The new V12 ultra-small-angle neutron scattering and tomography instrument at the Hahn-Meitner Institut

被引:25
作者
Strobl, M.
Treimer, W.
Ritzoulis, C.
Wagh, A. G.
Abbas, S.
Manke, I.
机构
[1] Univ Appl Sci TFH Berlin, D-13353 Berlin, Germany
[2] Hahn Meitner Inst Berlin GmbH, D-14109 Berlin, Germany
[3] Univ Thessaloniki, Dept Chem Engn, GR-54006 Thessaloniki, Greece
[4] Bhabha Atom Res Ctr, Div Solid State Phys, Bombay 400085, Maharashtra, India
关键词
D O I
10.1107/S0021889806050813
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The new V12 instrument at the Hahn-Meitner Institute in Berlin is a multiple setup combining several techniques to investigate the internal structure of bulk samples. It consists of two double-crystal diffractometers (DCDs) and an attenuation tomography device operating with monochromatic neutrons. The three instrument parts can be used independently at the same time. The DCDs are mainly used in the ultra-small-angle neutron scattering (USANS) regime, where they overlap the accessible range of small-angle neutron scattering instruments, while tomographic methods collect real-space information on a macroscopic scale. Together they enable structural investigations over six orders of magnitude (50 nm to 5 cm). Scattering and tomographic methods can even be combined by means of diffraction and scattering-enhanced imaging. The sample environment can be varied over a large range of temperatures and pressures for USANS measurements and a polarized USANS option is available.
引用
收藏
页码:S463 / S465
页数:3
相关论文
共 24 条
[11]   Ultra-small-angle neutron scattering: a new tool for materials research [J].
Schaefer, DW ;
Agamalian, MM .
CURRENT OPINION IN SOLID STATE & MATERIALS SCIENCE, 2004, 8 (01) :39-47
[12]   3D neutron computed tomography: requirements and applications [J].
Schillinger, B ;
Lehmann, E ;
Vontobel, P .
PHYSICA B-CONDENSED MATTER, 2000, 276 (276) :59-62
[13]   First realisation of a three-dimensional refraction contrast computerised neutron tomography [J].
Strobl, M ;
Treimer, W ;
Hilger, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 222 (3-4) :653-658
[14]   Small angle scattering signals for (neutron) computerized tomography [J].
Strobl, M ;
Treimer, W ;
Hilger, A .
APPLIED PHYSICS LETTERS, 2004, 85 (03) :488-490
[15]  
STROBL M, THESIS TU VIENNA AUS, P3
[16]   Scattering-related contrast signals in neutron computerized tomography and the new V12 instrument at HMI Berlin [J].
Strobl, Markus ;
Treimer, Wolfgang ;
Hilger, Andre .
PHYSICA B-CONDENSED MATTER, 2006, 385-86 :1209-1212
[17]   Processing and properties of hydroxyapatite-based biomaterials for use as hard tissue replacement implants [J].
Suchanek, W ;
Yoshimura, M .
JOURNAL OF MATERIALS RESEARCH, 1998, 13 (01) :94-117
[18]   Thermal neutron optical experiments with tuneable many-bounce channel-cut crystals [J].
Treimer, W ;
Strobl, M ;
Hilger, A .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1) :S191-S193
[19]   Refraction as imaging signal for computerized (neutron) tomography [J].
Treimer, W ;
Strobl, M ;
Hilger, A ;
Seifert, C ;
Feye-Treimer, U .
APPLIED PHYSICS LETTERS, 2003, 83 (02) :398-400
[20]   Development of a tuneable channel cut crystal [J].
Treimer, W ;
Strobl, M ;
Hilger, A .
PHYSICS LETTERS A, 2001, 289 (03) :151-154