Comparison of the accuracy of a free 3D camera system with the Ariel performance system

被引:3
作者
Miranda-Oliveira, Paulo [1 ,2 ,3 ]
Branco, Marco [4 ,5 ]
Fernandes, Orlando J. [6 ]
Santos-Rocha, Rita [4 ,5 ]
机构
[1] Federacao Portuguesa Atletismo, Oeiras, Portugal
[2] Inst Politecn Santarem, Lab Invest Desporto & Saude, Unidade Fisiol & Biomecan Desporto, Escola Super Desporto Rio Maior, Santarem, Portugal
[3] Inst Politecn Leiria, Escola Super Tecnol Gestao, Leiria, Portugal
[4] Inst Politecn Santarem, Escola Super Desporto Rio Maior, Santarem, Portugal
[5] Univ Lisbon, CIPER, Fac Motricidade Humana, Cruz Quebrada Dafundo, Portugal
[6] Univ Evora, Dept Saude & Desporto, Comprehens Hlth Res Ctr CHRC, Evora, Portugal
关键词
Accuracy; reliability and motion analysis system; RELIABILITY;
D O I
10.1080/21681163.2021.1931963
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aims were: (1) to determine the accuracy and time-consuming of the automatic digitalization feature of 3D motion analysis systems; and (2) to determine the reliability of the 3D position when a football player performed a hard kick with spin. Four high-speed cameras (Casio ZR200 (512x384)) with a 240 Hz field rate were used. Automatic scanning of the Kinovea (R) and APAS (R) software was used. The accuracy was determined through mean absolute error, maximum absolute error, mean standard deviation of absolute error, and the variability values. The reliability was calculated with the Intra-Class Correlation. The mean absolute error (3.62 to 3.78 mm), maximum absolute error (9.09 to 11.61 mm), mean standard deviation of absolute error (0.01 to 0.59 mm), variability values (<1 mm), and the auto-digitalization time (16 to 31 minutes) were calculated and were within the values obtained in the literature. The reliability was determined with the Intra-Class Correlation, and the results were higher than 0.90, warrantied a high consistency for chosen software. The accuracy and the reliability intra-operator were determined, and the results indicated that it is possible to apply the free 3D camera system, with consistency in free-kick analysis.
引用
收藏
页码:670 / 677
页数:8
相关论文
共 19 条
[1]   Direct Linear Transformation from Comparator Coordinates into Object Space Coordinates in Close-Range Photogrammetry [J].
Abdel-Aziz, Y. I. ;
Karara, H. M. .
PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 2015, 81 (02) :103-107
[2]  
Brosseau L, 1997, Physiother Res Int, V2, P150
[3]   Human movement analysis using stereophotogrammetry - Part 2: Instrumental errors [J].
Chiari, L ;
Della Croce, U ;
Leardini, A ;
Cappozzo, A .
GAIT & POSTURE, 2005, 21 (02) :197-211
[4]   Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters [J].
de Leva, P .
JOURNAL OF BIOMECHANICS, 1996, 29 (09) :1223-1230
[5]   Comparison of the performance of 3D camera systems .2. [J].
Ehara, Y ;
Fujimoto, H ;
Miyazaki, S ;
Mochimaru, M ;
Tanaka, S ;
Yamamoto, S .
GAIT & POSTURE, 1997, 5 (03) :251-255
[6]  
Ehara Y., 1995, GAIT POSTURE, V3, P166, DOI [10.1016/0966-6362(95)99067-U, DOI 10.1016/0966-6362(95)99067-U]
[7]   Measuring small linear displacements with a three-dimensional video motion analysis system: Determining its accuracy and precision [J].
Everaert, DG ;
Spaepen, AJ ;
Wouters, MJ ;
Stappaerts, KH ;
Oostendorp, RAB .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (09) :1082-1089
[8]  
Fernandes O., 2011, PORTUGUESE J SPORT S, V29, P935
[9]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15
[10]   Reliability analysis of observational data: Problems, solutions, and software implementation [J].
Jansen, RG ;
Wiertz, LF ;
Meyer, ES ;
Noldus, LPJJ .
BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 2003, 35 (03) :391-399