patient dose as compared to adult techniques. Therefore, GE's Revolution systems can achieve a high image quality-to-dose ratio for pediatric imaging using the combined advantages of dose-efficient detection, advanced postprocessing, and independently adjustable pediatric techniques.
引用
收藏
页码:S215 / S220
页数:6
相关论文
共 50 条
  • [41] Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice
    Veldkamp, WJH
    Kroft, LJM
    Boot, MV
    Mertens, BJA
    Geleijns, J
    EUROPEAN RADIOLOGY, 2006, 16 (02) : 333 - 341
  • [42] Development of Quality-Controlled Low-Dose Protocols for Radiography in the Neonatal ICU Using a New Mobile Digital Radiography System
    Choi, Gayoung
    Cheon, Jung-Eun
    Lee, Seunghyun
    Choi, Young Hun
    Shin, Seung Han
    Cho, Yeon Jin
    Park, Sun Won
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 488 - 493
  • [43] Optimization of dose and image quality in full-fiand computed radiography systems for common digital radiographic examinations
    Moey S.-F.
    Shazli Z.A.
    Moey, Soo-Foon (moeysf@iium.edu.my), 2018, Mashhad University of Medical Sciences (15) : 28 - 38
  • [44] Radiation Dose Reduction in Scoliosis Patients: Low-Dose Full-Spine Radiography with Digital Flat Panel Detector and Image Stitching System
    Grieser, T.
    Baldauf, A. Q.
    Ludwig, K.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2011, 183 (07): : 645 - 649
  • [45] Dose optimisation in paediatric radiography - Using regression models to investigate the relative impact of acquisition factors on image quality and radiation dose
    Ali, Ali Mohammed
    Hogg, Peter
    England, Andrew
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 68 : 61 - 68
  • [46] Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography
    Egbe N.O.
    Akintomide A.O.
    Inah G.B.
    Owolo E.
    Iranian Journal of Medical Physics, 2016, 13 (01) : 17 - 24
  • [48] Estimates of Patient Radiation Doses in Digital Radiography Using DICOM Information at a Large Teaching Hospital in Oman
    Ibrahim I. Suliman
    Journal of Digital Imaging, 2020, 33 : 64 - 70
  • [49] RADIATION-DOSE DURING HYSTEROSALPINGOGRAPHY USING A DIGITAL IMAGE INTENSIFICATION TECHNIQUE
    HAUSSLER, MD
    MERK, J
    TOMCZAK, R
    SCHNARKOWSKI, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (06): : 596 - 598
  • [50] Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems
    Sun, Zhonghua
    Lin, Chenghsun
    Tyan, YeuSheng
    Ng, Kwan-Hoong
    CLINICAL IMAGING, 2012, 36 (04) : 279 - 286