Efficacy and Safety of Atrial Fibrillation Ablation Using Remote Magnetic Navigation: Experience from 1,006 Procedures

被引:18
作者
Jin, Qi [1 ,2 ]
Pehrson, Steen [1 ]
Jacobsen, Peter Karl [1 ]
Chen, Xu [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Ctr Heart, Dept Cardiol, DK-2100 Copenhagen, Denmark
[2] Shanghai Jiao Tong Univ, Dept Cardiol, Shanghai Rui Jin Hosp, Sch Med, Shanghai 200030, Peoples R China
关键词
atrial fibrillation; catheter ablation; remote magnetic navigation; CATHETER ABLATION; PERSISTENT; IMPACT; TRIAL;
D O I
10.1111/jce.12929
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
RMN-Guided Ablation for AF BackgroundThe objective of this study was to assess the procedural outcomes of catheter ablation guided by remote magnetic navigation (RMN) in a large cohort of patients with paroxysmalatrial fibrillation (PAF) andpersistentAF (PerAF). MethodsA total of 726 patients (547 male, age: 58.5 10.3 years) with symptomatic AF (61% PAF) were analyzed from a prospective ablation registry. Procedural parameters including pulmonary venous (PV) anatomy, left atrial (LA) volume, procedural time, ablation time, fluoroscopy time, total X-ray dose, and complications were assessed. ResultsOne thousand and six ablation procedures were analyzed. One-third of the patients (240/726) were ablated on more than one occasion, resulting in a mean of 1.3 +/- 0.6 times for the entire group. When analyzing all procedures, the mean procedural time and ablation time was 134 +/- 35 minutes and 2,130 +/- 1,025 seconds, respectively. The mean fluoroscopy time was 5.4 +/- 3.7 minutes. Compared to PAF patients, procedural time and ablation time were significantly increased in patients with PerAF by 10% (P<0.001) and 19% (P<0.001), respectively. However, fluoroscopy time was not increased (5.3 +/- 3.5 minutes, PAF vs. 5.6 +/- 4.0 minutes, PerAF, P = 0.17). The overall complication rate was 0.6%. One PAF patient experienced cardiac tamponade. AF repeat ablations by RMN significantly reduced the procedural and ablation times when compared with their first ablation times. ConclusionsAF ablation guided by RMN is safe as evidenced by a low complication rate. Fluoroscopy time was relatively short for both PAF and PerAF ablation.
引用
收藏
页码:S23 / S28
页数:6
相关论文
共 21 条
[1]   Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: Results from a multicenter study [J].
Bhargava, Mandeep ;
Di Biase, Luigi ;
Mohanty, Prasant ;
Prasad, Subramanyam ;
Martin, David O. ;
Williams-Andrews, Michelle ;
Wazni, Oussama M. ;
Burkhardt, J. David ;
Cummings, Jennifer E. ;
Khaykin, Yaariv ;
Verma, Atul ;
Hao, Steven ;
Beheiry, Salwa ;
Hongo, Richard ;
Rossillo, Antonio ;
Raviele, Antonio ;
Bonso, Aldo ;
Themistoclakis, Sakis ;
Stewart, Kelly ;
Saliba, Walid I. ;
Schweikert, Robert A. ;
Natale, Andrea .
HEART RHYTHM, 2009, 6 (10) :1403-1412
[2]   Catheter Ablation Utilizing Remote Magnetic Navigation: A Review of Applications and Outcomes [J].
Bradfield, Jason ;
Tung, Roderick ;
Mandapati, Ravi ;
Boyle, Noel G. ;
Shivkumar, Kalyanam .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (08) :1021-1034
[3]  
Calkins H, 2012, HEART RHYTHM, V9, P632, DOI 10.1016/j.hrthm.2011.12.016
[4]   Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation [J].
Cappato, R ;
Negroni, S ;
Pecora, D ;
Bentivegna, S ;
Lupo, PP ;
Carolei, A ;
Esposito, C ;
Furlanello, F ;
De Ambroggi, L .
CIRCULATION, 2003, 108 (13) :1599-1604
[5]   Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation [J].
Cappato, Riccardo ;
Calkins, Hugh ;
Chen, Shih-Ann ;
Davies, Wyn ;
Iesaka, Yoshito ;
Kalman, Jonathan ;
Kim, You-Ho ;
Klein, George ;
Natale, Andrea ;
Packer, Douglas ;
Skanes, Allan ;
Ambrogi, Federico ;
Biganzoli, Elia .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) :32-38
[6]   Catheter ablation for atrial fibrillation: results from the first European Snapshot Survey on Procedural Routines for Atrial Fibrillation Ablation (ESS-PRAFA) Part II [J].
Chen, Jian ;
Dagres, Nikolaos ;
Hocini, Melece ;
Fauchier, Laurent ;
Bongiorni, Maria Grazia ;
Defaye, Pascal ;
Hernandez-Madrid, Antonio ;
Estner, Heidi ;
Sciaraffia, Elena ;
Blomstrom-Lundqvist, Carina .
EUROPACE, 2015, 17 (11) :1727-1732
[7]   Comparison of Magnetic Navigation System and Conventional Method in Catheter Ablation of Atrial Fibrillation: Is Magnetic Navigation System Is More Effective and Safer Than Conventional Method? [J].
Choi, Min Seok ;
Oh, Yong-Seog ;
Jang, Sung Won ;
Kim, Ji Hoon ;
Shin, Woo Seung ;
Youn, Ho-Joong ;
Jung, Wook Sung ;
Lee, Man Young ;
Seong, Ki Bae .
KOREAN CIRCULATION JOURNAL, 2011, 41 (05) :248-252
[8]   Atrial fibrillation ablation using remote magnetic navigation and the risk of atrial-esophageal fistula: international multicenter experience [J].
Danon, Asaf ;
Shurrab, Mohammed ;
Nair, Krishnakumar Mohanan ;
Latcu, Decebal Gabriel ;
Arruda, Mauricio S. ;
Chen, Xu ;
Szili-Torok, Tamas ;
Rossvol, Ole ;
Wissner, Eric E. ;
Lashevsky, Ilan ;
Crystal, Eugene .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 43 (02) :169-174
[9]   Magnetic guidance system for cardiac electrophysiology - A prospective trial of safety and efficacy in humans [J].
Faddis, MN ;
Chen, J ;
Osborn, J ;
Talcott, M ;
Cain, ME ;
Lindsay, BD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1952-1958
[10]  
January CT, J Am Coll