Review of Research on the Fire Behavior of Simple Shear Connections

被引:12
|
作者
Fischer, Erica C. [1 ]
Chicchi, Rachel [2 ]
Choe, Lisa [3 ]
机构
[1] Oregon State Univ, Corvallis, OR 97331 USA
[2] Univ Cincinnati, Cincinnati, OH USA
[3] NIST, Gaithersburg, MD 20899 USA
关键词
Standard fire; Testing; Steel structures; Connections; FIN PLATE CONNECTIONS; COMPOSITE BEAMS; STEEL JOINT; TESTS;
D O I
10.1007/s10694-021-01105-1
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Previous building fires and research has shown that simple (shear) connections develop large axial force and flexural demands during a fire leading to potential failure of the connections and progressive collapse of a building. These findings have motivated decades of international research on the fire behavior of simple (shear) connections. While this research all confirmed that simple connections experience large axial force and flexural demands, it occurred without consistency of testing methodology, testing setup, and reporting of results. Due to this inconsistency, the decades of research have yet to be synthesized into comprehensive code changes for the design of simple connections in fires. This paper will summarize international experimental and numerical research on simple (shear) connections and highlight the inconsistencies between this research in an effort to motivate consistent testing and data reporting for future research developments.
引用
收藏
页码:1519 / 1540
页数:22
相关论文
共 50 条
  • [1] Review of Research on the Fire Behavior of Simple Shear Connections
    Erica C. Fischer
    Rachel Chicchi
    Lisa Choe
    Fire Technology, 2021, 57 : 1519 - 1540
  • [2] Component Modeling for Fire Behavior of Shear Tab Connections
    Gordon, James A.
    Fischer, Erica C.
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2023, 60 (03): : 129 - 154
  • [3] Fire behavior of composite beams with simple connections: Benchmarking of numerical models
    Fischer, Erica C.
    Varma, Amit H.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 111 : 112 - 125
  • [4] Fire resistance tests on timber beam-to-column shear connections
    Palma, Pedro
    Frangi, Andrea
    Hugi, Erich
    Cachim, Paulo
    Cruz, Helena
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2016, 7 (01) : 41 - 57
  • [5] Experimental Evaluation of the Fire Performance of Simple Connections
    Fischer, Erica C.
    Selden, Kristi L.
    Varma, Amit H.
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (02)
  • [6] Fire resilience of composite beams with simple connections: Parametric studies and design
    Fischer, Erica C.
    Varma, Amit H.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 128 : 119 - 135
  • [7] Simple beam connections in combined shear and tension
    Guravich, Susan J.
    Dawe, John L.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2006, 33 (04) : 357 - 372
  • [8] Behavior and design of single plate shear connections
    Astaneh-Asl, A
    Liu, J
    McMullin, KM
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (5-8) : 1121 - 1141
  • [9] The Role of Connections in the Response of Steel Frames to Fire
    Burgess, Ian
    Davison, John Buick
    Dong, Gang
    Huang, Shan-Shan
    STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 449 - 461
  • [10] Performance of Timber Connections Exposed to Fire: A Review
    C. Maraveas
    K. Miamis
    Ch. E. Matthaiou
    Fire Technology, 2015, 51 : 1401 - 1432