Review of Research on the Fire Behavior of Simple Shear Connections

被引:12
|
作者
Fischer, Erica C. [1 ]
Chicchi, Rachel [2 ]
Choe, Lisa [3 ]
机构
[1] Oregon State Univ, Corvallis, OR 97331 USA
[2] Univ Cincinnati, Cincinnati, OH USA
[3] NIST, Gaithersburg, MD 20899 USA
关键词
Standard fire; Testing; Steel structures; Connections; FIN PLATE CONNECTIONS; COMPOSITE BEAMS; STEEL JOINT; TESTS;
D O I
10.1007/s10694-021-01105-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Previous building fires and research has shown that simple (shear) connections develop large axial force and flexural demands during a fire leading to potential failure of the connections and progressive collapse of a building. These findings have motivated decades of international research on the fire behavior of simple (shear) connections. While this research all confirmed that simple connections experience large axial force and flexural demands, it occurred without consistency of testing methodology, testing setup, and reporting of results. Due to this inconsistency, the decades of research have yet to be synthesized into comprehensive code changes for the design of simple connections in fires. This paper will summarize international experimental and numerical research on simple (shear) connections and highlight the inconsistencies between this research in an effort to motivate consistent testing and data reporting for future research developments.
引用
收藏
页码:1519 / 1540
页数:22
相关论文
共 50 条
  • [21] Fire Resistance and Post-fire Seismic Behavior of High Strength Concrete Shear Walls
    Xiao, Jianzhuang
    Xie, Qinghai
    Li, Zhiwei
    Wang, Wan
    FIRE TECHNOLOGY, 2017, 53 (01) : 65 - 86
  • [22] A review on mechanical behavior of laminated bamboo lumber connections
    Dauletbek, Assima
    Li, Haitao
    Lorenzo, Rodolfo
    COMPOSITE STRUCTURES, 2023, 313
  • [23] Punching Shear Behavior of Concrete Flat Slabs in Elevated Temperature and Fire
    Ghoreishi, Mehrafarid
    Bagchi, Ashutosh
    Sultan, Mohamed A.
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (05) : 659 - 674
  • [24] Flexural behavior of shallow cellular composite floor beams with innovative shear connections
    Chen, Shiming
    Limazie, Toi
    Tan, Jianyao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 106 : 329 - 346
  • [25] The Robustness of Steel Connections in Fire
    Burgess, Ian
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 103 - 111
  • [26] Mechanical Behavior of Natural Granite Residual Soil in Simple Shear
    Liu, Xinyu
    Miao, Yu
    Zhang, Xianwei
    Yin, Song
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2024, 150 (10)
  • [27] Thermal and Structural Response of Beam-end Shear Connections During a Large Compartment Fire Experiment
    Dai, Xu
    Choe, Lisa
    Fischer, Erica
    Clifton, G. Charles
    FIRE TECHNOLOGY, 2024, 60 (05) : 3175 - 3207
  • [28] Experimental study on behavior of top-and-seat-angle with double web-angle (TSDW) connections under fire conditions
    Cao, Yifan
    Lu, Yaoliang
    Jiang, Jian
    Chen, Wei
    Ye, Jihong
    THIN-WALLED STRUCTURES, 2024, 194
  • [29] Experimental and numerical studies on the behavior of high strength steel shear connections at elevated temperatures
    Wang, Weiyong
    Fang, Haojie
    Zhang, Linbo
    FIRE SAFETY JOURNAL, 2023, 139
  • [30] Research review: Post-earthquake fire assessment of steel buildings in the United States
    Chicchi, Rachel