Exceedance Degree-Hours: A new method for assessing long-term thermal conditions

被引:9
作者
Salimi, Shide [1 ,2 ]
Estrella Guillen, Esteban [3 ]
Samuelson, Holly [1 ]
机构
[1] Harvard Grad Sch Design, Cambridge, MA 02138 USA
[2] Harvard Ctr Green Bldg & Cities, Cambridge, MA USA
[3] Univ Monterrey, San Pedro Garza Garcia, NL, Mexico
基金
加拿大自然科学与工程研究理事会;
关键词
adaptive comfort; building performance; equivalent temperature sensation; Fanger comfort; indoor environmental quality; thermal comfort index; RESIDENTIAL BUILDINGS; COMFORT MODELS; TEMPERATURE; ENVIRONMENT; HUMIDITY; CLIMATE; SIMULATION; INDEX; REQUIREMENTS; ADAPTATION;
D O I
10.1111/ina.12855
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Several "discomfort indices" have been proposed and codified into building standards, with several needs usually reported for such indices. They should: express the severity of discomfort in time steps while incorporating all environmental and personal factors; be usable with any comfort model (and thus, a variety of interests, for example, traditional thermal comfort, sleep comfort), among other requirements. The existing indices, however, fall short of meeting all these goals, limiting their usefulness in many situations, such as assessing conditions in mixed-mode buildings, especially when used for building performance simulation and design optimization purposes. Here, a new discomfort index called "Exceedance Degree-Hours" is developed, which accounts for all six main environmental and personal factors. By using an equivalent temperature index, "Exceedance Degree-Hours" can capture variations in discomfort severity between different thermal conditions that other indices cannot. In contrast with other indices, "Exceedance Degree-Hours" can be paired with various comfort definitions from literature, and, importantly, it can be used to assess thermal comfort in mixed-mode buildings, providing a single value as a result. Here, the results of the proposed method are compared to those of existing discomfort indices suggested in standards, and the advantages and limitations of the proposed approach are discussed.
引用
收藏
页码:2296 / 2311
页数:16
相关论文
共 63 条
  • [1] Aduralere T., PASSIVE SURVIVABILIT, V7
  • [2] Thermal Environment Assessment Reliability Using Temperature -Humidity Indices
    Alfano, Francesca Romana d'Ambrosio
    Palella, Boris Igor
    Riccio, Giuseppe
    [J]. INDUSTRIAL HEALTH, 2011, 49 (01) : 95 - 106
  • [3] [Anonymous], 2009, The Universal Thermal Climate Index (UTCI) for Assessing the Thermal Environment of the Human Being - COST Action 730 Executive Summary
  • [4] [Anonymous], 2007, 15251 EN
  • [5] ASHRAE 55, 2017, 55 ASHRAE, P155
  • [6] Impact of different thermal comfort models on zero energy residential buildings in hot climate
    Attia, Shady
    Carlucci, Salvatore
    [J]. ENERGY AND BUILDINGS, 2015, 102 : 117 - 128
  • [7] Climate change, humidity, and mortality in the United States
    Barreca, Alan I.
    [J]. JOURNAL OF ENVIRONMENTAL ECONOMICS AND MANAGEMENT, 2012, 63 (01) : 19 - 34
  • [8] Comfort standards and variations in exceedance for mixed-mode buildings
    Borgeson, Sam
    Brager, Gail
    [J]. BUILDING RESEARCH AND INFORMATION, 2011, 39 (02) : 118 - 133
  • [9] Occupant satisfaction in mixed-mode buildings
    Brager, Gail
    Baker, Lindsay
    [J]. BUILDING RESEARCH AND INFORMATION, 2009, 37 (04) : 369 - 380
  • [10] Thermal adaptation in the built environment: a literature review
    Brager, GS
    de Dear, RJ
    [J]. ENERGY AND BUILDINGS, 1998, 27 (01) : 83 - 96