External quality assessment (EQA) for CoaguChek monitors

被引:25
作者
Jespersen, Joergen [2 ,3 ]
Poller, Leon [1 ]
van den Besselaar, A. M. H. P.
van der Meer, Felix J. M. [4 ]
Palareti, Gualtiero [5 ]
Tripodi, Armando [6 ]
Shiach, Caroline [7 ]
Keown, Michelle [1 ]
Ibrahim, Saied [1 ]
机构
[1] Univ Manchester, Fac Life Sci, EAA Cent Facil, Manchester M13 9PT, Lancs, England
[2] Univ So Denmark, Inst Publ Hlth, Dept Thrombosis Res, Esbjerg, Denmark
[3] Hosp SW Denmark, Dept Clin Biochem, Esbjerg, Denmark
[4] Leiden Univ, Med Ctr, Dept Thrombosis & Haemostasis, Thrombosis Serv Leiden, Leiden, Netherlands
[5] Univ Hosp St Orsola Malpighi, Dept Angiol & Blood Coagulat, Bologna, Italy
[6] Univ & IRCCS Maggiore Hosp, Mangiagalli & Regina Elena Fdn, Milan, Italy
[7] Manchester Royal Infirm, Dept Haematol, Manchester M13 9WL, Lancs, England
关键词
Oral anticoagultaion; external quality assessment; point-of-care monitors; INR deviation; accuracy; precision; EUROPEAN CONCERTED ACTION; INTERNATIONAL NORMALIZED RATIOS; PROTHROMBIN TIME MONITORS; POINT; ANTICOAGULATION; CALIBRATION; PRECISION; THERAPY; SYSTEM; MINI;
D O I
10.1160/TH09-10-0683
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Anticoagulant control facilities are being overwhelmed by requests for monitoring and large numbers of patients are not therefore receiving treatment. Procedures designed for point-of-care testing have therefore been developed, the most popular being the CoaguChek.The need for external quality assessment (EQA) of monitors used by patients in self-management has been stressed in a European Commission (EC) Directive. It would not however be feasible for all CoaguChek monitors to be enrolled in national or regional EQA schemes which take time to organise and analyse. The European Concerted Action on Anticoagulation (ECAA) has therefore evolved a simpler system. Its value has been assessed in collaboration with the European Concerted Action on Thrombosis (ECAT). 523 monitors were tested at nine clinics which asked patients to bring their CoaguChek instruments to be assessed with the ECAA/ECAT procedure based on a set of 5 plasma samples with certified international normalised ratios (INR). 15% or more deviation from the certified INR on a single certified plasma sample from the set was defined by the ECAA as the limit of acceptable performance. One hundred and six (20.3%) of the monitors tested showed significant deviation and higher than average incidence of significant INR deviations reported with one specific numbered lot of test strips. Recent ECAA/ECAT, Danish and Italian studies report regular EQA of CoaguChek monitors is essential. There is general agreement that this should be performed at reasonably frequent intervals, at six months or whenever there is a change of the manufacturer's test strips.
引用
收藏
页码:936 / 941
页数:6
相关论文
共 22 条
[1]   The pharmacology and management of the vitamin K antagonists [J].
Ansell, J ;
Hirsh, J ;
Poller, L ;
Bussey, H ;
Jacobson, A ;
Hylek, E .
CHEST, 2004, 126 (03) :204S-233S
[2]   Point-of-care (POCT) prothrombin time monitors: is a periodical control of their performance useful? [J].
Barcellona, Doris ;
Fenu, Lara ;
Cornacchini, Simona ;
Marongiu, Francesco .
THROMBOSIS RESEARCH, 2009, 123 (05) :775-779
[3]   Performance evaluation of the new CoaguChek XS system compared with the established CoaguChek system by patients experienced in INR-self management [J].
Braun, Siegmund ;
Watzke, Herbert ;
Hasenkam, J. Michael ;
Schwab, Michael ;
Wolf, Tanja ;
Dovifat, Clemens ;
Voeller, Heinz .
THROMBOSIS AND HAEMOSTASIS, 2007, 97 (02) :310-314
[4]  
Cai ZJ, 1999, WHO TECH REP SER, V887, P1
[5]   OPTIMAL ORAL ANTICOAGULANT-THERAPY IN PATIENTS WITH MECHANICAL HEART-VALVES [J].
CANNEGIETER, SC ;
ROSENDAAL, FR ;
WINTZEN, AR ;
VANDERMEER, FJM ;
VANDENBROUCKE, JP ;
BRIET, E .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (01) :11-17
[6]   International normalised ratio (INR) measured on the CoaguChek S and XS compared with the laboratory for determination of precision and accuracy [J].
Christensen, Thomas D. ;
Larsen, Torben B. ;
Jensen, Claus ;
Maegaard, Marianne ;
Sorensen, Benny .
THROMBOSIS AND HAEMOSTASIS, 2009, 101 (03) :563-569
[7]  
Connock M, 2007, HEALTH TECHNOL ASSES, V11, P1
[8]  
*ISO IEC, 431 ISOIEC
[9]   Point-of-care International Normalised Ratios: UKNEQAS experience demonstrates necessity for proficiency testing of three different monitors [J].
Kitchen, Stephen ;
Kitchen, Dianne P. ;
Jennings, Ian ;
Woods, Tim A. L. ;
Walker, Isobel D. ;
Preston, F. Eric .
THROMBOSIS AND HAEMOSTASIS, 2006, 96 (05) :590-596
[10]   Multicentre ISI assignment and calibration of the INR measuring range of a new point-of-care system designed for home monitoring of oral anticoagulation therapy [J].
Leichsenring, Ingrid ;
Plesch, Winfried ;
Unkrig, Volker ;
Kitchen, Steve ;
Kitchen, Dianne P. ;
Maclean, Rhona ;
Dikkeschei, Bert ;
van den Besselaar, Anton M. H. P. .
THROMBOSIS AND HAEMOSTASIS, 2007, 97 (05) :856-861