Left ventricular function during support with an asynchronous pulsatile left ventricular assist device

被引:14
|
作者
Dalby, MCD [1 ]
Banner, NR [1 ]
Tansley, P [1 ]
Grieve, LA [1 ]
Partridge, J [1 ]
Yacoub, MH [1 ]
机构
[1] Harefield Hosp, Royal Brompton & Harefield NHS Trust, Harefield UB9 6JH, Middx, England
来源
关键词
D O I
10.1016/S1053-2498(02)00566-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left ventricular assist devices (LVADs) are frequently used to maintain patients with severe heart failure until heart transplantation becomes possible. Some patients may experience recovery of LV function during such support. Therefore, it is essential to be able to monitor changes in LV function in this setting. Methods: We studied LV function in 10 patients (median age 34 years, 9 male) who had LVADs implanted because of severe heart failure due to dilated cardiomyopathy a median of 4 months previously. Median pre-implant ejection traction was 27% and all patients had been on maximal medical therapy, including intravenous inotropic support, prior to insertion of the LVAD. Results: During LVAD support there were cyclical variations in LV dimensions, fractional shortening (FS) and transmitral flow, related to changes in the phase relationship of the LV and the LVAD. The "best" FS occurred when LV systole coincided with device filling and the "worst" FS when LV systole coincided with device ejection. Median FS with the pump switched off was 18% (10% to 32%). Pump-off FS was significantly greater than the "worst" FS with the pump on (5%, p = 0.002), and similar to the "best" pump-on FS (19%, p = NS). Conclusions: LV function could be studied echocardiographically during LV support and brief periods of interruption in support. Function varied according to the phase relationship of the LV and LVAD. The "best" FS measured, during LVAD support was more closely related to the FS with the device switched off than the "worst" pump on FS. The "best" pump-on LV function is therefore most representative of intrinsic LV performance and can be used as a guide to recovery and the potential need for pump-off studies.
引用
收藏
页码:292 / 300
页数:9
相关论文
共 50 条
  • [41] Effect of clenbuterol on cardiac and skeletal muscle function during left ventricular assist device support
    George, Isaac
    Xydas, Steve
    Mancini, Donna M.
    Lamanca, John
    DiTullio, Marco
    Marboe, Charles C.
    Shane, Elizabeth
    Schulman, Allison R.
    Colley, Patrick M.
    Petrilli, Christopher M.
    Naka, Yoshifumi
    Oz, Mehmet C.
    Maybaum, Simon
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (09): : 1084 - 1090
  • [42] Global and regional right ventricular function with left ventricular assist device
    Sakaki, M
    Nikolic, SD
    CIRCULATION, 1996, 94 (08) : 1994 - 1994
  • [43] Validation of numerically simulated ventricular flow patterns during left ventricular assist device support
    Ghodrati, Mojgan
    Khienwad, Thananya
    Maurer, Alexander
    Moscato, Francesco
    Zonta, Francesco
    Schima, Heinrich
    Aigner, Philipp
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2021, 44 (01): : 30 - 38
  • [44] Tolerance of Sustained Ventricular Fibrillation During Left Ventricular Assist Device Support With IMPELLA CP®
    Caminiti, Rodolfo
    Colarusso, Luigi
    Vizzari, Giampiero
    Crea, Pasquale
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 40 : S305 - S307
  • [45] Pulmonary Bleeding During Right Ventricular Support After Left Ventricular Assist Device Implantation
    Welp, Henryk
    Sindermann, Juegen R.
    Deschka, Heinz
    Martens, Sven
    Scherer, Mirela
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (03) : 627 - 631
  • [46] Time course of reverse remodelling of the left ventricle during support with a left ventricular assist device
    Madigan, JD
    Barbone, A
    Choudhri, AF
    Morales, DLS
    Cai, B
    Oz, MC
    Burkhoff, D
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (05): : 902 - 908
  • [47] SYNCHRONIZED PULSATILE FLOW WITH A CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE
    Rutten, M. C. M.
    Tuzun, E.
    de Vosse, F. N. van
    de Mol, B. A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (07): : 449 - 449
  • [48] A DYNAMICAL MODEL FOR PULSATILE FLOW ESTIMATION IN A LEFT VENTRICULAR ASSIST DEVICE
    AlOmari, Abdul-Hakeem H.
    Savkin, Andrey V.
    Karantonis, Dean M.
    Lim, Einly
    Lovell, Nigel H.
    BIOSIGNALS 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING, 2009, : 402 - +
  • [49] Cognitive function and left ventricular assist device implantation
    Bhat, Geetha
    Yost, Gardner
    Mahoney, Edward
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (11): : 1398 - 1405
  • [50] Platelet function in patients with a left ventricular assist device
    Ashbrook, M.
    Schwatz, J.
    Heroux, A.
    Escalante, V
    Jeske, W.
    Walenga, J.
    Bakhos, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 344 - 344