Left ventricular function during support with an asynchronous pulsatile left ventricular assist device

被引:14
作者
Dalby, MCD [1 ]
Banner, NR [1 ]
Tansley, P [1 ]
Grieve, LA [1 ]
Partridge, J [1 ]
Yacoub, MH [1 ]
机构
[1] Harefield Hosp, Royal Brompton & Harefield NHS Trust, Harefield UB9 6JH, Middx, England
关键词
D O I
10.1016/S1053-2498(02)00566-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Left ventricular assist devices (LVADs) are frequently used to maintain patients with severe heart failure until heart transplantation becomes possible. Some patients may experience recovery of LV function during such support. Therefore, it is essential to be able to monitor changes in LV function in this setting. Methods: We studied LV function in 10 patients (median age 34 years, 9 male) who had LVADs implanted because of severe heart failure due to dilated cardiomyopathy a median of 4 months previously. Median pre-implant ejection traction was 27% and all patients had been on maximal medical therapy, including intravenous inotropic support, prior to insertion of the LVAD. Results: During LVAD support there were cyclical variations in LV dimensions, fractional shortening (FS) and transmitral flow, related to changes in the phase relationship of the LV and the LVAD. The "best" FS occurred when LV systole coincided with device filling and the "worst" FS when LV systole coincided with device ejection. Median FS with the pump switched off was 18% (10% to 32%). Pump-off FS was significantly greater than the "worst" FS with the pump on (5%, p = 0.002), and similar to the "best" pump-on FS (19%, p = NS). Conclusions: LV function could be studied echocardiographically during LV support and brief periods of interruption in support. Function varied according to the phase relationship of the LV and LVAD. The "best" FS measured, during LVAD support was more closely related to the FS with the device switched off than the "worst" pump on FS. The "best" pump-on LV function is therefore most representative of intrinsic LV performance and can be used as a guide to recovery and the potential need for pump-off studies.
引用
收藏
页码:292 / 300
页数:9
相关论文
共 13 条
[1]   Implantable left ventricular assist devices provide an excellent outpatient bridge to transplantation and recovery [J].
DeRose, JJ ;
Umana, JP ;
Argenziano, M ;
Catanese, KA ;
Gardocki, MT ;
Flannery, M ;
Levin, HR ;
Sun, BC ;
Rose, EA ;
Oz, MC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (07) :1773-1777
[2]   Improved left ventricular function after chronic left ventricular unloading [J].
Frazier, OH ;
Benedict, CR ;
Radovancevic, B ;
Bick, RJ ;
Capek, P ;
Springer, WE ;
Macris, MP ;
Delgado, R ;
Buja, LM .
ANNALS OF THORACIC SURGERY, 1996, 62 (03) :675-681
[3]  
FRAZIER OH, 1993, CARDIAC SURG STATE A, V7, P353
[4]   The Registry of the International Society for Heart and Lung Transplantation: Seventeenth official report - 2000 [J].
Hosenpud, JD ;
Bennett, LE ;
Keck, BM ;
Boucek, MM ;
Novick, RJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2000, 19 (10) :909-931
[5]   HeartMate left ventricular assist device as bridge to heart transplantation [J].
Koul, B ;
Solem, JO ;
Steen, S ;
Casimir-Ahn, H ;
Granfeldt, H ;
Lönn, UJ .
ANNALS OF THORACIC SURGERY, 1998, 65 (06) :1625-1630
[6]   Long-term mechanical circulatory support as a bridge to transplantation, for recovery from cardiomyopathy, and for permanent replacement [J].
Loebe, M ;
Hennig, E ;
Muller, J ;
Spiegelsberger, S ;
Weng, Y ;
Hetzer, R .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 :S18-S24
[7]   Low incidence of myocardial recovery after left ventricular assist device implantation in patients with chronic heart failure [J].
Mancini, DM ;
Beniaminovitz, A ;
Levin, H ;
Catanese, K ;
Flannery, M ;
DiTullio, M ;
Savin, S ;
Cordisco, ME ;
Rose, E ;
Oz, M .
CIRCULATION, 1998, 98 (22) :2383-2389
[8]  
MANDARINO WA, 1995, ASAIO J, V41, pM544, DOI 10.1097/00002480-199507000-00070
[9]   Epidemiology, aetiology, and prognosis of heart failure [J].
McMurray, JJ ;
Stewart, S .
HEART, 2000, 83 (05) :596-602
[10]   Left ventricular diastolic filling with an implantable ventricular assist device: Beat to beat variability with overall improvement [J].
Nakatani, S ;
Thomas, JD ;
Vandervoort, PM ;
Zhou, JH ;
Greenberg, NL ;
Savage, RM ;
McCarthy, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (05) :1288-1294