Numerical analysis of different valve effects on the cooling performance of a two-stage GM type pulse tube cryocooler

被引:11
|
作者
Kim, Kwangson [1 ]
Zhi, Xiaoqin [1 ]
Qiu, Limin [1 ]
Nie, Huailong [1 ]
Wang, Jianjun [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310027, Zhejiang, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2017年 / 77卷
基金
中国国家自然科学基金;
关键词
GM type PTC; Liquid helium temperatures; Valve setting; Phase shifting; COOLERS;
D O I
10.1016/j.ijrefrig.2017.02.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
The cooling performance of GM type pulse tube cryocoolers (PTCs) is strongly affected by the valve setting for phase shifting. In this research, the effects of different valve openings on the no-load temperatures in a two-stage GM PTC have been investigated by numerical simulation. Results show that the no-load temperature at the 1st stage mainly depends on the openings of 1st stage orifice valve, and both 1st and 2nd stage double-inlet valves. While the no-load temperature at the 2nd stage below 10 K sensitively depends on the openings of both 1st and 2nd stage orifice valves, and 2nd stage double-inlet valves. There exist several local minimum no-load temperatures at the 2nd stage under different valve openings below 7 K. The best valve setting corresponds to minimizing the cold end phase angle, making the cold end acoustic power compensate the real gas enthalpy flow with maximum degree. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] Numerical investigation of real gas effects on a two-stage pulse tube cryocooler performance
    Rezaei, M.
    Jafarian, A.
    Kardgar, A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 106 - 118
  • [2] Performance of a two-stage pulse tube cryocooler for space applications
    Olson, JR
    Kotsubo, V
    Champagne, PJ
    Nast, TC
    CRYOCOOLERS 10, 1999, : 163 - 170
  • [3] A two-stage Stirling-type pulse tube cryocooler with a cold inertance tube
    Gan, Z. H.
    Fan, B. Y.
    Wu, Y. Z.
    Qiu, L. M.
    Zhang, X. J.
    Chen, G. B.
    CRYOGENICS, 2010, 50 (6-7) : 426 - 431
  • [4] Design model for a two-stage pulse tube cryocooler
    Shi, J. L.
    Pfotenhauer, J. M.
    Nellis, G. F.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 329 - +
  • [5] Numerical investigation on non-linear streaming effects in a two-stage coaxial pulse tube cryocooler
    Damu, C.
    Moudghalya, Sumukh
    Nerale, Mrunal M.
    Panda, Debashis
    Prasad, Rajendra K. S.
    Behera, Upendra
    Reddy, B. N. Sathyanarantana
    PHYSICS OF FLUIDS, 2024, 36 (01)
  • [6] Cooling performance improvement of a two-stage pulse tube cryocooler with Er-plated screen as regenerator material
    Wu, Wenting
    Cui, Xiaoyu
    Liu, Shaoshuai
    Jiang, Zhenhua
    Song, Jiantang
    Wu, Yinong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 615 - 622
  • [7] INVESTIGATION ON TWO-STAGE 300 HZ PULSE TUBE CRYOCOOLER
    Cai, H. K.
    Yang, L. W.
    Hong, G. T.
    Luo, E. C.
    Zhou, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 60 - 67
  • [8] Lockheed Martin two-stage pulse tube cryocooler for GIFTS
    Nast, T
    Frank, D
    Roth, E
    Champagne, P
    Olson, J
    Evtimov, B
    Clappier, R
    Renna, T
    Martin, B
    Cryocoolers 13, 2005, : 121 - 126
  • [9] Transient analysis of single stage GM type double inlet pulse tube cryocooler
    Gujarati, P. B.
    Desai, K. P.
    Naik, H. B.
    Atrey, M. D.
    ADVANCES IN CRYOGENIC ENGINEERING, 2015, 101
  • [10] 15 K two-stage Stirling-type pulse-tube cryocooler
    Yan, Pengda
    Chen, Guobang
    Dong, Jingjing
    Gao, Weili
    CRYOGENICS, 2009, 49 (02) : 103 - 106