Use of Supplemental Short Pre-Contoured Accessory Rods and Cobalt Chrome Alloy Posterior Rods Reduces Primary Rod Strain and Range of Motion Across the Pedicle Subtraction Osteotomy Level An In Vitro Biomechanical Study

被引:69
作者
Hallager, Dennis Winge [1 ]
Gehrchen, Martin [1 ]
Dahl, Benny [1 ]
Harris, Jonathan A. [2 ]
Gudipally, Manasa [2 ]
Jenkins, Sean [2 ]
Wu, Ai-Min [3 ]
Bucklen, Brandon S. [2 ]
机构
[1] Copenhagen Univ Hosp, Dept Orthopaed Surg, Copenhagen, Denmark
[2] A Div Globus Med Inc, Musculoskeletal Educ & Res Ctr, Audubon, PA USA
[3] Wenzhou Med Univ, Dept Spinal Surg, Affiliated Hosp 2, Wenzhou, Peoples R China
关键词
4-rod; accessory rods; anterior column support; cadaveric biomechanics; lumbar lateral interbody fusion; multi-rod; pedicle subtraction osteotomy; revision surgery; rod breakage; surface rod strain; ADULT SPINAL DEFORMITY; 4-ROD TECHNIQUE; LUMBOPELVIC RECONSTRUCTION; LUMBOSACRAL FIXATION; SAGITTAL IMBALANCE; RISK-FACTORS; SURGERY; FUSION; COMPLICATIONS; SCOLIOSIS;
D O I
10.1097/BRS.0000000000001282
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vitro cadaveric biomechanical study. Objective. To assess effects of 4-rod reconstruction, rod material, and anterior column support on motion and surface rod strain in a pedicle subtraction osteotomy model. Summary of Background Data. Pedicle subtraction osteotomy (PSO) can correct significant sagittal deformity of the lumbar spine; however, revision rates are high. To reduce rod strain and the incidence of rod fracture, clinical use of multi-rod construction, cobalt chrome (CoCr) alloy rods, and interbody spacers adjacent to PSO has been proposed. Investigating both motion and rod strain is necessary to determine the biomechanical efficacy of these techniques. Methods. Five specimens (T12-S1) underwent PSO at L3 with pedicle screw stabilization at L1-S1. Pedicle subtraction was adjusted to achieve a final lordosis of 70-degrees. Flexion-extension (FE), lateral bending, and axial rotation were applied. Linear strain gauges measured surface rod strain during FE on primary and accessory rods at PSO level. Testing evaluated (1) accessory rods (4-Rod) added at PSO level versus primary rods (2-Rod); (2) Ti versus CoCr rods; and (3) lateral interbody spacers (S) inserted adjacent to PSO. One-way and three-way analysis of variance was performed (P <= 0.05). Results. All constructs significantly reduced FE and lateral bending motion relative to intact (P < 0.001). The main effect of accessory rods in reducing FE motion was significant (P = 0.021). Accessory and CoCr rods reduced relative surface strain on the primary rod, irrespective of construct (P < 0.001). CoCr 4-Rod vertical bar S provided the greatest reduction in strain (76% decrease; P = 0.003). Conclusion. Accessory and CoCr rods provided greatest reduction in motion and rod strain at PSO level. Interbody devices minimally affected motion-induced strain and might act primarily to maintain disc height. Clinicians must assess whether surface strain and motion reduction minimize the incidence of rod fracture.
引用
收藏
页码:E388 / E395
页数:8
相关论文
共 34 条
  • [1] BARREY C, 2014, EUR J ORTHOP SURG S1, V24, pS21, DOI [10.1007/s00590-014-1470-8, DOI 10.1007/S00590-014-1470-8]
  • [2] Bergin PF, 2010, ORTHOPEDICS, V33, P586, DOI [10.3928/01477447-20100625-22, 10.3928/01477447-20100801-02]
  • [3] Complications and Risk Factors of Primary Adult Scoliosis Surgery A Multicenter Study of 306 Patients
    Charosky, Sebastien
    Guigui, Pierre
    Blamoutier, Arnaud
    Roussouly, Pierre
    Chopin, Daniel
    [J]. SPINE, 2012, 37 (08) : 693 - 700
  • [4] Pedicle Subtraction Osteotomy in Elderly Patients With Degenerative Sagittal Imbalance
    Cho, Kyu-Jung
    Kim, Ki-Tack
    Kim, Whoan-Jeang
    Lee, Sang-Hoon
    Jung, Jae-Hoon
    Kim, Young-Tae
    Park, Hae-Bong
    [J]. SPINE, 2013, 38 (24) : E1561 - E1566
  • [5] Cho SK, 2012, SPINE, V37, P489
  • [6] Adult spinal deformity surgery - Complications and outcomes in patients over age 60
    Daubs, Michael D.
    Lenke, Lawrence G.
    Cheh, Gene
    Stobbs, Georgia
    Bridwell, Keith H.
    [J]. SPINE, 2007, 32 (20) : 2238 - 2244
  • [7] Davis C. S., 2002, STAT METHODS ANAL RE
  • [8] Construct Rigidity after Fatigue Loading in Pedicle Subtraction Osteotomy with or without Adjacent Interbody Structural Cages
    Deviren, Vedat
    Tang, Jessica A.
    Scheer, Justin K.
    Buckley, Jenni M.
    Pekmezci, Murat
    McClellan, R. Trigg
    Ames, Christopher P.
    [J]. GLOBAL SPINE JOURNAL, 2012, 2 (04) : 213 - 220
  • [9] Notch sensitivity of titanium alloy, commercially pure titanium, and stainless steel spinal implants
    Dick, JC
    Bourgeault, CA
    [J]. SPINE, 2001, 26 (15) : 1668 - 1672
  • [10] Test protocols for evaluation of spinal implants
    Goel, VK
    Panjabi, MM
    Patwardhan, AG
    Dooris, AP
    Serhan, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A : 103 - 109