A novel reduced field-of-view technique for cardiac MRI:: NoQuist

被引:1
|
作者
Moratal-Pérez, D [1 ]
Brummer, ME [1 ]
Hong, CY [1 ]
Pettigrew, RI [1 ]
Millet-Roig, J [1 ]
Dixon, WT [1 ]
机构
[1] Univ Politecn Valencia, ETSI Telecomunicac, Dpto Ing Elect, Valencia 46022, Spain
来源
COMPUTERS IN CARDIOLOGY 2002, VOL 29 | 2002年 / 29卷
关键词
D O I
10.1109/CIC.2002.1166693
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel cardiac magnetic resonance imaging (MRI) acceleration strategy called "NoQuist " is presented here. Using this new technique, a more sparsely sampled dynamic image sequence is correctly reconstructed without Nyquist foldover artifact by reductions in the size of the Fourier model of the k-space data for the dynamic image. It does not rely either on substitution or interpolation to. arrive at a data set sufficient for reconstruction of the dynamic sequence. The proposed "NoQuist" method allows reduction of acquisition time in dynamic MRI scans by eliminating the data redundancy that is associated with the presence of static regions in the dynamic scene. A reduction of acquisition time can be achieved, asymptotically equal to the tatic fraction of the field-of-view (FOV), by omitting acquisition of a strategically selected subset of phase encoding views from a conventional equidistant Cartesian acquisition grid.
引用
收藏
页码:5 / 8
页数:4
相关论文
共 50 条
  • [1] Noquist:: Reduced field-of-view imaging by direct Fourier inversion
    Brummer, ME
    Moratal-Pérez, D
    Hong, CY
    Pettigrew, RI
    Millet-Roig, J
    Dixon, WT
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 331 - 342
  • [2] Diffusion-weighted MRI of solid pancreatic lesions: Comparison between reduced field-of-view and large field-of-view sequences
    Donati, Francescamaria
    Casini, Chiara
    Cervelli, Rosa
    Morganti, Riccardo
    Boraschi, Piero
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 143
  • [3] Reduced circular field-of-view imaging
    Scheffler, K
    Hennig, J
    MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 474 - 480
  • [4] Reduced field-of-view diffusion-weighted MRI in patients with cervical cancer
    Hwang, Jiyoung
    Hong, Seong Sook
    Kim, Hyun-Joo
    Chang, Yun-Woo
    Nam, Bo Da
    Oh, Eunsun
    Lee, Eunji
    Cha, Hwajin
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1087):
  • [5] Reduced Field-Of-View Diffusion Weighted MRI On An MR-Guided Radiotherapy System
    Pham, J.
    Gao, Y.
    Low, D.
    Hu, P.
    Yang, Y.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Repeatability Study of Reduced Field-Of-View Diffusion-Weighted MRI On Human Thyroid Gland
    Shukla-Dave, A.
    Lu, Y.
    Hatzoglou, V.
    Banerjee, S.
    Stambuk, H.
    Shankaranarayanan, A.
    Mazaheri, Y.
    Deasy, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 463 - 463
  • [7] Gallbladder carcinoma: an initial clinical experience of reduced field-of-view diffusion-weighted MRI
    Wu, Sisi
    Zou, Xianlun
    Wang, Qiuxia
    Hu, Daoyu
    Li, Zhen
    Xu, Chuou
    CANCER IMAGING, 2020, 20 (01)
  • [8] Gallbladder carcinoma: an initial clinical experience of reduced field-of-view diffusion-weighted MRI
    Sisi Wu
    Xianlun Zou
    Qiuxia Wang
    Daoyu Hu
    Zhen Li
    Chuou Xu
    Cancer Imaging, 20
  • [9] A reduced field-of-view method to increase temporal resolution or reduce scan time in cine MRI
    Madore, B
    Fredrickson, JO
    Alley, MT
    Pelc, NJ
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (04) : 549 - 558
  • [10] Reduced field-of-view MRI using outer volume suppression for spinal cord diffusion imaging
    Wilm, B. J.
    Svensson, J.
    Henning, A.
    Pruessmann, K. P.
    Boesiger, P.
    Kollias, S. S.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 625 - 630