摘要
Most battery charge controllers in stand-alone photovoltaic power systems shed portions of the PV array in discrete steps as the battery voltage approaches full charge. This paper analyzes the effect of such on/off algorithms on the system performance. A simple analytical model of a multi-step charge controller is presented and illustrated by an example. Computer simulations and field measurements of an actual system show that on/off chargers limit the use of PV energy hence resulting in lower performance than conventional models.
引用
收藏
页码:1497 / 1501
页数:5
相关论文
共 6 条
[1]  
HAMMOND RL, 1997, 26 IEEE PVSC AN CA S
[2]  
HUND TD, 1997, 26 IEEE PVSC AN CA S
[3]  
MENICUCCI D, 1988, SAND850376
[4]  
STEVENSON JW, STUDY LEAD ACID BATT
[5]  
WHITEHEAD ML, 1994, P 8 BATT C EXH SOL U
[6]  
WOODWORTH JR, 1 WORLD C PHOT EN CO