Left ventricular function during support with an asynchronous pulsatile left ventricular assist device

被引:14
|
作者
Dalby, MCD [1 ]
Banner, NR [1 ]
Tansley, P [1 ]
Grieve, LA [1 ]
Partridge, J [1 ]
Yacoub, MH [1 ]
机构
[1] Harefield Hosp, Royal Brompton & Harefield NHS Trust, Harefield UB9 6JH, Middx, England
来源
关键词
D O I
10.1016/S1053-2498(02)00566-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left ventricular assist devices (LVADs) are frequently used to maintain patients with severe heart failure until heart transplantation becomes possible. Some patients may experience recovery of LV function during such support. Therefore, it is essential to be able to monitor changes in LV function in this setting. Methods: We studied LV function in 10 patients (median age 34 years, 9 male) who had LVADs implanted because of severe heart failure due to dilated cardiomyopathy a median of 4 months previously. Median pre-implant ejection traction was 27% and all patients had been on maximal medical therapy, including intravenous inotropic support, prior to insertion of the LVAD. Results: During LVAD support there were cyclical variations in LV dimensions, fractional shortening (FS) and transmitral flow, related to changes in the phase relationship of the LV and the LVAD. The "best" FS occurred when LV systole coincided with device filling and the "worst" FS when LV systole coincided with device ejection. Median FS with the pump switched off was 18% (10% to 32%). Pump-off FS was significantly greater than the "worst" FS with the pump on (5%, p = 0.002), and similar to the "best" pump-on FS (19%, p = NS). Conclusions: LV function could be studied echocardiographically during LV support and brief periods of interruption in support. Function varied according to the phase relationship of the LV and LVAD. The "best" FS measured, during LVAD support was more closely related to the FS with the device switched off than the "worst" pump on FS. The "best" pump-on LV function is therefore most representative of intrinsic LV performance and can be used as a guide to recovery and the potential need for pump-off studies.
引用
收藏
页码:292 / 300
页数:9
相关论文
共 50 条
  • [1] Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support
    Klotz, S
    Deng, MC
    Stypmann, J
    Roetker, J
    Wilhelm, MJ
    Hammel, D
    Scheld, HH
    Schmid, C
    ANNALS OF THORACIC SURGERY, 2004, 77 (01): : 143 - 149
  • [2] Ventricular arrhythmias during left ventricular assist device support
    Bedi, Maninder
    Kormos, Robert
    Winowich, Steve
    McNamara, Dennis M.
    Mathier, Michael A.
    Murali, Srinivas
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 1151 - 1153
  • [3] Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support - Invited commentary
    Lachapelle, K
    ANNALS OF THORACIC SURGERY, 2004, 77 (01): : 149 - 150
  • [4] Optimal Timing for Echocardiographic Assessment of Left Ventricular Function During Reduced Left Ventricular Assist Device Support
    Salahuddin, Ayesha
    Fujikura, Kana
    Birks, Emma J.
    Cunningham, Chris
    Kallel, Faouzi
    Spevack, Daniel M.
    Garcia, Mario J.
    CIRCULATION, 2015, 132
  • [5] Hemodynamic response during non-pulsatile vs pulsatile left ventricular assist device support
    Klotz, S
    Schmid, C
    Scheld, HH
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (12): : 2306 - 2307
  • [6] Measurement of Left Ventricular Chamber Function in the Setting of Ventricular Assist Device Support
    Gupta, S.
    Muthiah, K.
    Woldendorp, K.
    Robson, D.
    Jansz, P.
    Hayward, C. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S55 - S55
  • [7] Platelet Function and Sildenafil Use During Left Ventricular Assist Device Support
    Saeed, O.
    Farooq, M.
    Chinnadurai, T.
    Ramos, J.
    Patel, S.
    Chavez, P.
    Rochlani, Y.
    Murthy, S.
    Shin, J.
    Vukelic, S.
    Sims, D.
    Goldstein, D.
    Jorde, U.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2023, 42 (04): : S70 - S70
  • [8] Renal Function Recover With Left Ventricular Assist Device Support
    Goodreau, A.
    Kasirajan, V.
    Wolfe, L. G.
    Feldman, G.
    Quader, M. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S220 - S220
  • [9] Modelling left ventricular function under assist device support
    McCormick, M.
    Nordsletten, D.
    Kay, D.
    Smith, N.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2011, 27 (07) : 1073 - 1095
  • [10] Neurohormonal Blockade During Left Ventricular Assist Device Support
    Imamura, Teruhiko
    Mehta, Priya
    Nguyen, Ann
    Chung, Ben
    Narang, Nikhil
    Rodgers, Daniel
    Raikhelkar, Jayant
    Smith, Bryan
    Song, Tae
    Ota, Takeyoshi
    Jeevanandam, Valluvan
    Kim, Gene
    Sayer, Gabriel
    Uriel, Nir
    ASAIO JOURNAL, 2020, 66 (08) : 881 - 885