Fault location using the distributed parameter transmission line model

被引:111
|
作者
Gopalakrishnan, A [1 ]
Kezunovic, M
McKenna, SM
Hamai, DM
机构
[1] Texas A&M Univ, College Stn, TX 77843 USA
[2] Western Power Adm, Golden, CO USA
关键词
electromagnetic transients; fault location; modeling; synchronized sampling;
D O I
10.1109/61.891498
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Earlier work at Texas A&M University led to the development of transmission line fault location algorithms that were based on synchronized sampling of the voltage and current data from the two ends of the line. The Line models used in the algorithms were based on lumped parameter models for electrically short lines, or lossless distributed parameter models for electrically long lines, In this paper, the lossless line model is modified to account for the series losses in the line. The line model equations are then solved in the time domain to accurately locate the fault, Testing of the modified algorithm is performed on a power system belonging to the Western Area Power Administration. Extensive EMTP based simulations are used to generate data that are supplied as inputs to the fault location algorithm. To make the testing as realistic as possible, detailed models of instrument transformers are used in the simulation of the various fault cases.
引用
收藏
页码:1169 / 1174
页数:6
相关论文
共 50 条
  • [41] State Estimation Based Transmission Line Fault Locating With Sequence Distributed Parameter Models
    Liu, Yu
    An, Yiran
    Xie, Boqi
    2017 IEEE CONFERENCE ON ENERGY INTERNET AND ENERGY SYSTEM INTEGRATION (EI2), 2017,
  • [42] Phasor Domain Transmission Line Fault Locating with Three Phase Distributed Parameter Modeling
    Liu, Yu
    Tan, Zhenyu
    Xie, Jiahao
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [43] A Novel Fault Location Algorithmfor Double-Circuit Transmission Lines based on Distributed Parameter
    商立群
    施围
    电工电能新技术, 2006, (01) : 13 - 16+20
  • [44] Compacting distributed parameter transmission line model in EMTP-programs
    Paz, MA
    Tavares, MC
    Pissolato, J
    Portela, CM
    2004 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, 2004, : 196 - 200
  • [45] Phase distance protection of transmission line based on distributed parameter model
    Ma, J. (hdmajing@yahoo.com.cn), 1600, Electric Power Automation Equipment Press (32):
  • [46] Distance protection for HVDC transmission line based on distributed parameter model
    Suonan, Jiale
    Hou, Zhuo
    Song, Guobing
    Zhang, Jiankang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (08): : 53 - 57
  • [47] Fault Location on Transmission Line Using Maximum Correlation Coefficient Method
    Zheng, Zhong
    Liu, Jianyin
    Yu, Hong
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 226 - 229
  • [48] Travelling wave fault location of transmission line using wavelet transform
    Qin, J
    Chen, XX
    Zheng, JC
    POWERCON '98: 1998 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - PROCEEDINGS, VOLS 1 AND 2, 1998, : 533 - 537
  • [49] A transmission line fault-location system using the wavelet transform
    Hisakado, T
    Tanaka, K
    Okumura, K
    ELECTRICAL ENGINEERING IN JAPAN, 2002, 140 (04) : 27 - 37
  • [50] Transmission line fault detection and location using Wide Area Measurements
    Das, Sayari
    Singh, Shiv P.
    Panigrahi, Bijaya K.
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 151 : 96 - 105