Effect of efficient supply of pure O2 concentrated by PSA-type O2 separator on improvement of indoor air quality

被引:1
|
作者
Han, Gi Bo [1 ]
Jang, Jung Hee [1 ]
Choi, Changsik [1 ]
Lee, Tae Jin [2 ]
机构
[1] Inst Adv Engn, Plant Engn Div, 175-28,Goan Ro,51beon Gil, Yongin 17180, Gyeonggi Do, South Korea
[2] Yeungnam Univ, Sch Chem Engn, 214-1 Dae Dong, Gyongsan 38541, Gyeongbuk, South Korea
关键词
Indoor Air Quality; Room Ventilation System; Zeolite-based Adsorbent; O-2; Separator; Supply; PSA-type; OXYGEN-THERAPY; MODEL; SEOUL;
D O I
10.1007/s11814-015-0288-3
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
To minimize the cost and loss rate of energy artificial room ventilation system, the O-2 separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O-2 separated and concentrated by the O-2 separator can be supplied with the ventilation amount minimized. How the O-2 separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO2 and O-2. Consequently, it was known that the O-2 concentration was increased; however, the increase of the CO2 concentration was suppressed by the sufficient supply of O-2 concentrated from the storage tank into the room despite the two persons' breathing in the room having an inner volume of about 56 m(3). Consequently, it was concluded that the supply system of the concentrated O-2 which was stored into the tank after the production with the O-2 separator can be applied to the room ventilation system for the improvement of the indoor air quality.
引用
收藏
页码:1305 / 1310
页数:6
相关论文
共 50 条
  • [1] Effect of efficient supply of pure O2 concentrated by PSA-type O2 separator on improvement of indoor air quality
    Gi Bo Han
    Jung Hee Jang
    Changsik Choi
    Tae Jin Lee
    Korean Journal of Chemical Engineering, 2016, 33 : 1305 - 1310
  • [2] Performance test of PSA-type O2 separator for efficient O2 supply to room ventilation system combined with CO2 adsorption module
    Han, Gi Bo
    Jang, Jung Hee
    Lee, Tae Jin
    Choi, Changsik
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2016, 33 (04) : 1311 - 1317
  • [3] Performance test of PSA-type O2 separator for efficient O2 supply to room ventilation system combined with CO2 adsorption module
    Gi Bo Han
    Jung Hee Jang
    Tae Jin Lee
    Changsik Choi
    Korean Journal of Chemical Engineering, 2016, 33 : 1311 - 1317
  • [4] LOCAL O2 PRESSURE AS CRITERION FOR O2 SUPPLY OF SKELETAL MUSCLE
    KUNZE, K
    ARZNEIMITTEL-FORSCHUNG, 1971, 21 (03): : 369 - &
  • [5] Investigation of the collision-induced absorption by O2 near 6.4 μm in pure O2 and O2/N2 mixtures
    Maté, B
    Lugez, CL
    Solodov, AM
    Fraser, GT
    Lafferty, WJ
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2000, 105 (D17) : 22225 - 22230
  • [6] HYPERVENTILATION AND MYOCARDIAL O2 SUPPLY
    BUHLMANN, AA
    ANGEHRN, W
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1978, 108 (19) : 708 - 713
  • [7] Spin-orbit effect in the energy pooling reaction O2(a 1Δ)+O2(a 1Δ)→O2(b 1Σ)+O2(X 3Σ)
    Lu, Rui-Feng
    Zhang, Pei-Yu
    Chu, Tian-Shu
    Xie, Ting-Xian
    Han, Ke-Li
    JOURNAL OF CHEMICAL PHYSICS, 2007, 126 (12):
  • [8] ON FARADAY EFFECT IN O2
    FINKEL, J
    JOURNAL OF MOLECULAR SPECTROSCOPY, 1962, 9 (05) : 421 - &
  • [9] PURE STATE EXTENSIONS AND RESTRICTIONS IN O2
    LAZAR, A
    TSUI, SK
    WRIGHT, S
    JOURNAL OF OPERATOR THEORY, 1990, 23 (01) : 171 - 178
  • [10] Effect of low O2 on keeping quality of mangosteens
    Ratanachinakorn, B
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONTROLLED ATMOSPHERE RESEARCH CONFERENCE, VOLS I AND II, 2003, (600): : 747 - 750