Optimization and Comparative Performance Analysis of Conventional Air Conditioning System and Desiccant Air Conditioning System with Complete Waste Heat Reclamation: Experimental Investigation

被引:1
作者
Hussain, Taliv [1 ]
机构
[1] Aligarh Muslim Univ, Mech Engn Dept, Aligarh 202002, Uttar Pradesh, India
关键词
conventional air conditioning system; desiccant air conditioning system; humidity ratios; optimization and performance parameters; COOLING SYSTEM; DEHUMIDIFICATION; HOT;
D O I
10.18280/ijht.400113
中图分类号
O414.1 [热力学];
学科分类号
摘要
A desiccant air conditioning unit provides a compelling alternative to a conventional air conditioning system to eliminate moisture. In order to resolve the issue of more energy consumption for the regeneration of desiccant wheel, structures containing desiccant wheel can utilize full waste heat or thermal energy to restore desiccant material. Here, the performance of conventional and desiccant air conditioning systems have been evaluated. During experimentation, these two systems were operated and compared at process air inlet humidity ratios ranging (0.01580-0.01740 kg/kg) and process air inlet velocities ranging (1.5-4.5 m/s). Besides, the desiccant air conditioning system was regenerated by using complete waste heat from the condenser (50-58.8 degrees C) for regeneration of the desiccant wheel at a minimum (2.5 m/s) and a maximum (4.5 m/s) regeneration air inlet velocity. Thus, optimization of performance parameters, i.e. VCOP, ECOP, DCOP, wheel effectiveness in the adsorption sector and regeneration sector, adsorption rate and regeneration rate have been examined for achieving maximum efficiency of conventional and desiccant air conditioning systems under the above operating conditions.
引用
收藏
页码:105 / 120
页数:16
相关论文
共 25 条
[1]   Experimental study on a process design for adsorption desiccant cooling driven with a low-temperature heat [J].
Ando, K ;
Kodama, A ;
Hirose, T ;
Goto, M ;
Okano, H .
ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2005, 11 (Suppl 1) :631-636
[2]   Experimental assessment of the energy performance of a hybrid desiccant cooling system and comparison with other air-conditioning technologies [J].
Angrisani, Giovanni ;
Roselli, Carlo ;
Sasso, Maurizio .
APPLIED ENERGY, 2015, 138 :533-545
[3]   Experimental analysis on the dehumidification and thermal performance of a desiccant wheel [J].
Angrisani, Giovanni ;
Minichiello, Francesco ;
Roselli, Carlo ;
Sasso, Maurizio .
APPLIED ENERGY, 2012, 92 :563-572
[4]   Experimental investigation to optimise a desiccant HVAC system coupled to a small size cogenerator [J].
Angrisani, Giovanni ;
Minichiello, Francesco ;
Roselli, Carlo ;
Sasso, Maurizio .
APPLIED THERMAL ENGINEERING, 2011, 31 (04) :506-512
[5]  
[Anonymous], 2012, INTE J ENG RES DEV
[6]   Experimental investigation for performance enhancement of a vapor compression refrigeration system by employing several types of water-cooled condenser [J].
Ansari, Abdul Ahad ;
Goyal, Varun ;
Yahya, S. M. ;
Hussain, Taliv .
SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2018, 24 (07) :793-802
[7]  
BELGUITH S, 2020, INT RENEW ENERG CONG, pNIL42, DOI DOI 10.1109/irec48820.2020.9310373
[8]   Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning [J].
Dai, YJ ;
Wang, RZ ;
Zhang, HF ;
Yu, JD .
APPLIED THERMAL ENGINEERING, 2001, 21 (12) :1185-1202
[9]   Experimental investigation on a solid desiccant system integrated with a R407C compression air conditioner [J].
Fatouh, M. ;
Ibrahim, Talaat A. ;
Mostafa, A. .
ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (10) :2670-2679
[10]   Performance evaluation of solid desiccant wheel regenerated by waste heat or renewable energy [J].
Goodarzia, Gholamreza ;
Thirukonda, Neelesh ;
Heidari, Shahin ;
Akbarzadeh, Aliakbar ;
Date, Abhijit .
1ST INTERNATIONAL CONFERENCE ON ENERGY AND POWER, ICEP2016, 2017, 110 :434-439