Bearing Capacity of Strengthened Reinforced Concrete Beams

被引:0
|
作者
Kinasz, Roman [1 ]
Mazurak, Andrii [2 ]
Kovalyk, Ivan [2 ]
Mazurak, Rostyslav [2 ]
Tsap, Orest [2 ]
机构
[1] AGH Univ Sci & Technol, Fac Min & Geoengn, Al Mickiewicza 30, PL-30059 Krakow, Poland
[2] Lviv Natl Agr Univ, Dept Bldg Struct, V Velikogo 1, UA-80381 Dublyany, Ukraine
关键词
D O I
10.1088/1757-899X/960/2/022047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The need reinforcement building structures during operation arises not only during reconstruction but also because various damages. The various combination reasons for the need reinforcement, as well as the type and condition the building structures necessitates the use different ways reinforcement. Today, it is still effective to reinforce the bending elements of reinforced concrete structures with reinforced concrete and shotcrete. Therefore, the purpose of our work is to improve the calculation method, to evaluate the load-bearing capacity reinforced concrete beams, taking into account residual deformations and stresses of concrete and reinforcement. Methods for reinforcing reinforced concrete structures are described in detail in literature and are widely used in construction. The proposed experimental studies consisted 15 reinforced concrete beams with design dimensions 2300x200x80 (120; 145). Nine beams were reinforced with reinforced concrete, five beams reinforced with concrete and one beam without reinforcement. The test specimens were amplified by the extension of the lateral surfaces at different loading levels, namely 0.0; 0.3; 0.45; 0.6 from the devastating moment. To create such levels of load, a specially designed metal rig was used, transmitting its effect to the test beam in the form of two concentrated forces in thirds of the span. Before the reinforcement of the contact beams of the test beams, adhesive layers were applied, metal anchors were affixed to which the reinforcement frames were fastened. The bearing capacity of the normal cross sections of the experimental, reinforced concrete beams was evaluated according to the proposed algorithm, based on the deformation model. The algorithm is adapted to calculate reinforced concrete beam structures in various ways (extension, shirt or clip). In the calculation method, the joint work of the layers of "old" and "new" concrete was taken into account by assigning all elements of the section a single bend. Adopted structural and technological solutions in the test beams, namely the use of shotcrete concrete, adhesive priming, and glued metal anchors ((empty set) 8mm) protruding from the surface at 35mm, ensured the matrix and reinforcement layers work together. Based on the experimental studies, the analysis of the calculated data with the experimental results was performed. The proposed calculation method well estimates the bearing capacity of the normal cross sections reinforced with reinforced shotcrete concrete reinforced concrete beams, the difference reaches no more than 6%. However, as the analysis of the results of the studies in the cross sections of the test pieces of the main and reinforced part of the beam shows, the experimental and calculated values of concrete deformations have a greater divergence, similarly this phenomenon is observed in the results of deformation of reinforcement. The discrepancy between the calculated and experimental values of the main and reinforced part of the beam is revealed due to the delayed inclusion in the work of reinforcement of the reinforced part, which should be taken into account in the following studies.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Bending Capacity of Reinforced Concrete Slabs Strengthened with Textile Reinforced Concrete
    Schladitz, Frank
    Lorenz, Enrico
    Curbach, Manfred
    BETON- UND STAHLBETONBAU, 2011, 106 (06) : 379 - 386
  • [42] Predicting the Optimum Shear Capacity of Reinforced Concrete Beams Externally Strengthened With CFRP Composites
    Al-Rousan, Rajai
    1ST INTERNATIONAL CONFERENCE ON OPTIMIZATION-DRIVEN ARCHITECTURAL DESIGN (OPTARCH 2019), 2020, 44 : 631 - 638
  • [43] Moment Capacity and Ductility of Reinforced Concrete Beams Strengthened with Ferrocement Including Steel Bars
    Xiong, Guangjing
    Ye, Surong
    Zhu, Zhanxian
    ADVANCED SCIENCE LETTERS, 2011, 4 (8-10) : 3249 - 3255
  • [44] Influence of adhesive thickness on the flexural capacity of reinforced concrete beams strengthened with CFRP sheets
    Huang, Junhao
    Qian, Yongjiu
    Yang, Huaping
    Hua, Wenwen
    Li, Jing
    Journal of Railway Science and Engineering, 2022, 19 (03) : 743 - 751
  • [45] Calculation of Flexural Capacity of High-strength Reinforced Concrete Beams Strengthened with FRP
    Liang, Jiong-Feng
    Yang, Ze-Ping
    Qiu, Zhi-Ming
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 815 - 817
  • [46] Shear capacity of reinforced concrete beams strengthened with web side bonded CFRP sheets
    Thamrin, Rendy
    Zaidir
    Haris, Sabril
    INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS (SCESCM 2018), 2019, 258
  • [47] Flexural capacity of continuous reinforced concrete beams strengthened or repaired by CFRP/GFRP sheets
    Ali, Harith
    Assih, Jules
    Li, Ales
    INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2021, 104
  • [48] Capacity Calculation on Reinforced Concrete Beams Strengthened by Externally Prestressed Transverse Tensioning Method
    Tong, Youzhi
    Wang, Tianwen
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 636 - 641
  • [49] Flexural capacity design model of reinforced concrete beams strengthened with hybrid bonded CFRP
    Zhang, Ying
    Zhang, Feng
    Wu, Lan
    Han, Hao-Zhe
    Wu, Yu-Fei
    ENGINEERING STRUCTURES, 2024, 319
  • [50] Analysis of reinforced concrete beams strengthened using concrete jackets
    Alhadid, M. Monir A.
    Youssef, Maged A.
    ENGINEERING STRUCTURES, 2017, 132 : 172 - 187