Management of pediatric radiation dose using GE's Revolution digital radiography systems

被引:2
|
作者
Jabri, KN [1 ]
Uppaluri, R [1 ]
Xue, P [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
关键词
digital radiography; pediatric radiography; pediatric dose; low-dose processing; image quality;
D O I
10.1007/s00247-004-1272-y
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Digital flat-panel x-ray detectors offer excellent image quality and dose efficiency in addition to clinical productivity, connectivity, and adaptability to advanced clinical applications. GE's Revolution systems provide two modes of exposure control for setting the dose operating point, fixed time and automatic exposure control, the latter of which maintains high image signal-to-noise ratio for the given technique settings. In addition to enhancing detail contrast and compressing the dynamic range, postprocessing automatically determines the best window level and width for display, taking into account the dose at which the image was acquired. Several studies have examined the reduction in patient dose achievable with Revolution systems as compared to competing technologies, and results indicate significant dose savings with equivalent or superior image quality. For pediatric exams, pediatric default techniques provide for a lower patient dose as compared to adult techniques. Therefore, GE's Revolution systems can achieve a high image quality-to-dose ratio for pediatric imaging using the combined advantages of dose-efficient detection, advanced postprocessing, and independently adjustable pediatric techniques.
引用
收藏
页码:S215 / S220
页数:6
相关论文
共 50 条
  • [1] Management of pediatric radiation dose using GE’s Revolution digital radiography systems
    K.N. Jabri
    R. Uppaluri
    P. Xue
    Pediatric Radiology, 2004, 34 : S215 - S220
  • [2] Management of pediatric radiation dose using Philips digital radiography
    U. Neitzel
    Pediatric Radiology, 2004, 34 : S227 - S233
  • [3] Management of pediatric radiation dose using Philips digital radiography
    Neitzel, U
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S227 - S233
  • [4] Management of pediatric radiation dose using Canon digital radiography
    M. Arreola
    L. Rill
    Pediatric Radiology, 2004, 34 : S221 - S226
  • [5] Management of pediatric radiation dose using Canon digital radiography
    Arreola, M
    Rill, L
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S221 - S226
  • [6] Digital radiography of scoliosis with a scanning method: radiation dose optimization
    Geijer, H
    Verdonck, B
    Beckman, KW
    Andersson, T
    Persliden, J
    EUROPEAN RADIOLOGY, 2003, 13 (03) : 543 - 551
  • [7] The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population
    Seibert, J. Anthony
    Morin, Richard L.
    PEDIATRIC RADIOLOGY, 2011, 41 (05) : 573 - 581
  • [8] The standardized exposure index for digital radiography: an opportunity for optimization of radiation dose to the pediatric population
    J. Anthony Seibert
    Richard L. Morin
    Pediatric Radiology, 2011, 41 : 573 - 581
  • [9] Radiation dose considerations in digital radiography with an anti-scatter grid: A study using adult and pediatric phantoms
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Kitao, Azusa
    Matsubara, Takashi
    Sugiura, Takumi
    Kobayashi, Tomohiro
    Kobayashi, Satoshi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):
  • [10] The practice of chest radiography using different digital imaging systems: Dose and image quality
    Moey S.-F.
    Shazli Z.A.
    Sayed I.S.
    Iranian Journal of Medical Physics, 2018, 15 (02) : 101 - 107