Prefabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: evaluation of peri-implant tissues and superstructures after 12 months of function

被引:33
作者
Nothdurft, Frank [1 ]
Pospiech, Peter [1 ]
机构
[1] Univ Saarland, Dept Prosthet Dent & Dent Mat Sci, D-6600 Saarbrucken, Germany
关键词
biomaterials; clinical research; clinical trials; soft tissue-implant interactions; FIXED PARTIAL DENTURES; CONTROLLED CLINICAL-TRIAL; ALL-CERAMIC RESTORATIONS; CUSTOMIZED ZIRCONIA; IN-VIVO; FRACTURE-RESISTANCE; MUCOSAL BARRIER; SOFT-TISSUES; FOLLOW-UP; TITANIUM;
D O I
10.1111/j.1600-0501.2009.01899.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim In the present study, prefabricated abutments made of zirconium dioxide Y-TZP (tetragonal zirconia polycrystals) were inserted into the posterior region under controlled clinical conditions. The aim was to test whether abutments made of zirconium dioxide are suitable for this indication. Investigation parameters included reactions of peri-implant tissue and the structural integrity of the all-ceramic superstructures on the implants. Results after 12 months in function are reported in this article. Material and methods Forty implants of the XiVE (R) S plus screw-type implants (DENTSPLY Friadent) were inserted into the posterior region of 24 patients. After the healing period, the implants were provided with all-ceramic abutments made of zirconium dioxide Y-TZP (FRIADENT (R) CERCON (R) Abutment; DENTSPLY Friadent). All-ceramic crowns (CERCON (R) smart ceramics; DENTSPLY DeguDent) were used as superstructures and cemented using the conventional method. The following parameters were used to document the state of soft tissue: modified plaque index (mPI), sulcus fluid flow rate (SFFR, Periotron; Oraflow Inc), modified sulcus bleeding index (mSBI) and pocket depth (ST). Mesial and distal bone levels were determined on radiographs during the prosthetic treatment and at the 12-month recall. The Periotest (TM) (Medizintechnik Gulden) was used to determine implant stability. Results All implants could be followed up after 12 months in function. In the presence of good oral hygiene (mPI: 0.5), the parameters SFFR (18) and mSBI (0.5) were indicative of stable and healthy soft tissue. ST was highest at the distal points of measurement (2.3 mm) and was generally at a low level. Compared with the baseline situation, proximal bone defects were reduced from -1.1 to -1 mm during the 12-month period of functioning. The mean Periost (TM) values at the 12-month recall were -1.9 in the maxilla and -3.8 in the mandible. Neither implant loss nor crown fractures occurred. Chipping of parts of the veneering ceramic was registered in four cases (10%). Conclusion After 12 months of wear, no mechanical failure was registered in any of the all-ceramic abutments. On clinical investigation, the peri-implant hard and soft tissues were largely healthy and devoid of inflammation. To cite this article:Nothdurft F, Pospiech P. Prefabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: evaluation of peri-implant tissues and superstructures after 12 months of function.Clin. Oral Impl. Res. 21, 2010; 857-865.doi: 10.1111/j.1600-0501.2009.01899.x.
引用
收藏
页码:857 / 865
页数:9
相关论文
共 48 条
[1]   The mucosal attachment at different abutments - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Glantz, PO ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1998, 25 (09) :721-727
[2]   The mucosal barrier following abutment dis/reconnection - An experimental study in dogs [J].
Abrahamsson, I ;
Berglundh, T ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (08) :568-572
[3]   Fracture Resistance of Yttria-Stabilized Zirconia Dental Implant Abutments [J].
Adatia, Nimet D. ;
Bayne, Stephen C. ;
Cooper, Lyndon F. ;
Thompson, Jeffery Y. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (01) :17-22
[4]  
Andersson B, 2003, INT J PROSTHODONT, V16, P640
[5]  
[Anonymous], COMPEND CONTIN EDUC
[6]  
Aramouni Philippe, 2008, J Contemp Dent Pract, V9, P41
[7]   Fracture resistance of single-tooth implant-supported all-ceramic restorations after exposure to the artificial mouth [J].
Att, W ;
Kurun, S ;
Gerds, T ;
Strub, JR .
JOURNAL OF ORAL REHABILITATION, 2006, 33 (05) :380-386
[8]  
Barboza Eliane P, 2002, Implant Dent, V11, P162, DOI 10.1097/00008505-200204000-00018
[9]   Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs) [J].
Beuer, Florian ;
Edelhoff, Daniel ;
Gernet, Wolfgang ;
Sorensen, John A. .
CLINICAL ORAL INVESTIGATIONS, 2009, 13 (04) :445-451
[10]   A 10-year prospective study of ITI dental implants placed in the posterior region. I: Clinical and radiographic results [J].
Blanes, Rafael Juan ;
Bernard, Jean Pierre ;
Blanes, Zulema Maria ;
Belser, Urs Christoph .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (06) :699-706