Comparison of measurement systems for assessing number- and mass-based particle filtration efficiency

被引:9
作者
Sipkens, Timothy A. [1 ]
Corbin, Joel C. [1 ]
Koukoulas, Triantafillos [1 ]
Oldershaw, Andrew [1 ]
Lavoie, Thierry [1 ]
Oliaee, Jalal Norooz [1 ]
Liu, Fengshan [1 ]
Leroux, Ian D. [1 ]
Smallwood, Gregory J. [1 ]
Lobo, Prem [1 ]
Green, Richard G. [1 ]
机构
[1] Natl Res Council Canada, Metrol Res Ctr, Ottawa, ON, Canada
关键词
Particle filtration efficiency; particle size; particle size distribution; PPE; respiratory protection; respiratory standards; FILTER PENETRATION; N95; RESPIRATORS; PERFORMANCE;
D O I
10.1080/15459624.2022.2114596
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The particle filtration efficiency (PFE) of a respirator or face mask is one of its key properties. While the physics of particle filtration results in the PFE being size-dependent, measurement standards are specified using a single, integrated PFE, for simplicity. This integrated PFE is commonly defined concerning either the number (NPFE) or mass (MPFE) distribution of particles as a function of size. This relationship is non-trivial; it is influenced by both the shape of the particle distribution and the fact that multiple practical definitions of particle size are used. This manuscript discusses the relationship between NPFE and MPFE in detail, providing a guide to practitioners. Our discussion begins with a description of the theory underlying different variants of PFE. We then present experimental results for a database of size-resolved PFE (SPFE) measurements for several thousand candidate respirators and filter media, including filter media with systematically varied properties and commercial samples that span 20%-99.8% MPFE. The observed relationships between NPFE and MPFE are discussed in terms of the most-penetrating particle size (MPPS) and charge state of the media. For the sodium chloride particles used here, we observed that the MPFE was greater than NPFE for charged materials and vice versa for uncharged materials. This relationship is observed because a shift from NPFE to MPFE weights the distribution toward larger sizes, while charged materials shift the MPPS to smaller sizes. Results are validated by comparing the output of a pair of automated filter testers, which are used in gauging standards compliance, to that of MPFE computed from a system capable of measuring SPFE over the 20 nm-500 nm range.
引用
收藏
页码:629 / 645
页数:17
相关论文
共 62 条
[1]   A rapid review of the use of face mask in preventing the spread of COVID-19 [J].
Abboah-Offei, Mary ;
Salifu, Yakubu ;
Adewale, Bisi ;
Bayuo, Jonathan ;
Ofosu-Poku, Rasheed ;
Opare-Lokko, Edwina Beryl Addo .
INTERNATIONAL JOURNAL OF NURSING STUDIES ADVANCES, 2021, 3
[2]   Filtration efficiency, breathability, and reusability of improvised materials for face masks [J].
Bagheri, Morteza H. ;
Khalaji, Iman ;
Azizi, Arad ;
Loibl, Rebecca T. ;
Basualdo, Natalia ;
Manzo, Scott ;
Gorrepati, Madhu L. ;
Mehendale, Shilpa ;
Mohr, Catherine ;
Schiffres, Scott N. .
AEROSOL SCIENCE AND TECHNOLOGY, 2021, 55 (07) :817-827
[3]   Do N95 respirators provide 95% protection level against airborne viruses, and how adequate are surgical masks? [J].
Balazy, A ;
Toivola, M ;
Adhikari, A ;
Sivasubramani, SK ;
Reponen, T ;
Grinshpun, SA .
AMERICAN JOURNAL OF INFECTION CONTROL, 2006, 34 (02) :51-57
[4]   Aerosol loading performance of electret filter media [J].
Barrett, LW ;
Rousseau, AD .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1998, 59 (08) :532-539
[5]   A guideline to limit indoor airborne transmission of COVID-19 [J].
Bazant, Martin Z. ;
Bush, John W. M. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (17)
[6]  
BEMENT T, AEROSOL AIR QUAL RES, V22
[7]   FILTER PENETRATION MEASUREMENTS USING A CONDENSATION NUCLEI COUNTER AND AN AEROSOL PHOTOMETER [J].
BIERMANN, AH ;
BERGMAN, W .
JOURNAL OF AEROSOL SCIENCE, 1988, 19 (04) :471-483
[8]  
Bohren C. F., 2008, ABSORPTION SCATTERIN
[9]   Disposable masks: Disinfection and sterilization for reuse, and non-certified manufacturing, in the face of shortages during the COVID-19 pandemic [J].
Carlos Rubio-Romero, Juan ;
del Carmen Pardo-Ferreira, Maria ;
Antonio Torrecilla-Garcia, Juan ;
Calero-Castro, Santiago .
SAFETY SCIENCE, 2020, 129
[10]   Immediate-use steam sterilization sterilizes N95 masks without mask damage [J].
Carrillo, Irene O. ;
Floyd, Anna C. E. ;
Valverde, Christian M. ;
Tingle, Travis N. ;
Zabaneh, Firas R. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2020, 41 (09) :1104-1105